• Title/Summary/Keyword: collection size

Search Result 677, Processing Time 0.028 seconds

Problems in Quantification of Adequacy of Academic Library Collections -Critical Analysis of Standards for Academic Libraries in the U.S.- (종합대학 도서관장서의 적정량기준 설정에 관한 고찰 -미국의 종합대학도서관기준을 중심으로-)

  • Chung Young Sun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.8
    • /
    • pp.183-207
    • /
    • 1981
  • Library standards have been the source of considerable controversy, whereas many problems are involved in developing stardard for university library collections. For evaluation purposes, standards should be precise, quantifiable and measurable. In the United States, however, standards for academic libraries are limited to qualitative statements and principles. Quantitative standards, when given, are ususally related to the number of population in the institution being served, or the prescribed quantitative objectives are often arbitrarily formulated by value judgements. The study in this paper attempts to explain the problems involved in developing quantitative standard for academic library collections. Two problems facing in the formulation of the optimal size of collection are identified. One is the theoretically faulty concept of adequacy of collection to meet the situations of diversity of university libraies, and the other is the difficulties in quantification and measurement, along with the lack of concept of adequacy of collection. However, quantification of adequate size of collection is proved to be useful on the pratical level, even though not valid theoretically. ACRL, Clapp/Jordan and Voigt developed formulas or models for setting the optimal size of a library collection for any particular university library. The main purpose of this study is the analysis of the above formulas. ACRL standard was drawn from obervation and analysis of statistcs in leading library collections. In academic field, this judgement appears to have been based on the assumption that a high-grade institution would be apt to have a good library collection. This study criticizes ACRL standard for its failure to include some determinants of measurements, and points out the limitations of the standard. In contrast. Clapp/Jordan developed a formula rather scientifically based upon bibliographical sources. This is similarly empirical but has the advantage of bringing into play the elements which make universities diverse in nature. Both ACRL and Clapp/Jordan formulas share two major defects. (1) the specific subject needs of the collection are not indiacted directly, and (2) percentage rate of growth is an indicator in measuring the potential utility of a collection. Thus both formulas failed to provide a basis for meaningful evaluation. Voigt further developed a model for determining acquisition rates for currently published materials based on bibliographic technique. Voigt model encourages experimentation with different programs and different allocations of input resources, designed to meet the needs of the library's particular population. Standard for university library collections can be formulated in terms of input(traditional indicator), or additionally, in terms of output(cost-effectiveness). Cost effectiveness is expressed as user satisfaction, ability to provide wanted materials within a reasonable time period. Thus simple quantitative method does not cover all the situations of diversity of university library collections, nor measures the effectiveness of collections. Valid standard could not be established without further research.

  • PDF

Numerical analysis of particle behavior around a bipolar charged electret fiber (정전 섬유필터 주위의 입자포집 및 거동에 관한 수치해석적 연구)

  • An, Gang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1509-1517
    • /
    • 1997
  • Charged and uncharged particle motions and collection characteristics around a bipolar charged rectangular shape electret fiber are studied numerically. Particle inertia, fluid drag, Coulomb force and polarization force are considered to predict the particle motion around the electret fiber. The effects of particle sizes, flow velocities, number of charges and polarities are also systematically investigated. For small size particles, the single fiber collection efficiency is greatly dependent on the charge polarity and the number of charges on a particle. However, particles larger than 5.mu.m do not show charging effect on collection efficiencies in the flow velocity ranges from 1.5 cm/s to 150 cm/s when the maximum charges are within +5 to -10. The results show that a strong electric field gradient at the corner of the bipolar charged fiber plays a very important role on collecting particles regardless of its charge polarity because of the polarization force. It also shows that the most penetrating particle size for a single electret fiber decreases as the flow velocity increases and the number of charges of a particle decreases.

Classification of Nanoparticles by Inertial/Diffusion Filter (관성/확산필터를 이용한 나노입자의 분류기술 연구)

  • Kim, Yonggu;Lee, Sangyul;Kim, Hannah;Noh, Hakjae;Bong, Choonkeun;Kim, Daesung
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.29-36
    • /
    • 2015
  • The purpose of this research is to find out the collection property of nanoparticle in diffusion filter to know particle size dispersion of nanomaterial using inertial force and principle of Brownian diffusion motion. We used inertial filters which are two different type and diffusion filters made by various kinds of Wiremesh and the different pieces of filter to compare with particle size distribution using NaCl particles. Finally, We made a conclusion as follows : (1) the bigger available charging volume is and the larger specific surface area of inertial filter is, the better collection efficiency is. (2) The higher wire-mesh number of filter is, the more collection efficiency of small particle is increasing because the wire of the higher Wiremesh number filter is thinner and denser. (3) The more pieces of wire-mesh filter, the more collection efficiency is increasing because it makes the residence time longer.

Numerical Analysis on Wire-Plate Electrostatic Precipitator Performance for Bioaerosol Capture: Effect of Ionic Wind (와이어-평판 형태의 전기집진기식 바이오-에어로졸 포집기 성능 수치해석: 이온풍의 영향)

  • Hyun Sik Choi;Gihyeon Yu;Jungho Hwang
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.89-100
    • /
    • 2023
  • In our previous study, a wire-plate type electrostatic precipitator (ESP) was developed to collect bioaerosols of 100 nm size. In the study, various flow rates (40 ~ 100 L/min) and applied voltages (3 ~ 10 kV) were tested for experiment. In this study, numerical analysis was performed for the ESP of the previous study with the same flow rates and applied voltages, but with varying the size of bioaerosols to 0.04 ~ 2.5 ㎛. Overall, the numerical analysis results well predicted the experimental data. Bioaerosols of 0.1 ~ 0.5 ㎛ showed the minimum collection efficiency for all conditions because of low charge number. The effect of the ionic wind generated by the corona discharge was calculated. However, the ionic wind did not affect much the collection efficiency. The aerosol collection in the ESP of this study was due to the electrostatic force generated by particle charge in the electric field. This numerical study on the ESP can be used for the design and optimization of higher flow rate (> 100 L/min) ESP.

Effect of Secondary Flows on the Particle Collection Efficiency in Single Stage Electrostatic Precipitator (1단 전기 집진기에서 2차 유동이 집진 효율에 미치는 영향)

  • Lee, Jae-Bok;Bae, Gwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.251-259
    • /
    • 2000
  • The ionic wind formed in a nonuniform electric field has been recognized to have a significant effect on particle collection in an electrostatic precipitator(ESP). Under normal operating conditions the effect of ionic wind is not pronounced. However, as the flow velocity becomes smaller, the ionic wind becomes pronounced and induces secondary flow, which has a significant influence on the flow field and the particle collecting efficiency. In this paper, experiments for investigating the effect of secondary flow on collection efficiencies were carried out by changing the flow velocities in 0.2-0.7m/s and the applied voltages in 9-11kV/cm. The particle size distributions and concentrations are measured by DMA and CNC. To analyze the experimental results, numerical analysis of electric filed in ESP was carried out. It shows that particle collection is influenced by two independent dimensionless numbers, $Re_{ehd}\;and\;Re_{flow}$ not by $N_{ehd}$ alone. When $Re_{flow}$, decreases for constant $Re_{ehd}$, the secondary flow prohibits the particle collection. But when $Re_{ehd}$ increases for constant $Re_{flow}$, it enhances the particle collection by driving the particles into the collection region.

Numerical Simulation of Impactor Collection Efficiency according to Altitude (대기 고도에 따른 입자 포집용 관성 임팩터의 설계 및 포집효율 예측)

  • Kim, Gyuho;Yook, Se-Jin;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, the collection efficiency of inertial impactors was numerically simulated by employing the statistical Lagrangian particle tracking(SLPT) model. The SLPT model was proven to be correct in predicting the impactor collection efficiency, when the numerically obtained collection efficiencies were compared with the experimental data of Marple et al.(1987) at normal pressure level and the experimental data of $Marjam{\ddot{a}}ki$ et al.(2000) at low pressure level. Based on the validation results, balloon-borne impactors with the cut-off sizes of $1{\mu}m$, $2.5{\mu}m$, and $10{\mu}m$ were designed. Then, the sampling flowrates of the inertial impactors, required to keep the cut-off sizes constant at different pressures and temperatures, were estimated according to the altitude.

