• Title/Summary/Keyword: coil

Search Result 3,847, Processing Time 0.031 seconds

The study on the methane activation by a plasma (플라즈마 반응에 의한 메탄 활성화에 관한 연구)

  • Cho Won Ihl;Baek Young Soon;Kim Byung Il;Kim Young Chai
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.60-69
    • /
    • 1998
  • Methane, the major constituent of natural gas, had been converted to higher hydrocarbons by microwave and radio-frequency plasma in vacuum condition. Methane had been activated to plasma by suppling high energy then converted to ethane, ethylene, acetylene. The direct conversion process of methane had produced few by-products and demanded low-energy. The plasma sources were microwave and radio-frequency. Two types of reactor had been used to activate methane. One is common single tubular-type reactor and the other is series coil-type reactor which used for the first time in this study. To produce more C2 products, methane had been converted by a plasma and catalyst. The results of this study could be used to study mechanism of plasma reaction of methane, design the plant-scale reactor.

  • PDF

고전압 펄스 시스템 '천둥'을 이용한 N2, SF6 및 혼합기체에서의 전기 방전 현상 연구

  • Byeon, Yong-Seong;Song, Gi-Baek;Hong, Yeong-Jun;Han, Yong-Gyu;Eom, Hwan-Seop;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.102-102
    • /
    • 2010
  • 수 Tera Watt급의 가속기 및 펄스파워 시스템은 다수의 스위치를 사용하고 있으며, 이와 같은 가속기 및 시스템의 성능은 기체방전 스위치의 성능에 직접적으로 관련되어 있다. 일반적으로 이와 같은 기체방전, 액체방전 고출력 스위치는 다목적으로 많은 연구와 개발에 응용되고 있다. 예를 들어 천둥 펄스전자빔 발생장치는 12개의 Marx gap 및 3개의 100 kV 펄스충전 전기트리거 gap을 가지고 있다. 기체 방전 또는 액체 방전 펄스 충전 갭 스위치의 음극에 펄스 고전압이 인가되면 이로 인하여 음극에서 전자빔이 발생한다. 내부에는 전자빔이 양극과 충돌하는 순간 양극표면에 플라스마가 형성된다. 이와 같은 플라스마 sheath는 축 방향 이극관 안에서 양극충전 에서 음극으로 팽창하면서 전파하며, 또한 거의 동시에 음극표면에도 플라스마가 형성되어 음극에서 양극으로도 팽창하여 전파하게 된다. 이와 같은 펄스충전 고출력 갭 스위치 안에서 발생되는 방전 플라스마의 특성에 관한 갭 breakdown 과정에 대한 특성연구를 한다. 고출력스위치의 특성 조건으로는 방전전압, 방전시간, jitter 등이 있다. 본 연구에서는 최대전압 600 KV, 최대전류 88 KA, 펄스 폭 60 ns의 특성을 가지는 고전압펄스 시스템 '천둥'을 이용하여 방전 챔버에 고전압 펄스를 인가하고 N2와 SF6 혼합기체 종류와 압력에 따른 방전 현상을 연구하였다. 전극은 구리텅스텐 합금재질의 표준전극을 사용하였고, 전극 간격은 20 mm로 고정하였다. 방전 챔버 압력을 100 torr에서 4 기압까지 변화시켜가며 실험을 진행하였고, N2에 대한 SF6의 혼합비율을 0%~100%까지 변화시키며 실험을 진행하였다. 방전 챔버에는 C-dot probe와 B-dot probe를 설치하여 전압과 전류를 측정하였고, C-dot probe 와 B-dot probe는 각각 Northstar사의 10000:1 고전압 probe와 rogowiski coil을 이용하여 시준 하였다. 실험결과 방전전압은 압력이 증가함에 따라 증가하다가 2 기압 이상에서는 완만히 증가하는 경향을 보였고, SF6 혼합비율은 0~10%까지 급격히 증가하고, 그 이상의 혼합비율에서는 완만히 증가하였다. 방전개시시간은 혼합기체 압력에 따라 증가하며 1기압 이상에서는 급격히 증가 하였다. SF6 혼합비율에 따라서는 1 기압 조건까지는 큰 차이가 없었으나 2 기압부터는 급격히 증가하였다. 안정성을 나타내는 jitter는 SF6 100%일 때 가장 컸으나 혼합기체의 변화에 따른 큰 차이는 없었다.

