• Title/Summary/Keyword: coated rate

Search Result 1,012, Processing Time 0.03 seconds

Electrochemical Characteristics of Ultra Battery Anode Material using the Nano Pb/AC for ISG (나노 납/활성탄을 사용한 ISG용 울트라 전지 음극소재의 전기화학적 특성)

  • Hwang, Jin Ung;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.593-599
    • /
    • 2017
  • In order to enhance ultra battery performances, the electrochemical characteristics of nano Pb/AC anode composite was investigated. Through nano Pb adsorption onto activated carbon, nano Pb/AC was synthesized and it was washed under vacuum process. The prepared anode materials was analysed by SEM, BET and EDS. The specific surface area and average pore size of nano Pb/AC composite were $1740m^2/g$ and 1.95 nm, respectively. The negative electrode of ultra battery was prepared by nano Pb/AC dip coating on lead plate. The electrochemical performances of ultra battery were studied using $PbO_2$ (the positive electrode) and prepared nano Pb/AC composite (the negative electrode) pair. Also the electrochemical behaviors of ultra battery were investigated by charge/discharge, cyclic voltammetry, impedance and rate capability tests in 5 M $H_2SO_4$ electrolyte. The initial capacity and cycling performance of the present nano Pb/AC ultra battery were improved with respect to the lead battery and the AC-coated lead battery. These experimental results indicate that the proper addition of nano Pb/AC into the negative electrode can improve the discharge capacity and the long term cycle stability and remarkably suppress the hydrogen evolution reaction on the negative electrode.

Effects of Slow-release Nitrogen Fertilizers on Yield and Nitrogen Uptake of IR667 (IR667의 수량(收量) 및 질소흡수(窒素吸收)에 미치는 완효성 질소비종별(窒素肥種別) 효과)

  • Kwon, Hang Gwang;Park, Hoon;Park, Young Sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.4
    • /
    • pp.213-219
    • /
    • 1973
  • Effects of three slow-release nitrogen fertilizers (Sulfur-coated urea, (SCU) Jin Hae Chemical Co. Korea(JHC); Tennessee Valley Authority. U.S.A(TVA); METAP, Japan) on the yield and nitrogen uptake of IR667 (Suwon 213) were investigated comparing with urea split application under the field condition with early and usual saeson cultivation. 1. SCU(JHC) was not superior than urea split application in yield and nitrogen nutrition due to early release of nitrogen. 2. SCU(TVA) outyielded urea split by 10% showed always highest nitrogen content in straw and most balanced relative cumulative curve of nitrogen uptake or dry matter yield. 3. At ear formation stage SCU(TVA) showed specially high nitrogen content which was highly correlated with number of grain per $m^2$ of field. 4. Only SCU(TVA) showed one peak curve of nitrogen uptake rate at ear formation stage while others showed two peak pattern. 5. nitrogen fertilizer recovery of slow-release fertilizers was higher than urea split in early season cultivation and SCU (TVA) (46.0) was higher but SCU(JHC) (38.9) was similar in compare with urea split(37.1) in usual season cultivation. 6. Most promising slow-release nitrogen to match plant requirement seems to be one mixed of various slow-release fertilizers having different release pattern.

  • PDF

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

Boron Doping Method Using Fiber Laser Annealing of Uniformly Deposited Amorphous Silicon Layer for IBC Solar Cells (IBC형 태양전지를 위한 균일하게 증착된 비정질 실리콘 층의 광섬유 레이저를 이용한 붕소 도핑 방법)

