• Title/Summary/Keyword: cold environment

Search Result 925, Processing Time 0.04 seconds

A study of the incubator model for growing mushrooms

  • Zheyang, H.;Tengis, Ts.;Batminkh, A.
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2020
  • This article describes the automated incubator designs for white mushrooms growing. Mongolia has a very long and cold winter, so the process of growing mushrooms is short. Therefore, we aim to design an automated incubator system that has created a favorable artificial environment for mushroom growing by examining the necessary conditions for mushroom growing. This system was designed to be able to hold for some time the required levels of soil moisture, air humidity, soil temperature, air temperature, and CO2 levels. This article presents the results of a system-based experiment that allows you to grow mushrooms for 30 days without human interference.

Investigations on High Temperature Filtration System for Particle Removal using Ceramic Candle Filter in the Pilot Scale Vitrification Plant (유리화 공정에서의 세라믹 캔들 필터를 이용한 분진 제거목적의 고온 여과 시스템에 관한 연구)

  • 류보현;박승철;황태원;하종현
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.391-392
    • /
    • 2003
  • 한전 원자력 환경기술원에서는 중ㆍ저준위 방사성폐기물 유리화 기술의 상용화 가능성을 입증하기 위한 유리화 실증설비를 건설하여 시험 중에 있으며 이 유리화 기술은 유도 가열식 저온로(Cold Crucible Melter, CCM)에 폐기물을 투입하는 기술로서 폐기물의 부피 축소 효과와 더불어 최종 고화물로 생성되는 폐기물의 침출율이 매우 낮은 장점을 지닌다. 이와 같은 유리화 공정은 기존의 소각처리에서와 같이 폐기물의 열적 산화과정에 의해 유해오염가스와 입자성 물질이 발생된다. 따라서 이를 처리하기 위해배기체 처리공정(Off Gas Treatment System, OGTS)을 설치하여 환경 배출기준(SO$_2$300ppm, NO$_2$ 200ppm, CO 600ppm, HCI 50ppm, 분진 100mg/Nm$^3$ 등)을 만족하도록 하였고 특히 입자성 물질은 후단 OGTS나 배관내 침적으로 인한 방사성 오염을 막기 위해 CCM 후단에서 효율적으로 제거되어야만 한다. (중략)

  • PDF

The study on characteristic of efflorescence phenomenon and reduction plan through research (사례 조사를 통한 백화현상의 특징 및 저감 방안 연구)

  • 박영민;이희두;이해진;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.1-6
    • /
    • 2002
  • The study offer a suggestion that from result in being a case to efflorescence for decrease a plan: $\circled1$ A efflorescence of concreat a structure will be the prograss plan; In the materials, depress use to the water-sand in the construction, admonish unification of front and rear in the environment, consideration requisite concreat don't the occurrence efflorescence. $\circled2$ Ma sonry building efflorescence establish a ventilation opening and a waterway to ma sonry the times avoid the winter or the rainy season. Ma sonry building efflorescence will be make good among a brick to a brick interval closely mortar. $\circled3$ Tile building, tile of plasticity temperature is appropriate, reduce the deviation, parapet part of efflorescence will be make good closely mortar. A construction material part a meterial developing need Perfection of construction a efflorescence occurrence is the minimum, a plan Part developed so on, composition of a ommection field systematic effort need a efflorescence Prevention a kind of detail.

  • PDF

Strength Development of Mock-up Concrete Structure subjected to Extremely Low Temperature Condition Due to Curing Methods (극저온 조건에서의 양생방법 변화에 따른 실구조체 콘크리트의 강도발현 특성)

  • Jung, Eun-Bong;Jung, Sang-Hyeon;Ahn, Sang-Ku;Ko, Gyeong-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.47-49
    • /
    • 2012
  • Under this study, the characteristics of concrete intensity condition following the curing method under the extremely low temperature environment have been contemplated, and as a result, in the event of insulation + heat cable curing, the intensity and accumulated temperature accomplishment period is required for two times of requiring initial frost damage prevention than the case of heating + heat insulation curing method due to the insufficient calories supplied in general.

  • PDF

Thermal Shroud Design of a Large Space Simulator(${\Phi}8m{\times}L10m$) (대형우주모사장비(${\Phi}8m{\times}L10m$) 열교환 슈라우드 설계)

  • Cho, Hyok-Jin;Moon, Guee-Won;Lee, Sang-Hoon;Seo, Hee-Jun;Winter, Calvin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1236-1240
    • /
    • 2004
  • Thermal vacuum test for satellites should be performed before launch to verify the feasibility of satellites' operation in a harsh space environment which is represented as an extremely cold temperature and vacuum condition. A large space simulator(${\Phi}8m{\times}L10m$) has been demanded to accomplish the thermal vacuum test for the huge satellites designed in compliance with the national space program of Korea. In this paper, the design and calculation of thermal shroud which is the core part of large space simulator were discussed. The characteristics of the large space simulator being constructed at Korea Aerospace Research Institute(KARI) were depicted.

