The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

Light Output Characteristics of Rounded Prism Films in the Backlight Unit for Liquid Crystal Display

  • Lee, Won-Gyu;Jeong, Jin-Ha;Lee, Ji-Young;Nahm, Kie-Bong;Ko, Jae-Hyeon
    • Journal of Information Display
    • /
    • 제7권4호
    • /
    • pp.1-4
    • /
    • 2006
  • The optical performances of rounded prism films were investigated using a ray tracing technique. The angular distribution of the luminous intensity was obtained as functions of the prism pitch and the curvature of rounded apex and valley of prism arrays. The gain of the on-axis luminance decreased with decreasing curvature (increasing diameter) and pitch. The existence of the curved area on the prism film decreased the recycling efficiency of the prism film, i.e., the rays which would otherwise have been recycled through total internal reflections via the prism surfaces were refracted on the curved regions and redirected toward directions other than the on-axis direction. Quantitative correlation between the luminance gain and the curvature in addition to the prism pitch was obtained, which might serve as basic data for the optimization of prism films and the manufacturing processes.

Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안 (Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System)

  • 동경래;최준구;홍성일
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.145-155
    • /
    • 2009
  • CR방식의 도입으로 인해 많은 장점을 가지게 되었으나 기존의 Film/Screen방식에서 발생되지 않았던 Artifact가 새롭게 발생하였다. 따라서 본 논문에서는 광주에 위치한 일개 종합병원에서 획득한 CR 영상 중 Artifact가 발생한 경우를 3가지로 나누어 측정하였다. 시간 지연과 농도변화에 의한 Artifact는 시간이 경과할수록 자연방사선에 의한 영향으로 1일보다 5일후에 67%의 농도가 증가 되었으며 잠상퇴행에 의한 Artifact는 즉시보다 10시간 후의 빛의 방출도가 33%감소하여 시판이 경과할수록 영상의 질이 저하되었다. 술자에 의한 Artifact는 Collimation에 의한 Artifact가 53%, 기기에 의한 Artifact는 Guiding plate, Suction cup으로 인한 Artifact가 65%로 가장 많이 발생되는 것으로 나타났다. 따라서 Artifact에 대한 정확한 인식을 정기적인 점검을 통해 해결방안을 모색한다면 영상의 질 및 진료의 만족도를 높여 갈 수 있을 것이다.

Optical Simulation Study on the Effect of Reflecting Properties of Reflection Films on the Performances of Collimating Films for the LCD Backlight Applications

  • Lee, Jeong-Ho;Ju, Young-Hyun;Park, Ji-Hee;Lee, Ji-Young;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Journal of Information Display
    • /
    • 제9권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The dependence of optical performances of collimating films such as prism films and pyramid films on the reflecting properties of reflection films were investigated by using a ray tracing technique. The angular distribution of the luminance and the on-axis luminance gain were obtained by using a simple backlight model composed of a reflection film, a virtual flat light source, and a collimating film. Three kinds of reflecting properties were used, which were a perfect Lambertian reflector, a perfect mirror reflector, and a reflector having both diffuse and specular properties. It was found that the on-axis luminance gain was the highest in the simulation where a mirror reflector was used, while the viewing angle was the widest where the Lambertian reflector was used. This result indicates that it is necessary to optimize the simulation condition such as the reflecting properties in order to predict the optical performances of collimating films accurately. Quantitative correlation between the optical characteristics of collimating films and the reflecting properties of reflection films can be used to improve simulation technique for the development and the optimization of collimating films for LCD backlight applications.

전자포탈영상을 이용한 다엽시준기의 정도관리 (Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging)

  • 진호상;;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.151-160
    • /
    • 2003
  • 삼차원 입체조형방사선치료나 세기조절방사선치료와 같은 다엽시준기(Multileaf Collmator, MLC)를 이용하는 보다 복잡한 방사선 치료 기술은 다엽시준기의 위치 및 운동의 검증의 중요성을 증가시키고 있다. 이러한 다엽시준기의 검증은 신뢰성과 그동안 축척된 경험적 검증능력으로 인하여 주로 필름을 가지고 수행되어왔다. 그러나 전자포탈영상장치(Electornic Portal Imaging Device, EPID)의 사용의 편이성과 디지털 영상 제공 능력은 낮은 임상편이성, 효율성, 비용대 수익률에도 불구하고 정기적인 정도확립(Quality Assurance, QA)에 현실적인 필름의 대체재로 관심을 모아왔다. 본 연구에서는 EPI를 활용한 다엽시준기의 정기적인, 특히 일간 정도확립법을 개발하였다. 정기적 정도확립을 위한 전자포탈영상(Electronic Portal Imaing, EPI)의 적용가능성에 대한 검증은 방사선 조사시 동시에 획득된 필름과 다엽시준기의 제어장치에 입력한 다엽시준기의 처방과의 비교를 통해 수행되었다. 특별히 설계된 두가지 형태의 시험형(test pattern)이 영상 획득 및 비교에 적용되었다. 정성적인 온라인 육안 검증과 함께 윤곽 검출 알고리듬을 이용한 정량적인 오프라인 분석이 검증 절차에 이용되었다. 결론적으로, 본 연구에서 개발된 EPI를 이용한 다엽시준기의 일간 정도확립법은 필름의 정확도를 가지고 편리하게 수행될 수 있었다.

