• Title/Summary/Keyword: cold

Search Result 11,075, Processing Time 0.058 seconds

A Survey in the General Population on the Perception of the Common Cold Treatment at the Korean Medical Clinic (한방의료기관에서의 감기 진료에 대한 일반인의 인식 조사)

  • Kim, Do-hyung;Cho, Min-kyoung;Hong, Min-na;Choi, Jun-yong
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.3
    • /
    • pp.336-352
    • /
    • 2017
  • Objective: This study investigated the perception, utilization, and satisfaction (in the general population), of the common cold treatment at the Korean Medical Clinic, to provide basic information for the development of Korean medicine clinical practice guidelines for the common cold. Method: A questionnaire was developed that consisted of questions about the general perception, utilization status, degree of satisfaction, willingness to use, and the improvement of the common cold treatment at the Korean Medical Clinic. An online survey was conducted using this questionnaire. Results: Three-hundred subjects responded to the survey. The results of the analysis were as follows. 1. 73.7% of the subjects recognized the common cold treatment at the Korean Medical Clinic. 2. 72% of the subjects had a positive perception of Korean medicine for common cold treatment. The major reason for the positive perception was the expectation about improving immunity and preventing recurrence. 3. Only 20% of the subjects had visited the Korean Medical Clinic for common cold treatment. The expensive cost was the major reason for not visiting the Korean Medical Clinic for common cold treatment. 4. The ratio of subjects who were willing to visit the Korean Medical Clinic for common cold treatment was 70%. 5. The expansion of health insurance coverage (67.7%), the activation of public relations (54.7%), and the development of a new herb medicine preparation that was easy to take (43.3%) were found to be necessary for improving the Korean medical service for common cold treatment. Conclusion: In spite of high recognition and positive perception, actual utilization of common cold treatment at the Korean Medical Clinic was relatively low. Multifaceted efforts are necessary to enhance the competitiveness of Korean medical service for treatment of the common cold.

Important Items Extracted through the Questionnaire of Cold and Heat Pattern Identification by the Experts' Agreement (전문가의 일치도를 통해 알아본 중요 한증, 열증 지표)

  • Bae, Kwang Ho;Park, Ki Hyun;Lee, Young Seop;Jang, Eun Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • This study intended to find out the most substantial items in cold and heat pattern identification(CHPI) questionnaire based on usual symptoms through CHPI diagnosis and evaluation by experts. 120 participants, faculties of OO university, filled out CHPI questionnaire based on usual symptoms by the way of self-reporting. Then 2 Korean Medicine doctors independently diagnosed them whether they belonged to cold pattern identification(PI) or heat PI, and scored the result of it. Pearson correlation of 2 experts was 0.649 in cold PI and 0.605 in heat PI. Agreement was 75.8%(Kappa value 0.516) in cold PI and 74.2%(Kappa value 0.465) in heat PI. Pearson correlation of 2 experts was 0.649 in cold PI and 0.605 in heat PI. Agreement between two experts was 75.8%(Kappa value 0.516) in cold PI and 74.2%(Kappa value 0.465) in heat PI. Items of high correlation with experts' evaluation followed next: "do not usually like the cold", "usually like the warm", "usually feel cold" in cold PI and "do not usually like the hot", "usually feel hot", "usually feel burning sensation in the body" in heat PI. We could infer from that facts that experts give weight on 'subjective feeling of cold or heat in participants body' and 'preference on sensation of cold and heat'. We also expect this study to be an epidemiological foundation to disclose correlation between usual CHPI and diseases.

Changes in Cell Ca2+ Distribution in Loquat Leaves and Its Effects on Cold Tolerance

  • Zheng, Guohua;Pan, Dongming;Niu, Xianqian;Wu, Hanwen;Zhang, Jinbiao
    • Horticultural Science & Technology
    • /
    • v.32 no.5
    • /
    • pp.607-613
    • /
    • 2014
  • Calcium has been associated with improved cold tolerance in many crops. The aim of this study was to investigate the changes in leaf cell $Ca^{2+}$ distribution and cell organelle ultrastructure of loquat (Eriobotrya japonica Lindl.) plants in response to cold stress at $-3^{\circ}C$, using transmission electron microscopy (TEM). Two loquat accessions, Zaozhong 6 (a commercial cultivar) and oakleaf loquat (a wild relative) were used. Cold tolerance, as measured by leaf browning rate, was higher in oakleaf plants, and calcium treatment improved cold tolerance in both species. Cold stress first induced inward transport of $Ca^{2+}$ from the intracellular space. Then, the imported $Ca^{2+}$ was aggregated around the chloroplast membrane, finally entering the chloroplast. This pattern of $Ca^{2+}$ distribution in leaf cells occurred earlier in Zaozhong 6 than in the wild loquat. With increasing time of cold exposure, the chloroplast membranes of Zaozhong 6 leaves were damaged, blurred and even disappeared, while those of wild oakleaf loquat leaves maintained their structure longer. In Zaozhong 6, cold stress induced a clear cavity between poorly structured granal thylakoids and vesicles appearing inside the chloroplast, while in oakleaf leaves cold stress had little effect on the ultrastructure of chloroplasts (although chloroplast membranes looked blurred). Loquat leaves accumulated free calcium ions around chloroplasts in response to cold stress, with earlier calcium accumulation occurring in the cold-sensitive cultivar Zaozhong 6 than in wild oakleaf loquat. These results demonstrate that these two loquat species have differences in both cold tolerance and calcium accumulation dynamics.