  • PDF

The Design of a Wind Speed & Direction Module and a DSP Sensor Interface System for the Meteorological System (기상계측시스템을 위한 풍향.풍속모듈 및 DSP 센서 인터페이스시스템 설계)

  • Song, Do-Ho;Joo, Jae-Hun;Ock, Gi-Tae;Kim, Sang-Gab;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1478-1485
    • /
    • 2007
  • In this paper, a meteorological system including a wind speed & direction module and the DSP(Digital Signal Processor) sensor interface circuit board are proposed. This DSP system accepts and process the informations from a wind speed & direction module, the atmospheric pressure sensor, the ambient air temperature sensor and transfers it to the PC monitoring system. Especially, a wind speed & direction module and a DSP hardware are directly designed and applied. A wind speed & direction module have a construction that it have four film type RID(Resistive Temperature Detectors) resistive sensor adhered around the circular metal body heated constantly by heating coil for obtaining vector informations about wind. By this structure, the module is enabled precise measurement having a robustness about vibration, humidity, corrosion. A sensor signal processing circuit is using TMS320F2812 TI(Texas Instrument) Corporation high speed DSP. An economical meteorological system could be constructed through the data from wind speed & direction module and by the fast processing of DSP interface circuit board.

A Study on the Development of Power-Line EMI Filter for the Prevention of Conduction Noise by Coil Loads. (코일성 부하에 의한 전도 노이즈 방지 목적의 전원용 EMI필터 개발 연구)

  • Kim, Byeong Jun;Joo, Jae-hun;Kim, Jin Ae;Baek, Pan Keun;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.175-179
    • /
    • 2009
  • this paper proposes a filter design that makes to be satisfied EMC spec. in reliability test of analogue switch for electronic equipment and air conditioning load unit. A designed electromagnetic wave filter was applied to minimize an mutual interference and surrounding environment and improve the product's quality being satisfied to EMC standard. By simulation, using a spectrum analyzer at the 30MHz~1GHz band, ISO/JASO standard frequency range, and simplified EMI chamber, energy distribution of a specific frequency band was analyzed and the capacity of the element which composed the filter was determined in order to implement the most suitable electromagnetic wave filter.In fact, it was certificated that noise decrease by filter addition to the analogue switch for electronic equipment and air conditioning load unit in Certification Authority, and confirmed that the unit is carried out a normal action without electromagnetic wave interference.

  • PDF

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • v.7 no.5
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

The Antimicrobial Effects of Natural Aromas for Substitution of Parabens (합성 항균제를 대체하기 위한 천연물질의 항균 효과)

  • 조춘구;김봉남;홍세흠;한창규
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.1
    • /
    • pp.166-185
    • /
    • 2002
  • Aroma oils extracted from the natural material have antibacterial, antivirus, antiinflammatory, and preservative effect. The preserve efficacy testing between aroma oils and parabens as an artificial preservative had been performed and then it had been suggested that aroma oil was possibile to apply to the cosmetics. Aroma oils were pine, rosemary, lemon and eucalyptus, and parabens were methylparaben, blitylparaben. Antiseptic concentrations of aroma oils and parabens having 0.0, 0.1, 0.2, 0.4, 0.8, 1.0wt% were tested respectively. Escherichia coil(ATCC No.8739), Pseudomonas aeruginosa(ATCC No. 9027) which are gram-negative and Staphylococcus aureus (ATCC No. 6538), Bacillus subtilis(ATCC No. 6633) which are gram-positive were used as the test organisms. Disk paper and broth dilution methods were used as the methods of preservative efficacy testing. The antibacterial activity of aroma oils and parabens for gram-positive were better than that for gram-negative. For the antibacterial activity aroma oils were better than parabens. Among the aroma oils, rosemary and pine having superior antibacterial activity were selected and blended to illuminate if there is any synergy, There was synergical effect and optimum ratio of aroma blend is 3 : 1(rosemary pine) in this study.

Evaluation of Diagnostic Reference Level in Interventional Procedures (인터벤션시술 진단참고수준 평가)

  • Kang, Byung-Sam;Park, Hyung-Shin
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.451-457
    • /
    • 2021
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure and patient radiation exposure is also increasing accordingly. In this study, we evaluated the patient dose of major interventional procedures nationwide and we established our Korean database. With these results, we tried to suggest the reference dose level for major interventional procedures. We evaluated patent dose data in the field of interventional radiology from foreign countries. Measurement of radiation dose exposure for 11 major interventional procedures was conducted using embedded DAP meters in 10,006 patients from 47 hospitals, and reference level of each interventional procedure was suggested. The DRLs of each intervenional procedure are as follows: TACE 206(Gy·cm2), AVF 12(Gy·cm2), LE intervention 43(Gy·cm2), TFCA 122(Gy·cm2), Cerebral aneurysm coil embolization 214(Gy·cm2), PTBD 22(Gy·cm2), Biliary stent 60(Gy·cm2), PCN 7(Gy·cm2), Hickman catheter 2.1(Gy·cm2), Chemoport 1.4(Gy·cm2), BAE 104(Gy·cm2). Compared with the previously established DRL in 2012, the radiation dose decreased in all 10 interventional procedures. In the future, continuous publicity and education on the radiation dose reduction will be needed.

