• Title/Summary/Keyword: code phase

Search Result 891, Processing Time 0.024 seconds

Performance Evaluation of Multi-Phased MC-CD74A System for transmitting the High Rate Data (고속데이터 전송을 위한 Multi-Phased MC-CDMA 시스템의 제안 및 성능 분석)

  • 안철용;안치훈;김동구;류승문
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12B
    • /
    • pp.1637-1647
    • /
    • 2001
  • Multi-Code CDMA (MC-CDMA) can not only be integrated easily with a conventional system, but also achieve good spectral efficiency and high processing gain. However, it suffers from high value of peak-to-average power ratio (PAPR). In this paper, we propose the Multi-Phase CDMA (MP-CDMA) system that can provide variable rate service and is not susceptible to the non-linear characteristics of amplifier. The clipping is introduced between at the output of multi-code modulator and at the input of MPSK modulator in order to improve the performance of MPSK chip demodulator and reduce the system complexity, The system performances are compared for the different Number of codes and different clipping levels, respectively. The optimum clipping level is also evaluated for the different number of codes in both, AWGN and frequency flat fading channel.

  • PDF

DEVELOPMENT OF THE MULTI-DIMENSIONAL HYDRAULIC COMPONENT FOR THE BEST ESTIMATE SYSTEM ANALYSIS CODE MARS

  • Bae, Sung-Won;Chung, Bub-Dong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1347-1360
    • /
    • 2009
  • A multi-dimensional component for the thermal-hydraulic system analysis code, MARS, was developed for a more realistic three-dimensional analysis of nuclear systems. A three-dimensional and two-fluid model for a two-phase flow in Cartesian and cylindrical coordinates was employed. The governing equations and physical constitutive relationships were extended from those of a one-dimensional version. The numerical solution method adopted a semi-implicit and finite-difference method based on a staggered-grid mesh and a donor-cell scheme. The relevant length scale was very coarse compared to commercial computational fluid dynamics tools. Thus a simple Prandtl's mixing length turbulence model was applied to interpret the turbulent induced momentum and energy diffusivity. Non drag interfacial forces were not considered as in the general nuclear system codes. Several conceptual cases with analytic solutions were chosen and analyzed to assess the fundamental terms. RPI air-water and UPTF 7 tests were simulated and compared to the experimental data. The simulation results for the RPI air-water two-phase flow experiment showed good agreement with the measured void fraction. The simulation results for the UPTF downcomer test 7 were compared to the experiment data and the results from other multi-dimensional system codes for the ECC delivery flow.

Development and Positioning Accuracy Assessment of Precise Point Positioning Algorithms Based on GLONASS Code-Pseudorange Measurements

  • Kim, Mi-So;Park, Kwan-Dong;Won, Jihye
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.4
    • /
    • pp.155-161
    • /
    • 2014
  • The purpose of this study is to develop precise point positioning (PPP) algorithms based on GLONASS code-pseudorange, verify their performance and present their utility. As the basic correction models of PPP, we applied Inter Frequency Bias (IFB), relativistic effect, satellite antenna phase center offset, and satellite orbit and satellite clock errors, ionospheric errors, and tropospheric errors that must be provided on a real-time basis. The satellite orbit and satellite clock errors provided by Information-Analytical Centre (IAC) are interpolated at each observation epoch by applying the Lagrange polynomial method and linear interpolation method. We applied Global Ionosphere Maps (GIM) provided by International GNSS Service (IGS) for ionospheric errors, and increased the positioning accuracy by applying the true value calculated with GIPSY for tropospheric errors. As a result of testing the developed GLONASS PPP algorithms for four days, the horizontal error was approximately 1.4 ~ 1.5 m and the vertical error was approximately 2.5 ~ 2.8 m, showing that the accuracy is similar to that of GPS PPP.

On the validation of ATHLET 3-D features for the simulation of multidimensional flows in horizontal geometries under single-phase subcooled conditions

  • Diaz-Pescador, E.;Schafer, F.;Kliem, S.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3567-3579
    • /
    • 2022
  • This paper provides an assessment of fluid transport and mixing processes inside the primary circuit of the test facility ROCOM through the numerical simulation of Test 2.1 with the system code ATHLET. The experiment represents an asymmetric injection of cold and non-borated water into the reactor coolant system (RCS) of a pressurized water reactor (PWR) to restore core cooling, an emergency procedure which may subsequently trigger a core re-criticality. The injection takes place at low velocity under single-phase subcooled conditions and presents a major challenge for the simulation in lumped parameter codes, due to multidimensional effects in horizontal piping and vessel arising from density gradients and gravity forces. Aiming at further validating ATHLET 3-D capabilities against horizontal geometries, the experiment conditions are applied to a ROCOM model, which includes a newly developed horizontal pipe object to enhance code prediction inside coolant loops. The obtained results show code strong simulation capabilities to represent multidimensional flows. Enhanced prediction is observed at the vessel inlet compared to traditional 1-D approach, whereas mixing overprediction from the descending denser plume is observed at the upper-half downcomer region, which leads to eventual deviations at the core inlet.