  • PDF

Current Status of the Synchrotron Small-Angle X-ray Scattering Station BL4C1 at the Pohang Accelerator Laboratory

  • Jorg Bolze;Kim, Jehan;Huang, Jung-Yun;Seungyu Rah;Youn, Hwa-Shik;Lee, Byeongdu;Shin, Tae-Joo;Moonhor Ree
    • Macromolecular Research
    • /
    • 제10권1호
    • /
    • pp.2-12
    • /
    • 2002
  • The small-angle X-ray scattering (SAXS) beamline BL4C1 at the 2.5 GeV storage ring of the Pohang Accelerator Laboratory (PAL) has been in its first you of operation since August 2000. During this first stage it could meet the basic requirements of the rapidly growing domestic SAXS user community, which has been carrying out measurements mainly on various polymer systems. The X-ray source is a bending magnet which produces white radiation with a critical energy of 5.5 keV. A synthetic double multilayer monochromator selects quasi-monochromatic radiation with a bandwidth of ca. 1.5%. This relatively low degree of monochromatization is sufficient for most SAXS measurements and allows a considerably higher flux at the sample as compared to monochromators using single crystals. Higher harmonics from the monochromator are rejected by reflection from a flat mirror, and a slit system is installed for collimation. A charge-coupled device (CCD) system, two one-dimensional photodiode arrays (PDA) and imaging plates (IP) are available its detectors. The overall performance of the beamline optics and of the detector systems has been checked using various standard samples. While the CCD and PDA detectors are well-suited for diffraction measurements, they give unsatisfactory data from weakly scattering samples, due to their high intrinsic noise. By using the IP system smooth scattering curves could be obtained in a wide dynamic range. In the second stage, stating from August 2001, the beamline will be upgraded with additional slits, focusing optics and gas-filled proportional detectors.

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • 한국의학물리학회지:의학물리
    • /
    • 제11권2호
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

선형가속기를 이용한 방사선 수술의 선량분포의 실험적 확인 (Verification of Dose Distribution for Stereotactic Radiosurgery with a Linear Accelerator)

  • 박경란;김계준;추성실;이종영;조철우;이창걸;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.421-430
    • /
    • 1993
  • The calculation of dose distribution in multiple arc stereotactic radiotherapy is a three-dimensional problem and, therefore, the three-dimensional dose calculation algorithm is important and the algorithm's accuracy and reliability should be confirmed experimentally. The aim of this study is to verify the dose distribution of stereotactic radiosurgery experimentally and to investigate the effect of the beam quality, the number of arcs of radiation, and the tertiary collimation on the resulting dose distribution. Film dosimetry with phantom measurements was done to get the three-dimensional orthogonal isodose distribution. All experiments were carried out with a 6 MV X-ray, except for the study of the effects of beam energy on dose distribution, which was done for X-ray energies of 6 and 15 MV. The irradiation technique was from 4 to 11 arcs at intervals of from 15 to 45 degrees between each arc with various field sizes with additional circular collimator. The dose distributions of square field with linear accelerator collimator compared with the dose distributions obtained using circular field with tertiary collimator. The parameters used for comparing the results were the shape of the isodose curve, dose fall-offs fom $90\%$ to $50\%$ and from $90\%\;to\;20\%$ isodose line for the steepest and shallowest profile, and $A=\frac{90\%\;isodose\;area}{50\%\;isodose\;area-90\%\;isodose\;area}$(modified from Chierego). This ratio may be considered as being proportional to the sparing of normal tissue around the target volume. The effect of beam energy in 6 and 15 MV X-ray indicated that the shapes of isodose curves were the same. The value of ratio A and the steepest and shallowest dose fall-offs for 6 MV X-ray was minimally better than that for 15 MV X-ray. These data illustrated that an increase in the dimensions of the field from 10 to 28 mm in diameter did not significantly change the isodose distribution. There was no significant difference in dose gradient and the shape of isodose curve regardless of the number of arcs for field sizes of 10, 21, and 32 mm in diameter. The shape of isodose curves was more circular in circular field and square in square field. And the dose gradient for the circular field was slightly better than that for the square field.

  • PDF

보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究) (Survery on Business of the Departments of Radiology in Health Centers)

  • 최종학;전만진;허준;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF