• Title/Summary/Keyword: collection size

Search Result 665, Processing Time 0.027 seconds

Improvement of an Identified Slot Sacn-Based Active RFID Tag Collection Algorithm (인식 슬롯 스캔 기반 능동형 RFID 태그 수집 알고리즘 개선)

  • Yoon, Won-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.3
    • /
    • pp.199-206
    • /
    • 2013
  • This paper proposes a modified tag collection algorithm that improves the drawback of the identified slot scan-based tag collection algorithm presented in a previous paper to improve the tag collection performance in active RFID systems. The previous identified slot scan-based tag collection algorithm is optimized in situations where all the tags store the fixed size of data, so it could not result in a good performance improvement with tags having the variable size of data. The improved tag collection algorithm proposed in this paper first collects the slot size information required for the data transmission from each tag via the identified slot scan phase, and then performs the tag collection phase using the information, which resolves the problem of the previous identified slot scan-based tag collection algorithm. The simulation results for performance evaluation showed that the proposed tag collection algorithm resulted in the almost same tag collection performance as the previous algorithm when all the tags have the same size of data and led a large improvement of the tag collection performance in ISO/IEC 18000-7 unlike the previous algorithm when each tag has a random size of data.

The Technology of Mist Removal in Flue Gas by the Plasma of Impulse Streamer Corona (저온플라즈마에 의한 배연 가스내의 미스트 처리기술)

  • 하상안;김일배;강신묵
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.69-76
    • /
    • 1999
  • This research was carried but to investigate the characteristics of mist removal with the change of operating conditions in the plasma reactor of impulse streamer corona based on the distribution of particle size measured by laser diffraction spectrometers. The operating conditions in this experiment were power of impulse streamer corona, gas velocity, collection time, and SOx/NOx concentration. The collection efficiency T(d) was estimated by distribution of particle size in the collection zone through the advanced model.

  • PDF

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

A Basic Study on Developing an Electrocharged Scrubber (전기하전식 세정집진장치 개발에 관한 기초 연구)

  • 김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF

Characteristics of Seed and Plant Growth in Local Collections of Agastache rugosa

  • Ok, Hyun-Chung;Chae, Young-Am
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.4
    • /
    • pp.269-272
    • /
    • 1998
  • Characteristics of seed and plant growth of the nine local collections of the medicinal plant, Agastache rugosa were evaluated. Seed size of the collection from Garyungsan was larger than the others. Seeds of Damyang collection were the smallest in size. Seeds of the collections were mostly oval shaped. There were no differences between brown and black seed coat color groups in seed width, ratio of seed length to seed width and 1,000 seed weight. Stem lengths of Garyungsan and Bongpyung collections were 99.9 and 95.6 cm, respectively, and were longer than Damyang and Jindo collections. Garyungsan collection had long leaf shape. Leaf size was the smallest for Damyang collection, but was the largest for Bongpyung collection. Inflorescence length of Mokpo collection (15.6 cm) was longer than the average over all collections (12.3 cm). Damyang collection was the shortest (10.1 cm) in inflorescence. Top dry weight of each collection from Soonchun, Bongpyung, Mokpo, Jindo, and Gurye was greater than the average over all collections (20.38 g/plant). Jinju and Damyang collections had less top dry matter than others. There was no difference in the growth traits examined between brown and black seed coat groups. The brown seed group was greater in leaf weight than the black seed group. However, these two groups were not different in stem and inflorescence weight. Collections of A. rugosa from Bongpyung, Soonchun, and Mokpo were promising for commercial cultivation because of their great top dry weight, especially in leaf and inflorescence.

  • PDF

Characteristics of Cylindrical Electrostatic Precipitator with Centrifugal Effect (원심력 효과를 고려한 실린더형 전기집진기의 특성)

  • Lee, Joon;Jo, Yong-Soo;Yoa, Seok-Jun
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.351-358
    • /
    • 2001
  • The main purpose of this study was to investigate the characteristics of cylindrical electrostatic precipitator with centrifugal effect in viewpoints of pressure drip and collection efficiency, experimentally. The experiment was carried out for the analysis of current-voltage, pressure drop and collection efficiency with various experimental parameters such as the applied voltage, inlet velocity, inlet size and inlet type(upper and bottom), etc. In the results, the pressure drops were estimated as 27~54, $34~63mmH_2O$ for inlet size $15mm{\tiems}30mm$ and $30mm{\tiems}60mm$, respectively. The collection effeciencies were shown over 90% with the small inlet size($15mm{\tiems}30mm$) for the applied voltage 40kV, inlet velocity(15~21m/s), and 51~89% with the large inlet size ($30mm{\tiems}60mm$). Moreover, in the applied voltage 0kV and inlet size $15mm{\tiems}30mm$, the collection efficiency induced by centrifugal force was represented as about 35% with inlet velocity 15 - 21m/s.