Comparison of the effects of horizontal and vertical micro-osteoperforations on the biological response and tooth movement in rabbits

  • Kim, Seok-gon;Kook, Yoon-Ah;Lim, Hee Jin;Park, Patrick;Lee, Won;Park, Jae Hyun;Bayome, Mohamed;Kim, Yoonji
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.304-312
    • /
    • 2021
  • Objective: This study aimed to compare the amount of tooth movement after multiple horizontal (MH) and single vertical (SV) micro-osteoperforations (MOPs), and evaluate the histological changes after orthodontic force application in rabbits. Methods: The mandibles of 24 white rabbits were subjected to two experimental interventions: MH and SV MOPs. Defect volume of the MOPs between the two groups was kept similar. A force of 100 cN was applied via a coil spring between the incisor teeth and the first premolars. The amount of tooth movement was measured. Differences in the amount of tooth movement and bone variables at three time points and between the two groups were evaluated using repeated-measures analysis of variance. Results: The first premolar showed a mesial movement of 1.47 mm in the MH group and 1.84 mm in the SV group, which was significantly different at Week 3 (p < 0.05). No significant difference was observed in bone volume and bone fraction between the groups. Tartrate-resistant acidic phosphatase-positive cell count was also significantly greater at Week 3 than at Week 1 in both the SV and MH groups. Conclusions: The amount of tooth movement showed significant differences between Weeks 1 and 3 in the SV and MH MOP groups, but showed no differences between the two groups. Therefore, SV MOP could be considered an effective tool for enhancing tooth movement, especially for molar distalization, uprighting, and protraction to an edentulous area.

The Fate of Partially Thrombosed Intracranial Aneurysms Treated with Endovascular Intervention

  • Lee, Jeongjun;Cho, Won-Sang;Yoo, Roh Eul;Yoo, Dong Hyun;Cho, Young Dae;Kang, Hyun-Seung;Kim, Jeong Eun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.427-436
    • /
    • 2021
  • Objective : The fate of partially thrombosed intracranial aneurysms (PTIAs) is not well known after endovascular treatment. The authors aimed to analyze the treatment outcomes of PTIAs. Methods : We retrospectively reviewed the medical records of 27 PTIAs treated with endovascular intervention between January 1999 and March 2018. Twenty-one aneurysms were treated with intraluminal embolization (ILE), and six were treated with parent artery occlusion (PAO) with or without bypass surgery. Radiological results, clinical outcomes and risk factors for major recurrence were assessed. Results : The initial clinical status was similar in both groups; however, the last status was better in the ILE group than in the PAO group (p=0.049). Neurological deterioration resulted from mass effect in one case and rupture in one after ILE, and mass effect in two and perforator infarction in one after PAO. Twenty cases (94.2%) in the ILE group initially achieved complete occlusion or residual neck status. However, 13 cases (61.9%) showed major recurrence, the major causes of which included coil migration or compaction. Seven cases (33.3%) ultimately achieved residual sac status after repeat treatment. In the PAO group, all initially showed complete occlusion or a residual neck, and just one case ultimately had a residual sac. Two cases showed major recurrence, the cause of which was incomplete PAO. Aneurysm wall calcification was the only significantly protective factor against major recurrence (odds ratio, 36.12; 95% confidence interval, 1.85 to 705.18; p=0.018). Conclusion : Complete PAO of PTIAs is the best option if treatment-related complications can be minimized. Simple fluoroscopy is a useful imaging modality because of the recurrence pattern.

Improvement of Low Speed Stability of CMG Gimbal Using Full-pitch Distributed Winding (전절권 분포형 권선을 통한 제어모멘트자이로 김블의 저속 안정성 개선 연구)

  • Lee, Jun-yong;Lee, Hun-jo;Oh, Hwa-suk;Song, Tae-Seong;Kang, Jeong-min;Song, Deok-ki;Seo, Joong-bo
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • The electromagnetic forces generate a torque on the gimbal motor, and changes in the coil current causes torque ripple. This affects the gimbals' speed and results to unstable satellite attitude. It is therefore essential to reduce the torque ripple of the gimble motor with the aim of improving the attitude control accuracy of the satellite. This paper theoretically analyzes the torque generated from the modeling of a motor for general concentrated winding and distributed winding. The prototype was designed and fabricated through selection of the winding that reduces the torque ripple through simulation results. The results of the magnetic fields' theoretical analysis and the back electromotive force of the prototype were compared with the calibrated results for verification of conformity and manufacture of the design. The low-speed test proved that the torque ripple is reduced by improving the speed stability.