Performance of Automotive Cabin Air Filter for Passenger Cars (승용차용 Cabin Air Filter의 성능)

  • 박영옥;구철오;임정환;김홍룡;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.279-287
    • /
    • 1996
  • Pressure drop and fractional collection efficiency of automotive cabin air filters were examined to obtain the basic data for the development of high performance domestic cabin air filters. Pressure drop of MA-V100 was higher than that of VF-V100, and it increased with the air flow rate. VF-V100 had longer time to rise the critical pressure drop than that MA-V100 had. Total collection efficiency of MA-V100 for initial and dust loaded conditions was higher than that of VF-V100. Also, fractional collection efficiency of MA-V100 for the fine particles was higher than that of VF-V100. Particla size distribution for the minimum collection efficiency ranged from 0.02 $\mu$m to 0.04 $\mu$m for MA-V100 and it ranged from 0.02 $\mu$m to 0.15 $\mu$m for VF-V100.

  • PDF

An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber (덕트형 세정집진기의 입자포집 특성실험)

  • Yoo, Kyung-Hoon;Yeo, Kuk-Hyun;Son, Seung-Woo;Hwang, Kwang-Ho;Jung, Jin-Won;Kim, Yoon-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

An Experiment on Particle Collection and Gas Removal in a 2-Stage Electrostatic Wet Scrubber (2단 정전식 세정집진기의 집진 및 가스제거 특성)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Son, Seung-Woo;Kim, Yoon-Shin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.745-752
    • /
    • 2006
  • DOS and NaCl aerosol particles were used to determine collection efficiencies of a 2-stage electrostatic wet scrubber with respect to particle size. The DOS and NaCl aerosols have geometric mean diameters of 0.1-3.0 urn, geometric standard deviations of $1.1{\sim}1.8$ and total number concentrations of $450{\sim}2,400\;particles/cm^3$. The tested operating variables for the electrostatic wet scrubber included air velocity and water injection rate. It was shown from the experimental results that particle collection efficiencies increased in the submicron particle size range when different polarities were applied on the water nozzle and corona wire, respectively. This increase in the collection efficiency is attributed to strong electrostatic attraction between the negative water droplets and positive submicron particles. The collection efficiencies also increased when water injection rate was increased or air velocity was decreased. Meanwhile, the pressure drop across the wet scrubber decreased by 90% compared with the existing mechanical wet scrubber. Finally, ammonia gas was used to determine gas removal efficiencies. It was observed that the gas removal efficiencies increased when the air velocity was decreased or the water injection rate was increased.

Development of wet-sampler for collection and fractionation of micron-sized particles (마이크로 입자의 습식 수집 및 분획 장치 개발)

  • Eum, Chul-Hun;Kang, Dong-Young;Lee, Seung-Ho
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.429-434
    • /
    • 2011
  • In this study, a wet-sampler was developed for collection in water and simultaneous fractionation of micron-sized particles (e.g., pigment, airborne, etc.). In this new device, three cylinders (partially filled with water) through which air was forced to pass for sample collection are connected in a series. Particles of different sizes are collected in different cylinders, allowing simultaneous fractionation. An uniqueness of this new device is that it does not use any membrane filter. Microparticles are collected directly in cylinders filled partially with water. Also the particles are simultaneously fractionated within this device while they are being collected. The new device was employed for collection of airborne particles. The collected airborne particles were fractionated by using sedimentation field-flow fractionation, SdFFF), and observed with an optical microscopy (OM) for size and shape analysis. Also AAS and ICP-AES were used for composition analysis of the airborne particles. It is expected that the new device is applicable to collection and analysis of size distribution of various types of microparticles.