The Analysis of Performance for W-CDMA System using Channel Coding & Phse Hopping 4-Tx Space-Time Code over ITU-R realistic channel model. (ITU-R 실측 채널 모델에서 채널 코딩과 Phase Hopping 4-Tx 시공간 부호를 적용한 W-CDMA 시스템의 성능분석)

  • Park Jeong-Hyun;Kim Kwang-jin;Oh Dong-jin;Kim Cheol-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.75-78
    • /
    • 2004
  • In this paper, we analyze the performance of transmitter and receiver of W-CDMA system using the channel coding and space time code in downlink over ITU-R realistic channel model. We can improve the data rate and the reliability of communications by a channel code, and we can get a diversity gain by using the space time code over fading channels. We also apply the RAKE receiver to improve a performance in multi-path fading channel environment.

  • PDF

On Optimal PN Code Acquisition (최적화된 PN Code Acquisition에 대한 연구)

  • Jang, U-Jin
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.23-25
    • /
    • 1998
  • Many of the currently used PN code acquisition algorithms detect the phase of the incoming PN signal on the basis of ML estimation principle and utilize statistics grounded in taking inner products. By showing that any set of 2n-1 PN sequences arising in SSRG or MSRG (those typically used in IS'95 implementations) configuration constitutes a linearly independent set and that the number of candidate PN sequences has to equal the dimension of the span of the candidate PN sequences, we prove that the lowerbounding computational complexity involved in any PN code acquistion, utilizing (only) inner product computations at each stage of acquisition, corresponds precisely to those, such as double dwell acquistion circuitries, currently used.

  • PDF

Analysis of Propellant Feeding Sub-Systems for Liquid Rocket (SINDA/FLUINT를 활용한 발사체 추진기관 공급계 해석)

  • Cho, Nam-Kyung;Jeong, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-244
    • /
    • 2006
  • The analysis of propellant feeding sub-system is performed using a commercial code SINDA/FLUINT, the comprehensive finite-difference, one-dimensional, lumped parameter tool. With the code, cryogenic helium supply system, liquid oxygen supply system, helium injection cooling system are evaluated. The code gave satisfactory estimation scheme for propulsion system characterized by cryogenic temperature and high pressure, two phase flow. This paper focuses on presenting calculation scheme of propulsion sub-system using one-dimensional code like SINDA/FLUINT.

  • PDF

Application of Hyperbolic Two-fluids Equations to Reactor Safety Code

  • Hogon Lim;Lee, Unchul;Kim, Kyungdoo;Lee, Won-Jae
    • Nuclear Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.45-54
    • /
    • 2003
  • A hyperbolic two-phase, two-fluid equation system developed in the previous work has been implemented in an existing nuclear safety analysis code, MARS. Although the implicit treatment of interfacial pressure force term introduced in momentum equation of the hyperbolic equation system is required to enhance the numerical stability, it is very difficult to implement in the code because it is not possible to maintain the existing numerical solution structure. As an alternative, two-step approach with stabilizer momentum equations has been selected. The results of a linear stability analysis by Von-Neumann method show the equivalent stability improvement with fully-implicit solution method. To illustrate the applicability, the new solution scheme has been implemented into the best-estimate thermal-hydraulic analysis code, MARS. This paper also includes the comparisons of the simulation results for the perturbation propagation and water faucet problems using both two-step method and the original solution scheme.

A Study on the PN code Acquisition for DS/CDMA System over Phas-Error (위상에러를 고려한 DS/CDMA시스템의 PN 부호 획득에 관한 연구)

  • 정남모
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.3
    • /
    • pp.128-134
    • /
    • 2002
  • In this paper, the performance on the PN code acquisition of DS/CDMA system was analyzed using the Nakagami-m probability density function considered fading environment. The equations on detection probability, $P_D$ and false alarm probability, $P_{FA}$, decision variables affecting the PN code acquisition time were derived and proved using simulation in order to analyze the performance. In conclusion, It was necessary increasing the gain of PLL for correcting phase errors and improving the acquisition performance of PN code in apply to the rake receiver.

  • PDF

Development of the Unified Version of COBRA/RELAP5

  • J. J. Jeong;K. S. Ha;B. D. Chung;Lee, W. J.;S. K. Sim
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.591-598
    • /
    • 1997
  • The COBRA/RELAPS code, an integrated version of the COBRA-TF and RELAP5/MOD3 codes, has been developed for the realistic simulations of complicated, multi-dimensional, two-phase, thermal-hydraulic system transients in light water reactors. Recently, KAERA developed an unified version of the COBRA/RELAP5 code, which can run in serial mode on both workstations and personal computers. This paper provides the brief overview of the code integration scheme, the recent code modifications, the developmental assessments, and the future development plan.

  • PDF