• Title/Summary/Keyword: code calibration

Search Result 125, Processing Time 0.027 seconds

An application of MMS in precise inspection for safety and diagnosis of road tunnel (도로터널에서 MMS를 이용한 정밀안전진단 적용 사례)

  • Jinho Choo;Sejun Park;Dong-Seok Kim;Eun-Chul Noh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.2
    • /
    • pp.113-128
    • /
    • 2024
  • Items of road tunnel PISD (Precise Inspection for Safety and Diagnosis) were reviewed and analyzed using newly enhanced MMS (Mobile Mapping System) technology. Possible items with MMS can be visual inspection, survey and non-destructive test, structural analysis, and maintenance plan. The resolution of 3D point cloud decreased when the vehicle speed of MMS is too fast while the calibration error increased when it is too slow. The speed measurement of 50 km/h is determined to be effective in this study. Although image resolution by MMS has a limit to evaluating the width of crack with high precision, it can be used as data to identify the status of facilities in the tunnel and determine whether they meet disaster prevention management code of tunnel. 3D point cloud with MMS can be applicable for matching of cross-section and also possible for the variation of longitudinal survey, which can intuitively check vehicle clearance throughout the road tunnel. Compared with the measurement of current PISD, number of test and location of survey is randomly sampled, the continuous measurement with MMS for environment condition can be effective and meaningful for precise estimation in various analysis.

Optimization of Analytical Methods for Octacosanol in Related Health-functional Foods with GC-MS (GC-MS를 이용한 건강기능식품 중 옥타코사놀 분석법 개발 연구)

  • Lee, Jin Hee;Oh, Mi Hyune;Lee, Kyung Jin;Kim, Yang Sun;Keum, Eun Hee;Park, Ji Eun;Cho, Mee Hyun;Seong, Min Hye;Kim, Sang A;Kim, Mee hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for health-functional foods (dietary food supplements) to establish regulatory standards and specifications in Korea. In this regard, we continue our research on developing analytical methods for the items. Octacosanol is the major component of polycosanol and is a high-molecular-mass primary fatty alcohol, obtained from sugar cane wax. Previous researchers have shown that octacosanol can lower cholesterol and has antiaggregatory properties, cytoprotective uses, and ergogenic properties for human health. Recently, octacosanol products have been actively introduced into the domestic market because of their functional biological activity. We have developed a sensitive and selective test method for octacosanol that the TMS derivatives by means of gas-chromatographic-tandem mass spectrometry (GC-MS). The trimethylsilyl ether derivative of the target analyte showed excellent chromatographic properties. The procedure was validated in the range of $12.5{\sim}200{\mu}g/L$. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.999, and the limits of detection (LOD) and limits of quantitation (LOQ) were $4.5{\mu}g/L$ and $13.8{\mu}g/L$, respectively. The high recoveries (92.5 to 108.8%) and precision (1.8 to 2.4%) obtained are in accordance with the established validation criteria. Our research can provide scientific evidence to amend the octacosanol test method for the Health-Functional Food Code.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Analytical Method Development for Determination of Silymarin by LC-MS/MS for Related Health Functional Foods (LC-MS/MS를 이용한 건강기능식품 중 실리마린 분석법 연구)

  • Oh, Mihyune;Lee, Jin Hee;Kim, Sang-A;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.124-130
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for the use of health functional foods (dietary food supplement), in order to establish regulatory standards and specifications in Korea. In this regard, we continue to pursue and perform our research on the analytical method development for the items being researched and reviewed. In this study, we have developed a sensitive and selective test method that could simultaneously separate and determinate six major bioactive flavonolignans in silymarin, which are based on the use of a liquid chromatographic-tandem mass spectrometry (LC-MS/MS). The standard calibration curves presented a linearity effect with the correlation coefficient ($r^2$) > 0.999. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of $0.3{\sim}9.0{\mu}g/L$ and $0.8{\sim}27.3{\mu}g/L$, respectively. The recovery results ranged between 96.2~98.6% at 3 different concentration levels, and its relative standard deviations (RSDs) were less than 5% as noted in this study. The proposed analytical method was characterized with a noted high resolution of the individual silymarin constituents, and the assay was fully validated as well. Our research can provide a significant scientific evidence that can be useful to amend the silymarin test method for the Health Functional Food Code.

Monitoring and Risk Assessment of Pesticide Residues in School Foodservice Agricultural Products in Gwangju Metropolitan Area (광주광역시 학교급식 농산물의 잔류농약 모니터링 및 위해평가)

  • Kim, Jinhee;Lee, Davin;Lee, Mingyou;Ryu, Keunyoung;Kim, Taesun;Gang, Gyungri;Seo, Kyewon;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2019
  • This study was performed to monitor the residual pesticides in agricultural products used in school foodservice in the Gwangju metropolitan area. Risk assessment was also carried out based on the amount of agricultural products consumed. A total of 320 agricultural products supplied to schools in Gwangju were analyzed from 2015 to 2017. The pre-treatment and residual pesticide analysis of these products was conducted in accordance with the second method for multi-residue analysis of pesticides in the Korean food code. The hazard index was calculated by dividing the estimated daily intake (EDI) of pesticides by the acceptable daily intake (ADI). The linearity correlation coefficient for the calibration curve was 0.9923 to 1.0000, LOD 0.004 to 0.019 mg/kg, LOQ 0.012 to 0.057 mg/kg, and recovery was 79.1 to 100.2%. Residual pesticides were detected in 18 (5.6%) of 320 agricultural products used for school foodservice, and one sample of sweet potato stem (0.3%) exceeded the maximum residual limit (MRL). The detection frequency for chili peppers and bell peppers was higher than that for other agricultural products. The frequently-detected pesticides were boscalid and acetamiprid. These results showed that residual pesticide management is needed for chili pepper, bell pepper and sweet potato stem among agricultural products supplied to schools. The hazard index of bifenthrin in sweet potato stem showed the highest (64.18%), and the other pesticides were 0.03-8.23%. These results indicated that agricultural products supplied to schools in Gwangju were safe for consumption. To minimize the intake of residual pesticides, it is necessary to not only thoroughly wash agricultural products but to also ensure the expanded supply of products that are pesticide-free.