  • PDF

Study on the Simulation for the Removal of Different Sized Particles in Suspension by Deep-Bed Filtration

  • Choo, Chang-Upp
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.18-22
    • /
    • 2005
  • A model was proposed for investigating the particle removal from suspension with particles of different sizes by deep-bed filtration, and the collection efficiency was predicted by computer simulation. Deposited particles on the pore surface may act as additional collector and reduce the pore size, which contribute to the improved collection efficiency with increase of deposition. Computer experiments for suspension of particles of three sizes and its equivalent size of mono particles were carried out and compared. The collection efficiency of suspension with poly-dispersed particles shows higher efficiency than that of suspension with mono-dispersed particles. Also the collection efficiency of smell particle of mixture is higher that that of same uniform size particles.

Electric Collection Filter for Ultrafine Dust Removal (초미세먼지 제거를 위한 전기집진 필터에 관한 연구)

  • Kim, Yong Sun;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.40-45
    • /
    • 2022
  • In recent years, indoor air pollution has become a crucial environmental problem. Hence, the purification of indoor air is an important issue. Typical physical filters show relatively high dust collection efficiency at a dust particle size of more than 5.0 ㎛ but extremely low efficiency at an ultrafine size of less than 2.5 ㎛. In this study, an electric field filter was proposed to capture ultrafine dust with a size of less than 5.0 ㎛. Simulation results showed that the electric field filter effectively removed ultrafine dust. In addition, sufficient dust collection efficiency was obtained even with a simple plate-shaped filter without bending the Chevron filter.

A Combination of the Frozen Raindrop Collection Method and a High-performance Capillary Electrophoresis Technique for the Size-resolved Raindrops Study

  • Ma, Chang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.27-34
    • /
    • 2006
  • Although the importance of size-resolved raindrops study has been known, it has not been popularized up to the present. In the present study, an attempt was made to generalize the size-resolved raindrops study by a combination of the frozen raindrop collection method and a commercially available high-performance capillary electrophoresis (HPCE). Samplings were carried out at Kyoto, Japan in October 2002. The inorganic ions (chloride, nitrate, sulphate, calcium, ammonium, sodium, magnesium, potassium) in size classified raindrop samples were successfully analyzed by HPCE with good repeatability. To assure the accuracy and precision of HPCE data, t-test was conducted with paired analytical data, which were experimentally constructed by analyzing standard solutions with HPCE and IC, respectively. T-test showed that there is no notable difference between the concentrations determined by the two analytical methods. Every ionic concentration in both cation and anion was found to be strong raindrop size dependence. Though there was slight increase of sodium and sulphate concentrations between 0.85 mm and 1.15 mm raindrop radius, it showed a strong decrease for every ionic component with increasing droplet radius. The combination of the frozen raindrop collection method and a commercially available HPCE can meet the need of size-resolved raindrops study.

An Experimental Study on Particle Collection Efficiency of the Slit Impactor (슬릿 임팩터의 입자 포집 효율에 관한 연구)

  • 황창덕;허재영;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.689-696
    • /
    • 1989
  • In this experimental study, relative particle size distribution was measureed at the inlet and outlet of the slit impactor using the particle sizer. The imployed measuring method of the size distribution was different from the conventional method. This measurement system has the advantage of obtaining the particle collection efficiency for various particle size easily and at once compared with other methods. The effects of jet to plate distance and Reynolds number on the characteristic impactor efficiency curves have been studied. In the results of this experiment, the increment of collection efficiency was observed as Reynolds number increases in the case of S/W = 1/2 but was very slight. The influence of S/W is more remarkable than that of Reynolds number on the particle collection efficiency.