  • Kim, Sung-Chul;Yoon, Ki-Chan;Kyung, Do-Hyun;Lee, Young-Seok;Kwon, Tae-Young;Jung, Woo-Won;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.456-456
    • /
    • 2009
  • Boron doping on an n-type Si wafer is requisite process for IBC (Interdigitated Back Contact) solar cells. Fiber laser annealing is one of boron doping methods. For the boron doping, uniformly coated or deposited film is highly required. Plasma enhanced chemical vapor deposition (PECVD) method provides a uniform dopant film or layer which can facilitate doping. Because amorphous silicon layer absorption range for the wavelength of fiber laser does not match well for the direct annealing. In this study, to enhance thermal affection on the existing p-a-Si:H layer, a ${\mu}c$-Si:H intrinsic layer was deposited on the p-a-Si:H layer additionally by PECVD. To improve heat transfer rate to the amorphous silicon layer, and as heating both sides and protecting boron eliminating from the amorphous silicon layer. For p-a-Si:H layer with the ratio of $SiH_4$ : $B_2H_6$ : $H_2$ = 30 : 30 : 120, at $200^{\circ}C$, 50 W, 0.2 Torr for 30 minutes, and for ${\mu}c$-Si:H intrinsic layer, $SiH_4$ : $H_2$ = 10 : 300, at $200^{\circ}C$, 30 W, 0.5 Torr for 60 minutes, 2 cm $\times$ 2 cm size wafers were used. In consequence of comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 20 ~ 27 % of power, 150 ~ 160 kHz, 20 ~ 50 mm/s of marking speed, and $10\;{\sim}\;50 {\mu}m$ spacing with continuous wave mode of scanner lens showed the correlation between lifetime and sheet resistance as $100\;{\Omega}/sq$ and $11.8\;{\mu}s$ vs. $17\;{\Omega}/sq$ and $8.2\;{\mu}s$. Comparing to the singly deposited p-a-Si:H layer case, the additional ${\mu}c$-Si:H layer for doping resulted in no trade-offs, but showed slight improvement of both lifetime and sheet resistance, however sheet resistance might be confined by the additional intrinsic layer. This might come from the ineffective crystallization of amorphous silicon layer. For the additional layer case, lifetime and sheet resistance were measured as $84.8\;{\Omega}/sq$ and $11.09\;{\mu}s$ vs. $79.8\;{\Omega}/sq$ and $11.93\;{\mu}s$. The co-existence of $n^+$layeronthesamesurfaceandeliminating the laser damage should be taken into account for an IBC solar cell structure. Heavily doped uniform boron layer by fiber laser brings not only basic and essential conditions for the beginning step of IBC solar cell fabrication processes, but also the controllable doping concentration and depth that can be established according to the deposition conditions of layers.

  • PDF

Effect of the processing variables on the formation of $Pb(Sc_{1/2}Nb_{1/2})O_3$ thin layers ($Pb(Sc_{1/2}Nb_{1/2})O_3$ 박막 형성에 미치는 공정변수의 영향)

  • Park, Kyung-Bong;Kwon, Seung-Hyeop;Kim, Tae-Huei
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.70-74
    • /
    • 2009
  • Effect of the processing variables on the formation of $Pb(Sc_{1/2}Nb_{1/2})O_3$(hereafter PSN) thin layers prepared on Pt(111)/Ti/$SiO_2$/Si substrates using the sol-gel and the spin coating method has been studied. After each deposition, the coated films were heated at $370^{\circ}C$ for 5 min. Then they were finally sintered at temperature range of $600{\sim}700^{\circ}C$ by RTA(rapid thermal annealing). The final multilayered films showed a (111) preferred orientation. On a while, the layer-by-layer crystallization of multilayered amorphous thin films without the intermediate heating exhibited a (100) preferred orientation. In case of heat treatment in the tube furnace with the heating rate of $4^{\circ}C/min$, (100) and (111) oriented thin layers were formed simultaneously. The microstructure of the deposited films were dense and crack-free with thickness of 300nm, irrespective of the processing variables.

Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis (모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향)

  • Lee, Kwang-Woo;Jeon, Ji-Young;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • A rapid analytical method based on capillary electrophoresis is described for the determination of trace anions in high-purity chemicals which is used to prevent corrosion demage in nuclear power plants. Separations are carried out at 20kV using trimethylsilane-coated fused-silica capillary ($70cm{\times}50$ or $75{\mu}m$ i.d.) with the electrolyte of 5mM Chromate(pH=8). Detection was achieved using on-column indirect photometry at 254nm. The simultaneous analysis of inorganic anions, chloride, nitrate, sulfate, azide and phosphate was performed using methods of hydrodynamic(>1ppm) and / or electrokinetic(<1ppm) injection. The results of studies on the coexisting anions on analyte ions shows that peak responses of analyte in hydrodynamic injection is constant without effect of coexisting anions, but those of analysis in electrokinetic injection is strongly dependant upon the kind of coexisting anions and its ionic mobility. The analyte enrichment rate, hence peak response, is positive relationship with the resistance of the sample solution. Thus, appropriate measures, such as standard addition or internal standard technique, must be used to account for differences in conductance of standard and sample solutions.

  • PDF

Detection of Astrovirus Infection from Hospitalized Young Children Feces by Reverse Transcription-Polymerase Chain Reaction (중증 위장관염 소아의 대변검체에서 역전사-중합효소 연쇄반응을 이용한 Astrovirus 검출)

