• Title/Summary/Keyword: coefficients of determination

Search Result 759, Processing Time 0.03 seconds

Simulation-Based Determination of Hydrodynamic Derivatives and 6DOF Motion Analysis for Underwater Vehicle (시뮬레이션 기반 수중 운동체의 유체력 미계수 결정 및 6자유도 운동해석)

  • Go, Gwangsoo;Ahn, Hyung Taek;Ahn, Jin-Hyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • This paper introduces a simulation-based determination method for hydrodynamic derivatives and 6DOF (degrees-offreedom) motion analysis for an underwater vehicle. Hydrodynamic derivatives were derived from second-order modulus expansion and composed of the added mass, and linear and nonlinear damping coefficients. The added mass coefficients were analytically obtained using the potential theory. All of the linear and nonlinear damping coefficients were determined using CFD simulation, which were performed for various cases based on the actual operating condition. Then, the linear and nonlinear damping coefficients were determined by fitting the CFD results, which referred to 6DOF forces and moments acting on an underwater vehicle, with the least square method. To demonstrate the applicability of the current study, 6DOF simulations for three different scenarios (L-, U-, and S-turn) were carried out, and the results were validated on the basis of physical plausibility.

Verification of Reproducibility of VCS2000 Equipment for Mechanical Measurement of Korean Landrace×Yorkshire (F1), F1×Duroc (LYD) Pig Carcasses

  • Yunhwan Park;Kwantae Kim;Jaeyoung Kim;Jongtae Seo;Jungseok Choi
    • Food Science of Animal Resources
    • /
    • v.43 no.4
    • /
    • pp.553-562
    • /
    • 2023
  • With an increase in meat consumption, the need to measure the weight of each primal cut of pork has increased. Recently, automation devices have been used to measure the weight of each primal cut of pork. The objective of this study was to investigate the accuracy of VCS2000, one of the non-invasive pig carcass analyzers. Production levels of 7 primal cuts of 50 pigs were measured with VCS2000. Average error rates between dissected value for each primal cut and VCS2000 measurement values of ham, shoulder picnic, belly, loin, and shoulder blade were around 5%. Average error rates for spare rib and tenderloin were about 10%. Correlation coefficients between the dissected value and the VCS2000 measured value for ham, shoulder picnic, loin, belly, and shoulder blade were high at 0.66-0.83. Correlation coefficients of spare rib and tenderloin were low at 0.35 and 0.47. Coefficient of determination of the VCS2000 measured value for each primal cut by regression analysis was 0.77 or more for ham, shoulder picnic, loin, and shoulder blade and 0.63 for belly. Coefficients of determination for spare rib and tenderloin were low at 0.40 and 0.27. In addition, the coefficient of determination of VCS2000 for each primal cut was higher than that of the dissected value for all primal cuts. In conclusion, pig carcass analysis using the VCS2000 has a high reliability for pork cuts with high production levels, but a relatively low reliability for pork cuts with low production levels and high fat levels.

Determination of Wind Pressure Coefficients around Prismatic Structures with Different Aspect Ratios (종횡비 변화에 따른 사각주형 구조물주위의 풍압계수 결정)

  • Suh, S.H.;Lee, K.Y.;Yoo, S.S.;Roh, H.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.52-62
    • /
    • 1995
  • The purpose of this study is to determine the wind pressure coefficients around prismatic structures with different aspect ratios. Air flows around a model of prismatic shape are investigated experimentally in the wind tunnel and simulated using finite volume method. Pressure distributions and the corresponding pressure coefficients are calculated from the experimental and numerical results. The effects of aspect ratios on the pressure coefficients are discussed extensively. The numerical results are compared with those of experiments. The simulated and experimental results for average wind pressure coefficients are considerably lower than those defined in the Korean Architectural Standard Code.

  • PDF

A Study on Determination of PID Coefficients by Deriving Temperature Stabilization Transfer Function and it's Simulation (온도 안정화 전달함수 도출 및 이의 시뮬레이션에 의한 PID 계수 결정에 관한 연구)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.412-418
    • /
    • 2015
  • In this paper, a new method for obtaining PID coefficients which are essential to a temperature stabilization process has been proposed. This method starts from measuring the open loop transfer function of the module, then the closed loop transfer function embodying PID control can be produced based on this. Finally, the simulations using a few PID coefficients and the performance analysis for those results provide the best PID coefficients which are effective in a fast setting to a target temperature, a less current needed, and less deviation from steady state. The measurement using the derived PID coefficients, $K_p=1.6$,$K_i=0.8$,$K_d=0.3$ showed $T_s=7.4[sec]$, %OS = 16, and stabilization within ${\pm}0.02[^{\circ}C]$ for several hours. In addition to light sources like SOA, the proposed method can be utilized for any device needs temperature stabilization.

