• Title/Summary/Keyword: coefficient of $CO_2$

Search Result 1,209, Processing Time 0.025 seconds

Development of Hybrid Induction Heating System for Laser Printer

  • Chae Young-Min;Kwon Joong-Gi;Han Sang-Yong;Sung Hwan-Ho
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.178-185
    • /
    • 2006
  • Recently, the demand for the development of high quality and high-speed laser printers and efficient power utilization has required. Among complicated electro-mechanic devices in laser printers, the toner-fusing unit consumes above 90[%] of all electrical energy needed for printing devices. Therefore, the development of a more effective energy-saving toner fusing process becomes a significant task in great demand. Generally, there are several ways to implement a fusing unit. Among them this paper presents a new induction heating method. The proposed induction heating method enables the increase of coupling coefficient between heating coil and heat roller which also increases total energy transfer efficiency. Therefore, the proposed IH (Induction Heating) inverter system provides very fast W.U.T. (Warm UP Time) as well as higher efficiency. Through experimental results, the proposed control system is verified.

Experimental Study on the Heating Performance of a Variable Speed CO2 Heat Pump with a Variation of Operating Conditions (가변속 이산화탄소 열펌프의 난방성능 특성에 관한 실험적 연구)

  • Cho, Hong-Hyun;Lee, Ho-Sung;Jang, Yong-Hee;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.8
    • /
    • pp.694-701
    • /
    • 2007
  • The applications of a transcritical $CO_2$ cycle into water heaters show advantages over conventional systems in the respect of power consumption and heating efficiency because the $CO_2$ cycle has a high compressor discharge temperature. Besides, the heating performance of the transcritical $CO_2$ cycle can be improved by optimizing operating conditions. In this study, the heating performance of a variable speed $CO_2$ heat pump was measured and analyzed by varying refrigerant charge amount, EEV opening, compressor frequency and outdoor temperature. As a result, the optimum normalized charge for heating was 0.226. The COPs at the compressor frequencies of 40, 50 and 60 Hz were 2.94, 2.75 and 2.25, respectively. The heating performance of the $CO_2$ cycle with charge amount was more sensitive than the cooling performance. Moreover, the heating performance was improved significantly by optimizing of compressor frequency and EEV opening.

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.1
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

Magnetoelectric Effect in$CoFe_2O_4-PZT$Composites ($CoFe_2O_4-PZT$ 복합체의 Magnetoelectric 효과)

  • 최임구;권순주;박수현;정윤희
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.6
    • /
    • pp.285-292
    • /
    • 1997
  • We have studied magnetoelectric effect with cobalt ferrite-Pb(Zr, Ti) $O_3$ composites made by solid state reaction. The maximum magnetoelectric voltage coefficient, $(dE/ dH)_{max}$, increased with longer sintering time and higher volume fraction of the cobalt ferrite. The magnetic field for $(dE/ dH)_{max}$ became lower with increasing the sintering time and decreasing the volume fraction of the cobalt ferrite. The phenomena were explained in terms of grain size change, mechanical coupling efficiency, easiness of magnetization and polarization. We obtained the highest magnetoelectric voltage coefficient of 0.174V/cm-Oe, which is about 30% higher than the best value reported.

  • PDF

End bearing Behavior of Open-ended Steel Pipe Piles Resting on Harden Cement Milk (시멘트밀크 고결체 위에 강관말뚝 선단 매입된 말뚝거동)

  • Park, Young-Ho;Kim, Sung-Hwan;Kim, Nag-Young;Kim, Hong-Jong;Park, Yong-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1140-1147
    • /
    • 2010
  • To find the soil plug of steel piles shaped by jet grouting, 4 blocks of cement milk with cube of 1.2m were made. 4 open-ended steel piles on the blocks were rested. The inner end part of 2 the piles was not reinforced. Cement milk 65%(SIG-1) and 100%(RJP-1) were filled into the block and height of 4.2 times of inner the pile diameter respectively. And the other the piles were welded 2 steel ring. The filling of the cement milk was an equal method as before(SIG-2 and RJP-2). Also the strain gauges were installed and the static pile load tests were done at the piles all. As a result, list in great order for effect of soil plug was (1)SIG-1, (2)SIG-2, (3)RJP-1, (4)RJP-2. This is because of strength and filling height of cement milk. And the higher the strength is, the greater the confining coefficient is.

  • PDF

Correlation Analysis between Global Warming Index and Its Two Main Causes (space weather and green house effects) from 1868 to 2005

  • Moon, Yong-Jae
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.24.2-24.2
    • /
    • 2008
  • We have examined the relative contributions of representative space weather proxies (geomagnetic aa index) to global warming (Global temperature anomaly) and compared them with that of green house effect characterized CO2 content from 1868 to 2005. For this we used Hadcrut3 temperature anomaly (Ta) data, aa index taken at two anti-podal subauroral stations (Canberra Australia and hartland England), and the CO2 data come from historical ice core records. From the comparison between Ta and aa index, we found several interesting results: (1) the linear correlation coefficient between two parameters increases until 1990 and then decreases rapidly, and (2) the scattered plots between two parameters shows different patterns before and after 1990. A partial correlation of Ta and two quantities (aa, CO2) also shows that the geomagnetic effect (aa index) is dominant until about 1990 and the CO2 effect becomes much more important after then. These results imply that the green house effect become very important since at least 1990. For a further analysis, we simply assume that Ta (total) = Ta (aa) + Ta (CO2) and made a linear regression between Ta and aa index from 1868 to 1990. A linear model is then made from the linear regression between energy consumption (a proxy of CO2 effect) and Ta (total) - Ta (aa) since 1990. This linear model makes it possible to predict the temperature anomaly in 2030, about 1 degree higher than the present temperature, which is much larger than in the previous century.

