• Title/Summary/Keyword: collapse design

Search Result 702, Processing Time 0.031 seconds

Study on Obstacle Deflector of a Railway Vehicle Using Tension-type Energy Absorbers (인장형 에너지흡수부재를 이용한 철도차량용 장애물제거기 연구)

  • Kim, Hongeik;Kim, Jinsung;Kwon, Taesoo;Jung, Hyunseung
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.173-181
    • /
    • 2017
  • The obstacle deflector sweeps obstacles off the track or absorbs crash energy with an energy absorber to prevent derailment of a train and to minimize damage and casualties after an accident. In this study, an obstacle deflector and its operational mechanism were designed with a tension-type energy absorber and a 4-bar linkage system. Also, a test method was suggested and verified with FEA (Finite Element Analysis) and UTM (Universal Test Machine) for testing of the static load and energy absorbing ability according to EN 15227 regulations. Through this study, an obstacle deflector that meets the EN 15227 standard was designed and a test method was suggested to adjust the collapse load easily and to verify it experimentally according to the design and verification procedure of the obstacle deflector.

A case study of 3D seismic reflection imaging in an area of ground subsidence (지반 침하지역에서의 3차원 탄성파 반사법에 의한 지하구조 영상화 사례)

  • Ko, Kwang-Beom;Lee, Doo-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2000.09a
    • /
    • pp.158-172
    • /
    • 2000
  • In order to visualize mine cavities, 3D seismic reflection data were acquired at the ground subsidence sites near Nampung coal mine area, Neukguri, Dogye, Samchuck. Full range 3D array with complete range of azimuths on the bins was considered in the data acquisition design. Because of poor S/N data, we estimated the stacking velocities by CVS method, and we estimated the shot and receiver statics on the shot and receiver stack data. We could confirm that features of ground collapse that were expected from the subsidence. In order to visualize the cavities, we need to apply more sophisticated processing schemes, such as velocity analysis, residual statics correction.

  • PDF

Study on a Standardized Rockfall-Protection Fence for Various Rockfall Impact Energy using Finite Element Analysis (유한요소해석을 이용한 다양한 낙석 충돌에너지에 대한 표준 낙석방지울타리 형식 제시 연구)

  • Park, Hyungon;Jang, Hyunick;Kim, Bumjoo;Moon, Jiho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.297-302
    • /
    • 2020
  • Korea has many mountainous regions, and slope collapse that can lead to damage in road facilities and loss of lives often occurs. Rockfall-protection facilities are necessary to reduce such damages. Among these facilities, the standard Korean rockfall-protection fence is designed to resist 50 kJ of rockfall impact energy. However, the range of rockfall energy significantly varies depending on the condition of the slope, and it sometimes reaches up to 100 kJ. Thus, providing several types of standardized rockfall-protection fence is necessary to address the different rockfall impact energy for efficient response to rockfalls. This paper presents a study on standardized rockfall-protection fence for various rockfall impact energy using finite-element analysis. According to the results, standardized rockfall-protection fences against rockfall impact energy of 30 and 100 kJ were proposed and have been verified.

Tests on the Serial Implosion of Multiple Cylinders Subjected to External Hydrostatic Pressure (외부 정수압을 받는 복수 원통의 연쇄 내파에 관한 실험연구)

  • Teguh, Muttaqie;Park, Sang-Hyun;Sohn, Jung Min;Cho, Sang-Rai;Nho, In Sik;Lee, Phill-Seung;Cho, Yoon Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.4
    • /
    • pp.213-220
    • /
    • 2020
  • In the present paper, implosion responses of two adjacent cylindrical tubes under external hydrostatic pressure were experimentally investigated. The cylinder models were fabricated of aluminium alloy 6061-T6 commercial tubes. In the experiment, a pair of two-cylinders were placed inside of a support frame in a medium-size pressure chamber, whose design pressure was 6.0MPa. The distance between the two-cylinders was 30 millimeter measured from outer shell at the mid-length. The implosion tests were performed with water and compressed nitrogen gas as the pressurizing media. The ambient static pressure of the chamber and local dynamic pressure near the two-imploded models were measured simultaneously. It was found that the energy released during an implosion from the first, weaker cylinder triggered the instability of the second, stronger cylinders. In other words, the resulting shock wave of the first implosive impact from the weaker cylinder could cause the premature failure of the neighboring stronger cylinders. The non-contact implosion phenomena from the two-cylindrical tube were clearly observed.