Studies on Development of Microplate-EIA for the Determination of Serum Progesterone (혈청 Progesterone 측정을 위한 효소면역분석법 개발에 관한 연구)

  • 김정우;이욱연
    • Korean Journal of Animal Reproduction
    • /
    • v.17 no.4
    • /
    • pp.347-356
    • /
    • 1994
  • A simpled and sensitive microplate enzyme immunoassay(EIA) was developed for the determination of progesterone concentration in serum, based on progesterone monoclonal antibody as anti-progesterone, horseradish peroxidase(HRP) as enzyme-label and tetramethylbenzidine(TMB) as substrate. The assay has a sensitivity of 5 pg-120pg/well and intra- and inter-assay coefficients of variation for progesterone standard curve (1.0ng~10.0ng/ml) were ranged 2.5~9.9% and 1.7.8.0%, respectively, determination coefficient of the regressio equation of our standard curve(R2=0.990$\pm$0.007) were high, and this is the same level as that of commercial kit(Hormonost Bio-Lab, Germany, R2=0.98~0.99). The progesterone concentration of serum determined by both kits (Work & Bio-Lab) were significantly correlated (r=0.95, P<0.01) although a little higher value were resulted in our kit than that of commercial kit. It generally is these results indicated that the microplate-EIA can be cused for the determination of progesterone in serum, as well as, for the determination of the early pregnancy diagnosis.

  • PDF

Organic Pollutant Transport in Unsaturated Porous Media by Atmospheric Breathing Processes( I ) - Partition Coefficient -

  • Ja-Kong;Lim, Jae-Shin;Do, Nam-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.11a
    • /
    • pp.50-53
    • /
    • 1996
  • This paper reports the experimental results for the determination of the overall partition coefficient of VOCs in unsaturated soil, A chromatographic method was used for the determination of gaseous partition coefficients to natural soil under various water content conditions. The equilibrium vapor pressure of water over saturated salt solution was used to fix the relative humidity of the air and control the water content of the soil systems. The transport behavior was studied for dichloromethane, trichloroethane and dichlorobenzene pollutants, with log octanol-water partition coefficients(log $K_{ow}$ ) which range from 1.25 to 3.39, or water to soil partitioning which varies by 135 times; water solubility constants which vary by 3 times; and vapor pressures which range from 1 to 362 torr. Water content of the soil had a pronounced effect on the effective partition coefficient(between gas and soil + water stationary phase) as well as on the effective dispersion coefficient.

  • PDF

DETERMINATION OF ATMOSPHERIC EXTINCTION COEFFICIENT AT BOHYUNSAN OPTICAL ASTRONOMY OBSERVATORY (보현산 천문대의 대기 소광계수)

  • Kim, Kang-Min;Son, Dong-Hoon;Hyung, Siek;Yoon, Tae-Seog
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.167-172
    • /
    • 1997
  • Detailed low spectral resolution observations of the spectrum have been made for three early spectral type standard stars, HR718, HR1544, HR3454, respectively, for the wavelength region 4,300 A to 7,500 A, using the Bohyunsan Optical Astronomy Observatory (BOAO) Middle- Dispersion Spectrograph. These standard stars were chosen from well-known bright northern standard stars. All of the observed long slit spectral data has been reduced and analyzed using the IRAF reduction procedure. The derived extinction coefficients are compared with the other observatory result. The derived value can be used in the determination of flux calibration of BOAO spectroscopic observation. However, until the high quality data are secured from a new series of observation in the blue region and are re-analyzed together, the extinction coefficients below the 4,000 A wavelength remains unknown.

  • PDF

Determination of escape rate coefficients of fission products from the defective fuel rod with large defects in PWR

  • Pengtao Fu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2977-2983
    • /
    • 2023
  • During normal operation, some parts of the fission product in the defective fuel rods can release into the primary loops in PWR and the escape rate coefficients are widely used to assess quantitatively the release behaviors of fission products in the industry. The escape rate coefficients have been standardized and have been validated by some drilling experiments before the 1970s. In the paper, the model to determine the escape rate coefficients of fission products has been established and the typical escape rate coefficients of noble gas and iodine have been deduced based on the measured radiochemical data in one operating PWR. The result shows that the apparent escape rate coefficients vary with the release-to-birth and decay constants for different fission products of the same element. In addition, it is found that the escape rate coefficients from the defective rod with large defects are much higher than the standard escape rate coefficients, i.e., averagely 4.4 times and 1.8 times for noble gas and iodine respectively. The enhanced release of fission products from the severe secondary hydriding of several defective fuel rods in one cycle may lead to the potential risk of the temporary shutdown of the operating reactors.