Comparison of Brood Productions in the Cold-Treated Pairing vs. Not Cold-Treated Pairing in a Stenochronous Spider

  • Kim, Kil-Won
    • Journal of Ecology and Environment
    • /
    • v.32 no.3
    • /
    • pp.145-148
    • /
    • 2009
  • To understand whether experience of cold season in reproductive behaviors in the adults of Amaurobius ferox, the paired adults of a female and a male were exposed under 'cold-treated environment' and 'not cold-treated environment', respectively. I investigated effects of the cold treatment on the brood production of A. ferox. In not cold treatment in which male-female pairs were formed in October at a temperature of $20^{\circ}C$ (${\pm}2^{\circ}C$) and continuously kept under not cold-treated environment, only 3 of 50 pairs successfully reproduced (reproduction was defined as the emergence of spiderlings). In cold treatment where individuals were kept in cold conditions for 3 months prior to pair formation, 57 out of 60 couples succeeded in reproducing. Females which did not experience the low temperature displayed strong aggressiveness toward males. This behavioral inhibition might the primary barrier to copulation of A. ferox that decrease following a period of low temperature. The reproductive inhibition might help the females to allocate the maximum amount of energy in a given environment to reaching the adult stage and to delay reproduction in unfavorable wintering conditions.

Flexural-torsional buckling tests of cold-formed steel compression members at elevated temperatures

  • Heva, Yasintha Bandula;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • v.14 no.3
    • /
    • pp.205-227
    • /
    • 2013
  • Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Enhancement of Seed Germination by Aging, Cold-stratification, and Light Quality during Desiccation in Burcucumber (Sicyos Angulatus L.)

  • Kang, Jin-Ho;Jeon, Byong-Sam;Lee, Sang-Woo;Choe, Zhin-Ryong;Shim, Sang-In
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.1
    • /
    • pp.13-16
    • /
    • 2003
  • Seeds of burcucumber were treated with accelerated aging, cold-stratification, and light quality illuminated during desiccation to enhance their germination and seedling emergence. The germination was increased by aging and cold-stratification although the latter treatment showed greater effectiveness than the former one. In the combined treatment of aging 6 days at $45^{\circ}C$ and cold-stratification, the germination was promoted under longer period of cold-stratification to reach nearly 100% in 3 week cold-stratification on the ninth day from sowing. In the sequentially combined treatment of aging, cold-stratification, and light quality during 24 hour desiccation at $35^{\circ}C$, no-stratified seeds showed the highest rate in red light treatment but the lowest in far-red light. This implies that the phytochrome action run during the desiccation of imbibed seeds. The red light exposure during drying for the cold-stratified seeds after aging accelerated the germination even more than the dark treatment and germinated 100% on the next day of sowing. It is concluded that the sequential treatment of aging, cold-stratification, and red light illumination during desiccation can highly promote percentage and speed of burcucumber seed germination.

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Local Enhancement Mechanism of Cold Surges over the Korean Peninsula (한반도 한파의 지역적 강화 메커니즘)

  • Lee, Hye-Young;Kim, Joowan;Park, In-Gyu;Kang, Hyungyu;Ryu, Hosun
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.383-392
    • /
    • 2018
  • This study investigates synoptic characteristics of cold surges over South Korea during winter season (December-February). A total of 63 cold events are selected by quantile regression analysis using daily mean temperature observations from 11 KMA stations for 38 years (1979/80-2016/17). Large-scale pressure pattern during the cold surges is well characterized by high over Siberia and low over Aleutian regions, which elucidates cold advection over the Korean peninsula. However, the large-scale pattern cannot successfully explain the observed sudden decrease of temperature during the cold surges. Composite analyses reveal that a synoptic-scale cyclone developing over the northern Japan is a key feature that significantly contribute to the enhancement of cold advection by increasing pressure gradient over the Korean peninsula. Enhanced sensible and latent heat fluxes are observed over the southern ocean of Korea and Japan during the cold surges due to temperature and humidity differences between the near surface and the lower atmosphere over the ocean. The evaporated water vapor transported toward the center of the surface cyclone and condenses in the lower-to-middle troposphere. The released energy likely promotes the development of the surface cyclone by inducing positive PV near the surface of the heating region.

Enhancement of the round-trip efficiency of liquid air energy storage (LAES) system using cascade cold storage units

  • Kim, Jhongkwon;Byeon, Byeongchang;Kim, Kyoung Joong;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.45-50
    • /
    • 2020
  • In this research, the variation of round-trip efficiency in a liquid air energy storage system (LAES) is calculated and an optimal configuration is found. The multiple stages of cold energy storage are simulated with several materials that process latent heat at different temperature ranges. The effectiveness in the charging and discharging processes of LAES is newly defined, and its relationship with the round-trip efficiency is examined. According to defined correlation, the effectiveness of the discharging process significantly affects the overall system performance. The round-trip efficiency is calculated for the combined cold energy storage materials of aqueous dimethyl sulfoxide (DMSO) solution, ethanol, and pentane theoretically. The performance of LAES varies depending on the freezing point of the cold storage materials. In particular, when the LAES uses several cold storage materials, those materials whose freezing points are close to room temperature and liquid air temperature should be included in the cold storage materials. In this paper, it is assumed that only latent heat is used for cold energy storage, but for more realistic analyzes, the additional consideration of the transient thermal situation to utilize sensible heat is required. In the case of such a dynamic system, since there is certainly more increased heat capacity of the entire storage system, the volume of the cold energy storage system will be greatly reduced.