• 제목/요약/키워드: coil number

검색결과 286건 처리시간 0.024초

Velocity and temperature profiles of Al/water micro fluid in a circular tube with swirl

  • Chang, Tae-Hyun;Lee, Kwon Soo;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권7호
    • /
    • pp.677-684
    • /
    • 2013
  • A lot study of convection heat transfer on internal flow has been extensively conducted in the past decades using of high specific surface area, increasing heat transfer coefficient, swirling flow and improving the transport properties. This study concerned with the application of a tangential slot swirl generator for improving heat transfer in a horizontal circular copper tube. The Al particles(about $100{\sim}130{\mu}m$) was employed for this experimental work. 3D PIV(particle image velocimetry) technique has employed to measure velocity profiles of Al particles with and without swirl flow. The copper tube is heated uniformly by winding of a heating coil for heat transfer work, having a resistance of 9 ohm per meter. Experiments are performed in the Reynolds number range of 6,800~12,100 with swirl and without swirl using Al particles. Experimental data for comparison of Nusselt number is presented that of with swirl and without swirl along the test tube for the Reynolds numbers. The Nusselt number is improved with increasing of Reynolds numbers or swirl intensities along the test tube. The Nusselt number with swirl flow is about 60.0% to 119.0% higher than that obtained by the Dittus-Boelter equation.

자이로스코프에서 토커의 설계 및 해석 (The Design Method of the Torquer in DTG)

  • 김홍규;정현교;홍선기
    • 한국자기학회지
    • /
    • 제6권1호
    • /
    • pp.48-53
    • /
    • 1996
  • 자이로스코프에서 기울어진 회전자를 바로 세우는 역할을 하는 것이 토커이다. 본 연 구에서는 최대입력각속도 조건을 만족하면서 주어진 자석성능으로 최대의 특성을 낼 수 있는 설계에 대하여 알아보고자 한다. 자이로스코프의 기계적 치수가 결정되면 토커의 치수는 제한된다. 즉 코일이 위치하는 공간이 제한되므로 코일의 굵기가 결정되면 권선수도 정해지게 된다. 이 치수들을 이용하여 토커의 환산계수를 계산한 후, 코 일에 흐를 수 있는 최대 전류를 계산하면, 최대 입력각속도가 계산되어진다. 토커의 특성해석은 3차원 유한요소법을 이용하였으며, 유한요소 해석 결과로부터 토커의 환산 계수를 계산하였다. 실제 제작한 자이로의 성능실험을 통하여 제안된 토커 설계 알고리즘의 유용함을 입증한다.

  • PDF

음향방출기법을 이용한 극저온 환경하에서 초전도 계자코일의 퀀칭탐지 적용에 관한 연구 (Application of Acoustic Emission Technique for On-Line Monitoring of Quench in Racetrack Superconducting Coil at Cryogenic Environment)

  • 이민래;권영길;이준현;손명환
    • 대한기계학회논문집A
    • /
    • 제24권4호
    • /
    • pp.858-865
    • /
    • 2000
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE)echnique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. In addition, the source location of quench in superconducting magnet was also discussed on the basis of correlation between magnet voltage and AE energy.

수치해석을 통한 충격 시 접시 스프링의 비선형 특성 고찰 (Non-linearity characteristics consideration of the Disc Spring under Shock using Numerical Analysis)

  • 방승우;이해진;권오철;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1266-1271
    • /
    • 2007
  • General coil spring has linearity. However, disc spring has non-linearity so that using this non-linearity disc spring can be designed to do shock-absorbing in cases we need because shock response also has non-linearity. By changing the shape and stacking number, it is satisfactory with response of displacement, velocity and acceleration. Conventionally, disc spring was used to control the vibration against huge load and limited space. However, it is limitedly used because of difficulty of the designing guidance. Therefore, disc spring is needed to study further in order to apply it widely. Response of disc spring is compared to response of coil spring by changing ho/t radio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and effect of ho/t and stiffness is analyzed to broad usage so that design factor of disc spring is presented.

  • PDF

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

DESIGN OF A LOW-COST 2-AXES FLUXGATE MAGNETOMETER FOR SMALL SATELLITE APPLICATIONS

  • Kim, Su-Jeoung;Moon, Byoung-Young;Chang, Young-Keun;Oh, Hwa-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권1호
    • /
    • pp.35-46
    • /
    • 2005
  • This paper addresses the design and analysis results of a 2-axes magnetometer for attitude determination of small satellite. A low-cost and efficient 2-axes fluxgate magnetometer was selected as the most suitable attitude sensor for LEO microsatellites which require a low-to-medium level pointing accuracy. An optimization trade-off study has been performed for the development of 2-axes fluxgate magnetometer. All the relevant parameters such as permeability, demagnetization factor, coil diameter, core thickness, and number of coil turns were considered for the sizing of a small satellite magnetometer. The magnetometer which is designed, manufactured, and tested in-house as described in this paper satisfies linearity requirement for determining attitude position of small satellites. On the basis of magnetometer which is designed in Space System Research Lab. (SSRL), commercial magnetometer will be developed.

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

수치해석을 통한 충격 시 접시 스프링의 비선형 특성 고찰 (Non-linearity Characteristics Consideration of the Disc Spring Under Shock Using Numerical Analysis)

  • 방승우;이해진;심현진;박상길;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제18권2호
    • /
    • pp.153-159
    • /
    • 2008
  • General coil spring has linearity. However, disc spring has non-linearity so that using this non-linearity disc spring can be designed to do shock-absorbing in cases we need because shock response also has non-linearity. By changing the shape and stacking number, it is satisfactory with response of displacement, velocity and acceleration. Conventionally, disc spring was used to control the vibration against huge load and limited space. However, it is limitedly used because of difficulty of the designing guidance. Therefore, disc spring is needed to study further in order to apply it widely. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and effect of $h_o/t$ and stiffness is analyzed to broad usage so that design factor of disc spring is presented.

Successful Treatment of a Large Pulmonary Arteriovenous Malformation by Repeated Coil Embolization

  • Park, Jimyung;Kim, Hyung-Jun;Kim, Jee min;Park, Young Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • 제78권4호
    • /
    • pp.408-411
    • /
    • 2015
  • Pulmonary arteriovenous malformations (AVMs) are caused by abnormal vascular communications between the pulmonary arteries and pulmonary veins, which lead to the blood bypassing the normal pulmonary capillary beds. Pulmonary AVMs result in right-to-left shunts, resulting in hypoxemia, cyanosis, and dyspnea. Clinical signs and symptoms vary depending on the size, number, and flow of the AVMs. Transcatheter embolization is the treatment of choice for pulmonary AVMs. However, this method can fail if the AVM is large or has multiple complex feeding arteries. Surgical resection is necessary in those kind of cases. Here, we report the case of a patient with a 6-cm pulmonary AVM with multiple feeding arteries that was successfully treated by repeated coil embolization without surgery.

환형 무전극 형광램프 구동을 위한 전기적, 자기적 특성 분석 (A study on Electrical and Electromagnetic Properties for Driving the Ring-shaped electrodeless fluorescent lamp)

  • 조주웅;이영환;남중희;최용성;김용갑;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.69-72
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, we present measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and number of coil turns using a highly permeable Mn-Zn ferrite. It is found that the impedance are increased while the quality factor decreases as frequency increases.

  • PDF