  • PDF

Analysis of the Relationship between CO2 Emissions, OCO-2 XCO2 and SIF in the Korean Peninsula (한반도 지역에서 CO2 배출량과 OCO-2 XCO2 및 SIF의 관계성 분석)

  • Yeji Hwang;Jaemin Kim;Yun Gon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.169-181
    • /
    • 2023
  • Recently, in order to reduce carbon dioxide (CO2) emissions, which is the main cause of global warming, Korea has declared carbon emission reduction targets and carbon neutral. Accurate assessment of regional emissions and atmospheric CO2 concentrations is becoming important as a result. In this study, we identified the spatiotemporal differences between satellite-based atmospheric CO2 concentration and CO2 emissions for the Korean Peninsula region using column-averaged CO2 dry-air mole fraction from the Orbiting Carbon Observatory-2 and emission inventory. And we explained these differences using solar-induced fluorescence (SIF), a photosynthetic reaction index according to vegetation growth. The Greenhouse Gas Inventory and Research Center (GIR) and Emissions Database for Global Atmospheric Research (EDGAR) emissions continued to increase in Korea from 2014 to 2018, but the satellite-based atmospheric CO2 concentration decreased in 2018, respectively. Regionally, GIR and EDGAR emissions increased in 2018 in Gyeonggi-do and Chungcheongbuk-do, but satellite-based CO2 concentrations decreased for the corresponding years. In addition, the correlation analysis between emissions and satellite-based CO2 concentration showed a low correlation of 0.22 (GIR) and 0.16 (EDGAR) in Seoul and Gangwon-do. Atmospheric CO2 concentrations showed a different correlation with SIF by region. In the CO2-SIF correlation analysis for the growing season (May to September), Seoul and Gyeonggi-do showed a negative correlation coefficient of -0.26, Chungcheongbuk-do and Gangwon-do showed a positive correlation coefficient of 0.46. Therefore, it can be suggested that consideration of the CO2 absorption process is necessary for analyzing the relationship between the atmospheric CO2 concentration and emission inventory.

Influence of Dy Doping on Electrical Properties and dc Aging Behaviors of Zn-Pr-Co-Cr System

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.234-240
    • /
    • 2007
  • The electrical properties and dc aging behavior for specified stress state of system, which is composed of quaternary Zn-Pr-Co-Cr, were investigated for different $Dy_2O_3$ addition doping level. As $Dy_2O_3$ doping level increased, the density decreased in the range of 5.51-4.90 $g/cm^3$, reaching maximum at 0.5 mol% and the average ZnO grain size decreased in the range of 17.7-6.0 ${\mu}m$. The incorporation of $Dy_2O_3$ significantly improved the non-ohmic properties, above 30 in non-ohmic coefficient, compared with that of undoped samples. The samples with the best performance of non-ohmic properties were obtained for $Dy_2O_3$ doping level of 1.0 mol%, with 49 in non-ohmic coefficient and 2.6 ${\mu}A/cm^2$ in leakage current. The samples with the highest stability were obtained for $Dy_2O_3$ doping level of 0.5 mol%.

Effect of elasticity of aqueous colloidal silica solution on chemical absorption of carbon dioxide with 2-amino-2-methyl-1-propanol

  • Park, Sang-Wook;Choi, Byoung-Sik;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.3
    • /
    • pp.133-141
    • /
    • 2006
  • Carbon dioxide was absorbed into the aqueous nanometer sized colloidal silica solution of 0-31 wt% and 2-amino-2-methyl-1-propanol of $0-2kmol/m^3$ in a flat-stirred vessel with the impeller of various sizes and speeds at $25^{\circ}C$ and 0.101 MPa to measure the absorption rate of $CO_2$. The volumetric liquid-side mass transfer coefficient$(k_La)\;of\;CO_2$ was used to obtain the empirical correlation formula containing the rheological behavior of the aqueous colloidal silica solution. Reduction of the measured $k_La$ was explained by the viscoelastic properties of the aqueous colloidal silica solution. The theoretical value of the absorption rate of $CO_2$ was estimated from the model based on the film theory accompanied by chemical reaction and compared with the measured value.

The Thermal-Hydraulic Effects of Thimble Plug Removal for Westinghouse type PWR Plants

  • B. S. Jun;Park, E. J.;Kim, K. H.;Park, B. S.;K. L. Jeon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.166-172
    • /
    • 1996
  • The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for Westinghouse type PWR plants as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increase approximately by 1.2%. The resulting DNBR penalties can be covered within the current DNBR margin. Accident analyses are also investigated and the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation.

  • PDF