• Title/Summary/Keyword: color lens

Search Result 158, Processing Time 0.027 seconds

POLYGONIOSCOPE a new instrument for fastest luminance, color and viewing angle measurement with highest accuracy

  • Laur, Juergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1370-1373
    • /
    • 2008
  • This paper introduces a novel display measuring instrument that allows accurate, spectro-radiometric measurement of the complete viewing cone while the measuring time is similar to that of a CCD camera with transform lens optics. Actually the new instrument, named POLYGONIOSCOPE, is orders of magnitude faster compared to a conventional spot spectrometer.

  • PDF

Get Color Image That Using Monochrome CCD Camera and Color Filter, and Color Revision (Monochrome-Camera와 Color-Filter를 이용한 Color Image획득과 색상보정)

  • Kwon O. S.;Park Y. C.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.329-334
    • /
    • 2005
  • Most people are using a Color-CCD-Camera in other to acquire a color image. But we are getting a color image with the Monochrome-CCD-Camera equipped for Rotation-Color-Filter in front of the camera lens. The Monochrome CCD Camera has some advantages such as the low price. In addition Rotation-Color-Filter's design is very simple. So we can make this structure easily and economically. In this paper, we described how to make a color image from Monocrome-Camera and correcting color well.

  • PDF

Optical System Design for Projection TV using Micro Display (마이크로 디스플레이를 이용한 프로젝션 TV용 광학계 설계)

  • Park, Sung-Chan;Lee, Jung-Yul
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.240-247
    • /
    • 2006
  • This paper discusses the optical system design for projection TV using LCOS type micro display, which provides the high resolution, slim depth, and a large screen of more than 60 inches. We analyzed the relationship between the illumination system, projection lens, color separation & recombination system, and micro display. From this quantitative analysis, the starting data for the optimum light engine was defined, and all optical systems were designed by an optimization process. Three RGB panels were proposed for a high luminence system, and the four prisms symmetrically located make equal optical path lengths for the RGB rays. This color separation & recombination system enables the a compact illumination system. Also, in order to the slim light engine with high resolution, the folded projection lens system was designed by inserting a mirror between projection lenses.

The Change of the Phoria in Accordance with the Color and Concentration of the Color Lens (착색렌즈의 색상과 농도에 따른 원거리 사위도의 변화)

  • Choi, Hyun-Soo;Park, Sung-Jong;Lee, Seok-Ju;Jin, Moon-Seok;Jun, Jin;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.339-343
    • /
    • 2011
  • Purpose: In this study, we investigated changes of phoria based on varying the color and concentration of the color in lenses. Methods: We measured distance phoria for 39 students who aged 20 to 40 with different concentrated lenes - red, gray, brown and green lenses in concentration 20%, 50% and 80%, respectively. Results: Subjects were divided into three groups which were orthophoria, esophoria and exophoria. Orthophoria in all the color and concentration, there were a few of the esophoria. Esophoria of average 2.07${\Delta}$,B.O showed that a slight increase in all colors and concentration, especially in brown lenses showed the greatest increase. Exophoria of average 3.82${\Delta}$,B.I showed that a slight decrease in all colors and concentration, especially in green lenses showed to 2.95${\Delta}$,B.I to the greatest decrease. Different concentration in same color had no specific tendency regarding phoria. Conclusions: The phoria must be considered when selecting color of the lens because of phoria is changeable by color of the lens. It is expected to study the criteria that minimize the asthenopia.

The Reflection Color Light with the Structure of an Antireflection Lenses (렌즈 무반사막 구조에 의한 반사색광의 특성 연구)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.93-102
    • /
    • 1996
  • The optical system of lens must be designed to tramsmit light over wide wavelength range and to have lower reflectivity in order to obtain higher spectral transmittance. However, the reflection color light appears due to the remain-reflection light in any optical system of lens. The wavelength of the reflection color light can be controlled by the structure of the number of layers, thickness of layer, reflective index, wavelength of incidence, and substrate etc. In the optical systems of the single layer and the double layers, the reflection color light appears in the condition of the anti-reflection of ${\lambda}s/{\lambda}$ = 1.0 by the color mixture of the remain-reflection lights in the ranges of the longer wavelength side and the shorter one of the ${\lambda}s/{\lambda}$ = 1.0, and of the double layers and triple layers, the reflection color light positioned at P1 < ${\lambda}s/{\lambda}$ < P2 appears in the condition of the antireflection of ${\lambda}s/{\lambda}$ = $PI{\ll}1$ and $P2{\gg}1$. In the optical system of the multi-layers, many antireflection points are existed at the various s/ values, and the reflection color light by the color mixture of the remain-reflection lights in the ranges except for the antireflection points.

  • PDF

Optimization of Cutoff Shields in Projection Headlight Systems to Achieve High Intensity Gradient and Low Color Separation at the Cutoff Line

  • Joo, Byung-Yun;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.118-124
    • /
    • 2016
  • The shape and location of the cutoff shield in a projection-type headlight system were optimized by a ray-tracing technique. A shield based on a Petsval surface showed better cutoff characteristics than a flat or cylindrical shield, such as a sharp intensity gradient and less color separation at the cutoff line. Adjustment of the shield’s location between the reflector and the aspheric lens further improved its cutoff characteristics.

New analysis method of electrostatic lens for CRT

  • Seok, J.M.;Ham, Y.S.;Lee, J.I.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.395-398
    • /
    • 2002
  • The spherical aberration and optical integer (f) of the electron gun's main lens in color CRT is obtained, using electron beam trajectory. A spherical aberration is obtained from the relation between the object plane and the image of a beam trajectory. To analyze beam profile, 3rd and 1st order coefficient were obtained and used. It is shown that, in practice, they are applied to electron gun design.

  • PDF

Evaluation of Vision-Specific Quality of Life between Spectacles and Contact Lens Wearers (안경과 콘택트렌즈착용자의 삶의 질 평가)

  • Kang, Sue Ah;Kim, Jung Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • Purpose: The aim of this study was to assess vision-related quality of life and modes of refractive error correction. We administered NEI-VFQ (National Eye Institute Visual Function Questionnaire) to 137 subjects in two modes of refractive error correction: spectacles and contact lens wearers. The NEL-VFQ was developed to assess vision-related quality of life with respect to 1) visual symptoms 2) social function as well as difficulty with tasks and symptoms 3) economic issues and health concerns 4) psychological well-being. The NEL-VFQ was translated from English into Korean. Methods: All data were analyzed using SAS 8.0. Student's T-test was conducted to determine significant differences in each of the subscale (${\alpha}=0.05$). Result: The Peripheral Vision subscale score ($mean{\pm}SD$) was $52.2{\pm}32.7$ for the spectacle wearers, $88.6{\pm}18.1$ for contact lens wearers; the spectacle wearers' Peripheral Vision score was significantly lower than contact lens wearers (p=0.0001). There were also significant differences between two groups detected in Color Vision (p=0.001), General Vision (p=0.01) and Health Perception (p=0.01). Conclusion: Contact lens wearers and spectacle wearers were mostly high vision-related quality of life except General Vision and Health Perception. Especially, contact lens wearers were higher vision-related quality of life than spectacle wearers. Further studies on developing of good quality of contact lens will be needed to improve quality of life in ametropia.

  • PDF

The real-time three-dimensional shape measurement by prism lens (프리즘 광학계를 이용한 실시간 삼차원 형상 측정)

  • Kim J.S.;Song C.K.;Joo B.K.;Hong J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.727-731
    • /
    • 2005
  • We introduce a method of color-coded illumination that is simple and fast. The purpose of this study is the real-time shape measurement of three-dimensional object by using color-coded information. The object is illuminated by a prism color spectrum. A color spectrum of a white-light source is imaged onto the object by illumination from one certain direction. The object is observed by a color CCD camera from a direction of observation, which is different from the direction of illumination. It can be evaluated by the red, blue, green using a inherence colors of hue value are good point.

  • PDF

A Study on Effective Stitching Technique of 360° Camera Image (360° 카메라 영상의 효율적인 스티칭 기법에 관한 연구)

  • Lee, Lang-Goo;Chung, Jean-Hun
    • Journal of Digital Convergence
    • /
    • v.16 no.2
    • /
    • pp.335-341
    • /
    • 2018
  • This study is a study on effective stitching technique for video recorded by using a dual-lens $360^{\circ}$ camera composed of two fisheye lenses. First of all, this study located a problem in the result of stitching by using a bundled program. And the study was carried out, focusing on looking for a stitching technique more efficient and closer to perfect by comparatively analyzing the results of stitching by using Autopano Video Pro and Autopano Giga, professional stitching program. As a result, it was shown that the problems of bundled program were horizontal and vertical distortion, exposure and color mismatch and unsmooth stitching line. And it was possible to solve the problem of the horizontal and vertical by using Automatic Horizon and Verticals Tool of Autopano Video Pro and Autopano Giga, problem of exposure and color by using Levels, Color and Edit Color Anchors and problem of stitching line by using Mask function. Based on this study, it is to be hoped that $360^{\circ}$ VR video content closer to perfect can be produced by efficient stitching technique for video recorded by using dual-lens $360^{\circ}$ camera in the future.