• 제목/요약/키워드: coated tube

검색결과 139건 처리시간 0.024초

TiN코팅한 지르칼로이-4튜브의 프레팅 특성 (Fretting Characteristics of TiN Coated Zircaloy-4 Tube)

  • 성지현;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제31회 춘계학술대회
    • /
    • pp.269-275
    • /
    • 2000
  • The fretting wear characteristics of TiN coated Zircaloy-4 tube were investigated experimentally The fretting wear experiment was performed using TiN coated Zircaloy-4 tube as the fuel rod cladding material and uncoated Zircaloy-4 tube as one of grids. TiN coating is probably one of the most frequently and successfully used PVD coatings for the mitigation of fretting wear. In this study, TiN coating by PVD was employed for improvement of Zircaloy-4 tube fretting characteristics. The fretting tester was designed and manufactured for this experiment. TiN coated Zircaloy-4 tube was used as the moving specimen, uncoated ZircaBoy-4 tube as the stationary one. The number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. The results of this research showed that the wear volume of TiN coated Zircaloy-4 tube increased as number of cycles, normal load and slip amplitude increase but the quantity of volume was lower than the case of uncoated Zircaloy-4 tube pairs.

  • PDF

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

Tube의 형상 및 표면특성에 의한 Shell-and-Tube 열교환기의 열전달 성능 (The Performance in Shell-and-Tube Heat Exchangers with Configuration and Surface Characteristics of Tube)

  • 김성일;박기호;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2316-2321
    • /
    • 2008
  • This paper presents an improved performance of heat transfer for shell-and-tube and thermal analysis based on the Bell-Delaware method for single tube. Heat transfer has been compared for a smooth tube, helical tube and surface-coated tube. In general, the results showed that properly designed helical tube and surface-coated tube offer a significant improvement in heat transfer. The numerical results derived from the Bell-Delaware method for the shell-side heat transfer coefficient were verified with experimental results. The thermal analysis aids significantly in the solution of the design problem.

  • PDF

Coated tube를 사용한 CA19-9 측정용 IRMA 시약의 평가 (Evaluation of Coated Tube CA19-9 IRMA kit)

  • 이현주;장현영;신선영;김희선;김태훈;이호영
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.208-211
    • /
    • 2010
  • 현재 본원은 TFB사의 CA19-9 항체가 bead에 코팅되어있는 CA19-9 IRMA 시약을 사용하고있다. 이번에 TFB사에서 새로 개발된 CA19-9 항체가 polystyrene test tube에 코팅된 CA 19-9 IRMA 시약이 기존 TFB사의 bead를 사용하는 시약을 대체하여 사용할 수 있는지 시약의 성능을 평가하였다. 본원과 서울대학교병원 환자 56명의 검체를 대상으로 하여 TFB사의 기존 bead 방법을 사용한 시약과 새로 개발된 coated tube를 사용한 시약을 비교하여 상관계수와 회귀식을 구하고 coated tube를 사용한 시약의 정밀도, 회수율, 직선성, 민감도, Hook effect 를 확인하였다. 저, 중, 고역가 검체의 검사내 정밀도는 4.1%, 4.0%, 4.2%이고 검사간 정밀도는 7.6%, 4.3%, 7.8%이며 회수율은 모두 $100{\pm}10%$이다. 직선성은 우수하였고 분석적민감도는 0.3U/mL이었으며 9,020,000 U/mL 농도에서는 Hook effect가 나타나지 않았다. 또한 TFB사의 기존 bead를 사용한 방법과 비교하여 상관관계를 분석한 결과, y=0.9185x-0.953, 상관계수 $R^2$=0.9779이었다. 이번 연구를 통해 본원은 TFB사에서 새로 개발된 coated tube CA19-9 IRMA 시약이 검사 시간과 검사 과정에서 간편화되고 검사시 자동화기기를 사용할 수 있으며 기존 bead를 사용한 시약에 대체하여 사용할 수 있다고 판단하였다.

  • PDF

연료극 지지체식 원통형 고체산화물 연료전지의 제조 및 특성연구 (Fabrication and Characteristics of Anode-Supported Tubular Solid Oxide Fuel Cell)

  • 김응용;송락현;신동열;임영언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1547-1549
    • /
    • 1999
  • As a preliminary experiment for the development of anode-supported tubular cell with proper porosity, we have investigated the anode substrate and the electrolyte-coated anode tube. The anode substrate was manufactured as a function of carbon content in the range of 20 to 50 vol.%. As the caron content increased, the porosity of the anode substrate increased slightly and the carbon content with proper porosity was obtained at 30 vol.%. The anode tube was fabricated by extrusion process and the electrolyte layer was coated on the anode tube by slurry dipping process. The anode-supported tube was cofired successfully. Their sintered property and microstructure were examined and the porosity of the anode tube was 35%. From the gas permeation test, the anode tube was found to be porous enough for gas supply. On the other hand, the anode-supported tube with electrolyte layer indicated a very low gas permeation rate. This means that the coated electrolyte was dense. Based upon these experimental results. we will fabricate and test the anode-supported tubular cell.

  • PDF

TiAIN 코팅한 핵연료봉 피복재의 프레팅 마멸 평가 (Fretting Wear Evaluation of TiAIN Coated Nuclear Fuel Rod Cladding Materials)

  • 김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.88-95
    • /
    • 2002
  • Fretting of fuel rod cladding material, Zircaloy-4 Tube, in PWR nuclear power plants must be reduced and avoided. Nowadays the introduction of surface treatments or coatings is expected to bean ideal solution to fretting damage since fretting is closely related to wear, corrosion and fatigue. Therefore, in this study the fretting wear experiment was peformed using TiAIN coated Zircaloy-4 tube as the fuel rod cladding and uncoated Zircaioy-4 tube as one of grids, especially concentrating on the sliding component. Fretting wear resistance of TiAIN coated Zircaloy-4 tubes was improved compared with that of TiN coated tubes and uncoated tubes and the fretting wear mechanisms were delamination and plastic flow following by brittle fracture at lower slip amplitude but severe oxidation and spallation of oxidative layer at higher slip amplitude.