Study on the Effective Method of Fire Protection Technology in Railway Tunnel Fire (철도터널 내화성능 기술개발을 위한 내화성능 확보방안에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Yeol;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.86-91
    • /
    • 2010
  • In event of a tunnel fire, all kinds of equipment can be destroyed in high temperature that can exceed $1300^{\circ}C$, fatal structural demage can be caused by spalling of concrete structural elements. To make matters worse, there is a high possibility of the secondary damage which can lead to the collapse of the shear resisting structure. Accordingly, it is time that we developed the technology to counter fires in connection with the fire-resistant design of a tunnel structure. To secure the reliability of the fire-resistance performance of a tunnel structure, it is necessary to assess the fire's behavior on every structural element exposed to the fire as well as to calculate the tunnel fire intensity and the quantity of heat released. In this study, we drew out the fire damage range of each structural element of a tunnel and the minimum thickness of concrete cover for each fire-resistant material through some actual experiments of fire behavior on the structural elements of a tunnel.

Estimating Geotechnical System Response Probability of Internal Erosion Risk in Fill Dam using Event Tree Analysis (사건수 분석 기법을 이용한 필댐의 내부 침식 위험도에 대한 지반공학적 시스템 응답 확률 산정)

  • Noh, Kyung-Lyun;Lim, Jeong-Yeul;Mok, Young-Jin;Jung, Young-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1815-1829
    • /
    • 2014
  • Recently frequent collapse of old fill dams has taken place, which increases social awareness in the safety of the infrastructure. Fill dams in Korea has been incautiously regarded as safe once the fill dam is considered to have a full capacity to retain a conservative design flood determined by government authorities. However, developed foreign countries has been managing their fill dams by introducing systematic risk assessment techniques over a long period of time. In this study, the system response probabilities of the deteriorated old fill dams in Korea were systematically evaluated and analyzed by using the internal erosion toolbox based on the event tree analysis technique. The probability of the existence of flaw and the magnitude of the hydraulic gradient through a potential crack can significantly influence the geotechnical system response probability. The results of this study show that the probability of the existence of flaw and the magnitude of the hydraulic gradient through a potential crack can significantly influence the geotechnical system response probability and the risk of the deteriorated fill dam can be quantitatively assessed.

Effect of tension stiffening on the behaviour of square RC column under torsion

  • Mondal, T. Ghosh;Prakash, S. Suriya
    • Structural Engineering and Mechanics
    • /
    • v.54 no.3
    • /
    • pp.501-520
    • /
    • 2015
  • Presence of torsional loadings can significantly affect the flow of internal forces and deformation capacity of reinforced concrete (RC) columns. It increases the possibility of brittle shear failure leading to catastrophic collapse of structural members. This necessitates accurate prediction of the torsional behaviour of RC members for their safe design. However, a review of previously published studies indicates that the torsional behaviour of RC members has not been studied in as much depth as the behaviour under flexure and shear in spite of its frequent occurrence in bridge columns. Very few analytical models are available to predict the response of RC members under torsional loads. Softened truss model (STM) developed in the University of Houston is one of them, which is widely used for this purpose. The present study shows that STM prediction is not sufficiently accurate particularly in the post cracking region when compared to test results. An improved analytical model for RC square columns subjected to torsion with and without axial compression is developed. Since concrete is weak in tension, its contribution to torsional capacity of RC members was neglected in the original STM. The present investigation revealed that, disregard to tensile strength of concrete is the main reason behind the discrepancies in the STM predictions. The existing STM is extended in this paper to include the effect of tension stiffening for better prediction of behaviour of square RC columns under torsion. Three different tension stiffening models comprising a linear, a quadratic and an exponential relationship have been considered in this study. The predictions of these models are validated through comparison with test data on local and global behaviour. It was observed that tension stiffening has significant influence on torsional behaviour of square RC members. The exponential and parabolic tension stiffening models were found to yield the most accurate predictions.