  • Park, Hae-Kyung;Woo, So-Youn;Seoh, Ju-Young;Chong, Young-Hae;Seo, Jeong-Wan
    • The Journal of the Korean Society for Microbiology
    • /
    • v.34 no.5
    • /
    • pp.453-459
    • /
    • 1999
  • Astrovirus is frequently associated with diarrhea in children. It can not be readily isolated by cell culture, and an electronmicroscope is usually used for detection of this agent. Recently in 1995 a combined method of reverse transcription-polymerase chain reaction (RT-PCR) was designed for easier detection of astrovirus, which is based on the conserved sequence in 3'-end of genomes of the 7 known serotypes of human astrovirus. As of yet there has not been any report of astrovirus data in Korea using the RT-PCR methods. The purpose of this study was to detect astrovirus incidence, severity of symptoms, seasonal variation and co infection rate with rotavirus in Korean children inpatients with diarrhea. Fecal specimens from 61 young children hospitalized with gasteroenteritis Korea from Jan. 1996 through Mar. 1997. They were examined for astroviurs infection by RT-PCR method. Results are as follows:1. Astrovirus was detected at 9.8% (6/61) from fecal specimens of children with severe diarrhea by EIA using monoclonal antibody coated plates. 2. Astorvirus was detected at 29.5% (18/61) from fecal specimens of children with severe diarrhea by RT-PCR. 3. The age of the 18 children affected by astrovirus ranged from 2 monthes to 7 years with mean of 3.0 years. 4. Mean hospital stay of the 18 children was 6.1 days. 5. Five (27.8%) astrovirus RT-PCR positive strains were confirmed in November and in December, respectively out of 18 specimens in total. 6. Astrovirus coinfection with rotavirus type G1 was confirmed in 15/16 specimens (93.8%), and with type G2 was in 1/16 specimens (6.3%).

  • PDF

Effects of Improvement of Soil Physical Property & Diagnostic Fertilization on Yield and N-Use Efficiency in Puddled-Soil Drill Seeding of Rice (토양물리성개선(土壤物理性改善) 및 진단시비(診斷施肥)가 무논골뿌림직파(直播) 벼의 질소이용효율(窒素利用效率)과 수량(收量)에 미치는 영향(影響))

  • Kang, Seung-Weon;Yoo, Chul-Hyun;Han, Sang-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.254-260
    • /
    • 1999
  • This experiment was carried out to evaluate the effect of improvement of soil physical property such as deep plowing and chiseling and diagnostic application of N, P, K fetilizers. Latex Coated Urea(LCU), compost, sillicate for increasing yielding and enchancing N-use efficiency in puddled-soil drill seeding of Rice. The soil physical properties, such as bulk density, hardness and porosity were increased by deep plowing and chiseling, as well as chemical propeties were highly enhanced soil productivity due to increase the content of organic matter, available $P_2O_5$ and K as compare with control. The amount of $NH_4-N$ in soil was highly increased by diagnostic fertilization and chiseling, while recovery rate of V fertilizer was the highest at LCU 80% applied with chiseling. The rice yield increased by 23% under the diagnositic application of LCU 80% applied base with chiseling.

  • PDF

Chromaticity(b*), Sheet Resistance and Transmittance of SiO2-ITO Thin Films Deposited on PET Film by Using Roll-to-Roll Sputter System (롤투롤시스템을 이용하여 PET 필름위에 제조된 SiO2-ITO 박막의 색도(b*), 면저항과 투과도 연구)

  • Park, Mi-Young;Kang, Bo-Gab;Kim, Jung-Soo;Kim, Hye-Young;Kim, Hu-Sik;Lim, Woo-Taik;Choi, Sik-Young
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.255-262
    • /
    • 2011
  • This paper has relatively high technical standard and experimental skill. The fabrication of TCO film with high transparency, low resistance and low chromaticity require exact control of several competing factors. This paper has resolved these problems reasonably well, thus recommended for publication. Indium tin oxide(ITO) thin films were by D.C. magnetron roll-to-roll sputter system utilizing ITO and $SiO_2$ targets of ITO and $SiO_2$. In this experiment, the effect of D.C. power, winding speed, and oxygen flow rate on electrical and optical properties of ITO thin films were investigated from the view point of sheet resistance, transmittance, and chromaticity($b^*$). The deposition of $SiO_2$ was performed with RF power of 400W, Ar gas of 50 sccm and the deposition of ITO, DC power of 600W, Ar gas of 50 sccm, $O^2$ gas of 0.2 sccm, and winding speed of 0.56m/min. High quality ITO thin films without $SiO_2$ layer had chromaticity of 2.87, sheet resistivity of 400 ohm/square, and transmittance of 88% and $SiO_2$-doped ITO Thin film with chromaticity of 2.01, sheet resistivity of 709 ohm/square, and transmittance of more than 90% were obtained. As a result, $SiO_2$ was coated on PET before deposition of ITO, their chromaticity($b^*$) and transmittance were better than previous results of ITO films. These results show that coating of $SiO_2$ induced arising chromaticity($b^*$) and transmittance. If the thickness of $SiO_2$ is controlled, sheet resistance value of ITO film will be expected to be better for touch screen. A four point probe and spectrophotometer are used to investigate the properties of ITO thin films.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF