• Title/Summary/Keyword: color software

Search Result 450, Processing Time 0.029 seconds

Single Image Based HDR Algorithm Using Statistical Differencing and Histogram Manipulation (통계적 편차와 히스토그램 변형을 이용한 단일영상기반 고품질 영상 생성기법)

  • Song, Jin-Sun;Han, Kyu-Phil;Park, Yang-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.7
    • /
    • pp.764-771
    • /
    • 2018
  • In this paper, we propose a high-quality image acquisition algorithm using only a single image, which the high-quality image is normally referred as HDR ones. In order to acquire the HDR image, conventional methods need many images having different exposure values at the same scene and should delicately adjust the color values for a bit-expansion or an exposure fusion. Thus, they require considerable calculations and complex structures. Therefore, the proposed algorithm suggests a completely new approach using one image for the high-quality image acquisition by applying statistical difference and histogram manipulation, or histogram specification, techniques. The techniques could control the pixel's statistical distribution of the input image into the desired one through the local and the global modifications, respectively. As the result, the quality of the proposed algorithm is better than those of conventional methods implemented in commercial image editing softwares.

K-Viz: KEGG Based Bisualization for Comparing Metabolic Pathways (K-Viz : 대사 경로 비교를 위한 KEGG 기반의 시각화)

  • Im, Dong-Hyuk;Lee, Dong-Hee;Kim, Hyoung-Joo
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.5
    • /
    • pp.389-396
    • /
    • 2007
  • The comparison of metabolic pathway in different species is important in detecting a missing gene. There are many visualizations for metabolic pathway. However, Biologists need not only a simple path but also a visualization for comparison. K-Viz is a tool for visualization of metabolic pathway based on KEGG. To compare pathways in different species, K-Viz uses different color for path such as PathComp in KEGG and shows the table of path in pathway. K-Viz helps biologists to understand the comparison of metabolic pathways in different species.

Computer Simulation for the Cavitation Changes at the Exit of Offset Printing Nip (오프셋 인쇄의 틈새출구에서 공동의 변화에 대한 시뮬레이션)

  • Youn, Jong-Tae;Kim, Yun-Taek;Lim, Soo-Man
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • Offset paper printing is a promising roll-to-roll technique for color printed materials. Although it is no doubt that understanding ink transfer mechanism in offset printing process is necessary to achieve high printing quality, investing the relationship between inks and substrates at the nip is difficult experimentally due to high printing speed. In this paper, rheological behavior and splitting point of the ink at the nip is studied using package software Ployflow and Flow 3D based on Navier-Stokes equation. Polydimethylsiloxane (PDMS) ink and IGT printability tester were used for an model ink and experiment to compare with that of simulation data, respectively. As a result, higher viscosity at state flow and pressure increased ink transfer due to higher possibility of presence of cavitation at the nip and increase in covering area ratio. These results have shown good agreements with experimental data compared by measuring density of print through.

Implementing Graphic User Interface System for Microwave Radiometry Data to Utilize Breast Cancer Diagnosis (유방암 진단 활용을 위한 마이크로파 라디오미터 측정 데이터의 GUI 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Jeong-Whan;Han, Jong-Sam;Heo, Kyou-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.818-824
    • /
    • 2013
  • In this study, a novel Graphic User Interface (GUI) software development system is suggested so that it can be applied to diagnose breast cancer with utilizing 3~4.2 GHz microwave radiometric data. The estimated inner and surface temperature values on the patient's right and left breast in terms of microwave radiometry are visualized in HSV color mapping space and their relevant contour regions and lines are depicted by Marching Square graphic algorithm. Also the database system is implemented in terms of patient and diagnostic module to support the medical decisions concerning the breast cancer diagnosis.

Survey on Quantitative Performance Evaluation Methods of Image Dehazing (안개 제거 기술의 정량적인 성능 평가 기법 조사)

  • Lee, Sungmin;Yu, Jae Taeg;Jung, Seung-Won;Ra, Sung Woong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.12
    • /
    • pp.571-576
    • /
    • 2015
  • Image dehazing has been extensively studied, but the performance evaluation method for dehazing techniques has not attracted significant interest. This paper surveys many existing performance evaluation methods of image dehazing. In order to analyze the reliability of the evaluation methods, synthetic hazy images are first reconstructed using the ground-truth color and depth image pairs, and the dehazed images are then compared with the original haze-free images. Meanwhile we also evaluate dehazing algorithms not by the dehazed images' quality but by the performance of computer vision algorithms before/after applying image dehazing. All the aforementioned evaluation methods are analyzed and compared, and research direction for improving the existing methods is discussed.

A study on Electromagnetic Propertie of the Ring-shaped electrodeless fluorescent lamp (동근형 무전극 형광램프의 전자계 특성)

  • Lee, Seong-Jin;Kim, Nam-Kun;Park, No-Jun;Lee, Jong-Chan;Jung, Young-II;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.220-221
    • /
    • 2006
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved Quality of the lighting space. Above all, the advantages of ring-shaped electrodeless fluorescent lamp are the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps last up to 60,000 hours, There are intended as a highly efficient replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 kHz and some specific conditions. In addition, the optical characteristics of ring-shaped electrodeless fluorescent lamp were measured including light flux, efficiency and color temperature for each case.

  • PDF

A quantitative measurement of concrete air content using image analyses

  • Hwang, C.L.;Peng, S.S.;Wang, E.;Lin, S.H.;Huang, S.L.
    • Computers and Concrete
    • /
    • v.7 no.3
    • /
    • pp.239-247
    • /
    • 2010
  • A proposed topology method is introduced to measure the air content of fresh cement paste and hardened concrete. The method takes advantage of chromatographic analysis in void areas that are highlighted using different color schemes and later calculated using built-in computer software. The air content measured by the topology method is compared with results obtained from the conventional ASTM methods. It is concluded that the proposed method is reliable, and costs less and is easier to operate compared with the ASTM methods. In addition, 3 dimensional pore models can be created using image post-processing techniques. The proposed method helps researchers in understanding the formation and existence of concrete pores. This paper reports a detailed test program demonstrating the standard operating procedure used for the proposed method and presents a comparison of results between the proposed method and conventional ASTM Specifications. It is also concluded that the air content increases with increasing size of pores and increasing percentage of coarse aggregates.

THE STUDY ON THE TOPOGRAPHIC VARIATIONS OF FACIAL SKIN IN KOREAN ADULT FEMALES

  • Cho, Joon-Hwan;Ju-An. Yun;Ha, Jae-Hyon;Cho, Youn-Ki
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.424-437
    • /
    • 2003
  • This study was observed the variations in skin color, hydration, sebum content according to age groups at the forehead, both cheeks, and chin in 154 healthy Korean women subjects with aged 30 to 59. We selected four face sites (forehead, right cheek, left cheek, and chin) and measured with chromameter, corneometer, and sebumeter. All statistical analysis was performed on the computer software package SPSS 8.0. There was no significant difference of lightness between facial four regions in age groups but lightness showed to tend to age-related decrease on each regions. Redness and yellowness showed the highest values on chin and forehead respectively but there was no tendency to steady changes according to age variation. Both cheeks showed the highest hydration level and the lowest sebum content compared with forehead and chin in all age groups and there was tendency to age-related changes of sebum content on both cheeks. So we concluded there was decreasing tendency in lightness and sebum content according to the increase of age and there was no age-related change of skin hydration level at least in facial skin.(omitted)

  • PDF

Quality assessment of high performance concrete using digitized image elements

  • Peng, Sheng-Szu;Wang, Edward H.;Wang, Her-Yung;Chou, Yu-Te
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.409-417
    • /
    • 2012
  • The quality of high performance concrete largely depends on water cement ratio, porosity, material composition and mix methods. The uniformity of color, texture and compressive strengths are quality indicators commonly used to assess the overall characteristics of concrete mixes. The homogeneity and share of coarse aggregates play a key role in concrete quality and must be analyzed in a microscopic point of view. This research studies the quality of high performance concrete by taking drilled cores in both horizontal and vertical directions from a 1.0 $m^3$ specimen. The coarse aggregate, expressed in digitized $100{\times}116$ dpi resolution images are processed based on brightness in colors through commercial software converted into text files. With the image converting to text format, the share of coarse aggregate is quantified leading to a satisfactory assessment of homogeneity - a quality index of high performance concrete. The compressive strengths of concrete and the shares of coarse aggregate of the samples are also compared in this research study to illustrate its correlation in concrete quality. It is concluded that a higher homogeneity of aggregate exists in the vertical plane than that of the horizontal planes of the high performance concrete. In addition, the concrete specimen showing denser particle packing has relatively higher compressive strengths. The research methodology provides an easy-to-use, direct measurement of high performance concrete when conducting quality assessment in the construction site.

Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber (유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가)

  • Kim, Dong-Yeon;Yang, Cheon-Seung;Lee, Gwang-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type IV stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 ㎛ and that of fiberglass resin was 224.92 ㎛. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.