  • PDF

Environmentally Conscious Machining Technology of Aircraft Material(12Cr steel) (항공기소재(고크롬강)의 환경친화적 가공기술)

  • 강명창;김정석;이득우;황윤호;송준호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1051-1054
    • /
    • 2002
  • Environmentally conscious machining and technology have been taking more and more important position in machining process. Since cutting fluid has some impact on environment, many researches are being carried out to minimize the use of cutting fluid. It can be Increased the environmental pollution through not using coolant any more or minimizing it. In this study, the cooling effects of cutting methods using the compressed cold air, dry cutting and cutting fluid will investigate in the blade machining. In order to examine the characteristics of cutting and tool in the environmentally conscious machining, this work investigates experimentally the degree of tool wear, cutting force and characteristics of surface roughness in relation to machining conditions and cooling methods.

  • PDF

24 hours' Exposed Temperature and Thermal Comfort in Summer (여름철 도시의 일상생활에서 경험하는 환경온도와 온냉감 평가)

  • 전정윤;이민정
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.51-56
    • /
    • 2003
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces with temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects were wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Subjects controls their micro climate like this. Most of them(84.6%) get weather information. Fashion(46.2%) and weather(30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Temperature fluctuation which subjects were exposed for 24 hours were from 15.6$^{\circ}C$ to 33.8$^{\circ}C$ and average fluctuation was 9.02$^{\circ}C$. The median value of experienced temperature were 26-26.5$^{\circ}C$ and average temperature was 26.18$^{\circ}C$. They experienced cold shock of 3.96 times in a day.

Freeze and Mechanical Properties of Cement Mortar Using Coolant Wastes (폐부동액을 이용한 콘크리트의 동결 및 역학적 특성)

  • 김상우;김정진;홍상희;전충근;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.555-558
    • /
    • 2000
  • It has been increasingly proving in interest of environment pollution around the world. so, recycling of waste resources are seriously taken into consideration. Great deal of coolant for the car have been wasted for along time. due to the end of life time of them. Therefore, validities of wasted coolant as an agent for concrete are described in this paper. Mechanical properties of concrete using coolant wastes is investigated. As contents of coolant wastes increase, slump and slump flow decrease, while air content show reverse tendency. setting time shows to be accelerated with increase of waste contents. As for the effect of low curing temperature, low curing temperature increase compressive strength with increase of coolant waste. Application of coolant waste to cold weather concrete is considered to achieve favorable effects.

  • PDF

Improvement of Concrete Durability under Deicier and Freez-Thaw Environment (제설제 및 동결융해 환경하에서 콘크리트의 내구성 증진 방안에 관한 연구)

  • Lee, Byung-Duck;Yun, Byung-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.523-526
    • /
    • 2005
  • In order to traffic safety during winter season, snowfall and cold area has been spread the deicing chemicals, and the spraying amount is increasing every year. Use of deicing chemicals has been and will continue to be a major part of highway snow and ice control methods. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, the source of substantial cost penalties due to their corrosive action and acceleration to deterioration concrete structures. Deterioration due to de-icer salt occurs in practice in concrete pavement, dike, barrier and similar structure. This paper reports the results of effect of de-icer salt on durability of concrete structure in winter. To protect concrete structure from damage by de-icer salt in winter, the exposure test was performed using three methods such as increase in design strength upto 32MPa application of granulated blast furnace slag powder, and concrete sealer. Of these, the method of increase in design strength upto 32MPa showed better durability for deterioration by de-icer salt.

  • PDF

TEM Observation Studies on the Chemoautotrophic Symbiotic Bacteria of Invertebrates Inhabiting at Vents and Seeps

  • Kim, Dong-Sung;Ohta, Suguru
    • Ocean and Polar Research
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2000
  • Chemoautotrophic symbiotic bacteria of organisms inhabiting the hydrothermal vent and cold seep communities in the deep-sea were histologically examined using a transmission electron microscopy on symbionts of Calyptogena sp. A from the site east off Miyako (water depth at 1,700m), Calyptogena sp. B from the Calyptogena Site, vestimentiferan tube worm Lamellibrachia sp. A from Sagami Bay Lamellibrachia sp. B from Calyptogena Site of the Iheya Ridge, pogonophoran tube worms from Sagami Bay and Calyptogena Site of the Iheya Ridge, Bathymodiolus spp. from Sagami Bay, the Iheya Ridge and the North Fiji Basin. Based on the morphological microscopic observations, two species of Calyptogena from Miyako and the Iheya Ridge, two species of vestimentiferan tube worms from Sagami Bay and the Iheya Ridge, and pogonophoran tube worms from Sagami Bay and the Iheya Ridge observed to host sulfur-oxidizing symbiotic bacteria. The occurrence of chemosynthetic symbionts in these organisms was expected beforehand based on the ecological observations of their habitats. Other members of these groups from the world oceans, and the recent advances in the symbiosis at vents and seeps were reviewed.

  • PDF