Ultimate strength performance of Northern sea going non-ice class commercial ships

  • Park, Dae Kyeom;Paik, Jeom Kee;Kim, Bong Ju;Seo, Jung Kwan;Li, Chen Guang;Kim, Do Kyun
    • Structural Engineering and Mechanics
    • /
    • v.52 no.3
    • /
    • pp.613-632
    • /
    • 2014
  • In the early design stage of ships, the two most important structural analyses are performed to identify the structural capacity and safety. The first step is called global strength analysis (longitudinal strength analysis or hull girder strength analysis) and the second step is local buckling analysis (stiffened panel strength analysis). This paper deals with the ultimate strength performance of Arctic Sea Route-going commercial ships considering the effect of low temperature. In this study, two types of structural analyses are performed in Arctic sea conditions. Three types of ship namely oil tanker, bulk carrier and container ship with four different sizes (in total 12 vessels) are tested in four low temperatures (-20, -40, -60 and $-800^{\circ}C$), which are based on the Arctic environment and room temperature ($20^{\circ}C$). The ultimate strength performance is analysed with ALPS/HULL progressive hull collapse analysis code for ship hulls, then ALPS/ULSAP supersize finite element method for stiffened panels. The obtained results are summarised in terms of temperature, vessel type, vessel size, loading type and other effects. The important insights and outcomes are documented.

Assessment of groundwater inflow rate into a tunnel considering groundwater level drawdown and permeability reduction with depth (터널굴착 중 지하수위 강하 및 깊이별 투수계수 변화를 적용한 지하수 유입량 변화 분석)

  • Moon, Joon-Shik;Zheng, An-Qi;Jang, Seoyong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.109-120
    • /
    • 2017
  • Groundwater seepage into a tunnel is one of the main causes triggering tunnel collapse and the consequent ground subsidence. Thus, it is important to estimate adequately the groundwater inflow rate and porewater pressure change during tunneling with time elapse. In current practice, Goodman's analytical solution (or image tunnel method) assuming homogeneous ground condition around a tunnel is commonly used for estimating groundwater inflow rate. However, the generally-used analytical solution for estimating groundwater inflow rate does not consider groundwater level drawdown and permeability change with depth, and the inflow rate can be overestimated in design phase. In this study, parametric study was performed in order to investigate the effect of groundwater level drawdown and permeability reduction with depth, and transient flow analysis was carried out for studying the inflow rate change as well as groundwater level and porewater pressure change around a tunnel with time elapse.

Seismic Fragility Analysis of Base Isolated NPP Piping Systems (지진격리된 원전배관의 지진취약도 분석)

  • Jeon, Bub Gyu;Choi, Hyoung Suk;Hahm, Dae Gi;Kim, Nam Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Base isolation is considered as a seismic protective system in the design of next generation Nuclear Power Plants (NPPs). If seismic isolation devices are installed in nuclear power plants then the safety under a seismic load of the power plant may be improved. However, with respect to some equipment, seismic risk may increase because displacement may become greater than before the installation of a seismic isolation device. Therefore, it is estimated to be necessary to select equipment in which the seismic risk increases due to an increase in the displacement by the installation of a seismic isolation device, and to perform research on the seismic performance of each piece of equipment. In this study, modified NRC-BNL benchmark models were used for seismic analysis. The numerical models include representations of isolation devices. In order to validate the numerical piping system model and to define the failure mode, a quasi-static loading test was conducted on the piping components before the analysis procedures. The fragility analysis was performed by using the results of the inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using the shell finite element model of a piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. In addition, the collapse load point was used for the failure mode for the fragility analysis.