  • PDF

High-temperature oxidation behaviors of ZrSi2 and its coating on the surface of Zircaloy-4 tube by laser 3D printing

  • Kim, Jae Joon;Kim, Hyun Gil;Ryu, Ho Jin
    • Nuclear Engineering and Technology
    • /
    • 제52권9호
    • /
    • pp.2054-2063
    • /
    • 2020
  • The high-temperature oxidation behavior of ZrSi2 used as a coating material for nuclear fuel cladding was investigated for developing accident-tolerant fuel cladding of light water reactors. Bulk ZrSi2 samples were prepared by spark plasma sintering. In situ X-ray diffraction was conducted in air at 900, 1000, and 1100 ℃ for 20 h. The microstructures of the samples before and after oxidation were examined by scanning electron microscopy and transmission electron microscopy. The results showed that the oxide layer of zirconium silicide exhibited a layer-by-layer structure of crystalline ZrO2 and amorphous SiO2, and the high-temperature oxidation resistance was superior to that of Zircaloy-4 owing to the SiO2 layer formed. ZrSi2 was coated on the Zircaloy-4 tube surface using laser 3D printing, and the coated tube was oxidized for 2000 s at 1200 ℃ under a vapor/argon mixture atmosphere. The outer surface of the coated tube was hardly oxidized (10-30 ㎛), while the inner surface of the uncoated tube was significantly oxidized to approximately 300 ㎛.

습식법에 의한 고체산화물 연료전지용 연료극 지지체관의 제조 및 특성 연구 (Fabrication and Characteristics of Anode-Supported Tube for Solid Oxide Fuel Cell)

  • 김응용;송락현;임영언
    • 한국재료학회지
    • /
    • 제10권10호
    • /
    • pp.659-664
    • /
    • 2000
  • 연료극 지지체식 원통형 고체산화물 연료전지를 개방하기 위해 연료극 지지체와 전해질이 코팅된 연료극 원통관의 제조 및 그것의 특성에 대해 연구하였다- 연료극 지지체는 20-50vol.%의 탄소함량에 따라 만들어졌으며, 탄소량이 증가함에 따라 연 료극 지지체의 기공율도 점차 증가하였으며, 적절한 기공율을 가지기 위한 최적 탄소량은 30vol.%임을 확인하였다. 연료극 지지체 관은 압출법으로 제작하였으며, 전해질은 슬러리 코팅법으로 원통판의 바깥쪽에 코팅하였고, $1400^{\circ}C$에서 공소결을 성공적으로 실시하였다. 소결후 물리척특성과 미세구조를 조사하였으며, 연료극 지지체관의 기공율은 35%이었고 연료전지의 요구조건을 만족하였다. 기체투과율 시험을 통하여, 연료극 지지체관 자체는 충분히 다공성을 나타내었으나, 전해질층을 코팅한 경우에는 매우 낮은 기체부과율을 나타냄을 확인하였다. 이것은 코팅된 전해질층이 매우 치밀하다는 것을 의미하며, 본 연구를 통해서 연료극 지지체식 원통형 고체산화물 연료전지가 제조될 수 있음을 확인하였다.

  • PDF

EXPERIMENTAL INVESTIGATION OF FRETTING BEHAVIOR OF TiAlN COATED NUCLEAR FUEL ROD CLADDING MATERIALS

  • Kim, T.H.;Kim, S.S.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.185-186
    • /
    • 2002
  • Fretting of fuel rod cladding material, Zircaloy-4 tube, in PWR nuclear power plants must be reduced and avoided. Nowadays the introduction of surface treatments or coatings is expected to be an ideal solution to fretting damage since fretting is closely related to wear. corrosion and fatigue. Therefore. in this study the fretting wear experiment was performed using TiAlN coated Zircaloy-4 tube as the fuel rod cladding and uncoated Zircaloy-4 as on of grids, especially concentrating on the sliding component. Fretting wear resistance of TiAlN coated Zircaloy-4 tubes was improved compared with that of TiN coated tubes and uncoated tubes and fretting wear mechanisms were brittle fracture and plastic flow at lower slip amplitude but severe oxidation and spallation of oxidative layer at higher ship amplitude.

  • PDF

석영관 광촉매 반응기를 이용한 Rhodamine B의 색도 제거 (Decolorization of Rhodamine B Using Quartz Tube Photocatalytic Reactor)

  • 박영식
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.358-365
    • /
    • 2004
  • The photocatalytic oxidation of Rhodamine B(RhB) was studied using photocatalytic reactor filled with module of quartz tube. Module of quartz tube consisted of small quartz tube (inner diameter, 1.5 mm; outer diameter, 3 mm) bundle coated with powder $TiO_2$ and uncoated large quartz tube (inner diameter, 20 mm; outer diameter, 22 mm). Two 30 W germicidal lamp was used as the light source and the reactor volume was 0.5 l. The effects of parameters such as the coating materials and numbers, initial concentration, $H_{2}O_2$ dose and metal deposition (Ag, Pt and Fe) and simultaneous application of $H_{2}O_2$ and metal deposition. The results showed that the initial reaction constant of quartz module coated with powder $TiO_2$ was higher 1.4 time than that of the $TiO_2$ sol and optimum coating number is twice. In order to increase reaction rate, simultaneous application of photocatalytic and photo-fenton reaction using Fe coating and dose $H_{2}O_2$ dose increased reaction rate largely.