• Title/Summary/Keyword: coefficient of wettability

Search Result 29, Processing Time 0.028 seconds

Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube (수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향)

  • 황규대;박노성;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

Effects of Static Contact Angle and Roughness on Rolling Resistance of Droplet (액적의 구름저항에 대한 정접촉각 및 거칠기의 영향)

  • Cho, Won Kyoung;Cho, Sang Uk;Kim, Doo-In;Kim, Dae-Up;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 2016
  • In this study, the effects of the contact angle (CA) and contact angle hyteresis (CAH) of planar and nano-patterned surfaces on rolling resistance of water droplet were studied. Based on the investigation on the CAH of water droplet on surfaces with various static wettability, it was found that the rolling resistance coefficient of water droplet is highly influenced by the surface pattern as well as CAH. The observed results suggest that the optimal surface patterns should be designed in order to minimize the rolling resistance of water droplet for the practical applications where superhydrophocitiy is required.

Mechanical Properties of High-Hardness TiNX Thin Films Deposited by Pure Nitrogen Plasma Using Magnetron Sputtering Deposition (마그네트론 스퍼터링 증착법을 사용하여 순수한 질소 플라즈마에 의해 성막된 고경도 TiNX 박막의 역학적 특성)

  • Lee, Chang-Hyun;Rhee, Byung-Roh;Bae, Kang;Park, Chang-Hwan;Kim, Hwa-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.8
    • /
    • pp.514-519
    • /
    • 2017
  • TiN (titanium nitride) films were prepared using the RF magnetron sputtering technique. The films were deposited by pure $N_2$ plasma sputtering. Their mechanical properties, such as nano-indentation hardness, friction coefficient, and surface wettability, have been investigated. X-ray diffraction (XRD) studies revealed that the orientation of $TiN_X$ films changed towards the (111) orientation with decreasing working pressure due to a strong compressive stress during deposition. The strongest TiN (111) orientation was found when the film was deposited at a working pressure of 1 Pa. This film showed the largest hardness (16 GPa) and smallest friction coefficient (0.17) among the studied samples. Moreover, this film was found to be accompanied by a water-repellent surface with water contact angle more than $100^{\circ}$.

Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Horizontal Tubes (친수성 표면처리가 수평관 외벽의 증발열전달에 미치는 영향)

  • 박노성;황규대;강병하;정진택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.525-532
    • /
    • 2000
  • Evaporation heat transfer characteristics have been investigated experimentally when distilled water is sprayed on the outside wall of horizontal tubes in a evaporator. This problem is of particular interest in the design of evaporator of an absorption system. Hydrophilic surface treatment was employed to increase the wettability on copper tubes. The results indicate that evaporation heat transfer with hydrophilic tubes is shown to be 25-44% higher than that with bare tubes at evaporation pressure of 31.8 Torr(evaporation temperature$ 30^{\circ}C). Evaporation heat transfer rates of hydrophilic treatment tubes are improved substantially, comparing with those of conventional copper tubes in the wide range of operating parameters, such as water inlet temperatures, water mass flow rates and evaporation pressures.

  • PDF

Influence of Spring on The Absorption Performance of a Vertical Absorber Tube (수직 흡수전열관의 흡수성능에 미치는 스프링의 영향)

  • 김정국;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.825-832
    • /
    • 2002
  • The present study investigated the enhancement of the absorption performance by the spring wrapped around the outer surface of the vertical falling film absorber tube. Heat and mass transfer enhancements were experimentally investigated, and flow visualization was performed to observe the wettability and flow pattern of the solution. The key experimental parameters were spring diameter (0.5, 1.0 mm) and spring pitch (1, 3, 10 mm), film Reynolds number (50~150), and concentration of LiBr-$H_2O$ solution (55, 60, 65 wt%). As the spring diameter was increased, the absorption mass flux, Sherwood number, Nusselt number, heat flux, and heat transfer coefficient were increased The Nusselt and Sherwood numbers showed the maximum at the spring pitch of 3mm, and the ratio of pitch to diameter of approximately 3 and 6 for the spring diamter of 0.5 mm, respectively.

Bonding Mechanism and Strength of Metals to Ceramics (금속과 세라믹의 접합기구와 접합강도)

  • Kee, Se-Ho;Jung, Jae-Pil;Kim, Won-Joong
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.40-46
    • /
    • 2014
  • Bonding technology and bonding mechanism of metal to ceramic including brazing, diffusion bonding, friction welding and etc were reviewed in this study. Various factors should be considered from a bonding design step to acquire a good bonding joint because of a large difference between metal and ceramic in crystal lattice, coefficient of thermal expansion and various properties. In addition, metal and ceramic bonding technologies are constantly being developed according to precise components, multi-function and application to harsh environment. However, improvement of bonding properties and bonding reliability also should be accompanied. Bonding of ceramics, such as $ZrO_2$, $Ti_3AlC_2$ and SiC, to metals like Ti-alloy, TiAl and steel were described in this paper.

A Study on the Surface Modification of Polyimide Film by ion Implantation (이온주입법에 의한 폴리이미드 박막의 표면개질에 대한 연구)

  • Kim, J.T.;Yuk, J.H.;Park, J.K.;Hwang, M.H.;Lim, H.C.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1546-1548
    • /
    • 1997
  • We investigated microhardness, friction, wear and wettability of polyimide for finding out the influence of ion implantation on surface properties. For increasing doses microhardness increased. A reduction of the friction coefficient was most cases correlated with a reduction of wear. The contact angles of water for $B^+$, $N^+$ implanted polyimide decreased from $76^{\circ}$ to zero, as the fluences increased energy of 50, 200 keV.

  • PDF

Understanding of Protein Adsorption to Contact Lens Hydrogels with Varying Surface Energy (콘택트렌즈용 하이드로젤 계면에너지에 따른 단백질 흡착현상의 이해)

  • Jeon, So-Ha;Noh, Hye-Ran
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.338-343
    • /
    • 2012
  • Interfacial properties of commercially available soft contact lens hydrogels were studied to understand thermodynamic phenomena of protein adsorption. Hydrogel particles ($1{\times}1mm^2$) with varying water wettability were exposed to bovine serum albumin solutions for an hour. The remained albumin solutions were analyzed with Bradford assay method. The amount of protein adsorbed to hydrogels increased with protein solution concentrations following Langmuir isotherm. The partition coefficient ($P$) and Gibbs free energy cost of dehydrating the surface region by protein displacement upon adsorption increased with increasing hydrophilicity of contact lens. Understanding of physical chemistry in protein adsorption to contact lens materials enabled elucidating relationships between surface energy and albumin adsorption capacity.

Tribological Behavior of DLC Coatings at Various Humidities (습도에 따른 DLC 코팅의 마찰 거동)

  • Jo, Gyeong-Man;An, Hyo-Seok;Kim, Dae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1842-1848
    • /
    • 2002
  • Although DLC coatings have good tribological properties, these are dependant on the deposition method, the property of contact surface, and test condition. Humidity, which has little influence on tribological behavior in macro scale, is an important factor of tribological behavior in small devices like MEMS. The objective of this study is to investigate the tribological behavior of DLC coatings with particular attention to their wettability at various humidities. DLC coatings were deposited on Si substrates and tested using a reciprocating friction tester against Si$_3$N$_4$balls at various humidities. The results showed that the tribological behavior of DLC coatings was dependant on relative humidity and wettablility of DLC coatings. Friction coefficient at high relative humidity was higher thar that at low relative humidity. The tungsten-containing DLC coatings had a good wear resistance at low relative humidity whereas DLC coatings derived from argon(Ar)+cesium(Cs) gases showed a good wear resistance at high relative humidity.

Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Enhanced Tubes (가공관의 외벽에서 친수성 표면처리가 증발열전달에 미치는 영향)

  • Park, No-Seong;Hwang, Gyu-Dae;Kim, Ho-Yeong;Gang, Byeong-Ha;Jeong, Jin-Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.666-672
    • /
    • 2001
  • Experiments have been carried out to investigate the evaporation heat transfer characteristics of various tubes on which hydrophilic surface treatment using plasma was employed. Spiral, corrugated and low-finned tubes were selected as test tubes. The evaporator tubes were bundled to form three rows of tubes connected in series, with each row being 400mm long. The results obtained indicate that hydrophilic treated tubes tested exhibit better evaporation heat transfer performance as compared with untreated tubes. It is found that the high wettability of the surface obtained through hydrophilic treatment induces film flow onto the tubes during the evaporation process, while sessile drops are formed on untreated tubes.