• Title/Summary/Keyword: coagulation factor

Search Result 146, Processing Time 0.037 seconds

A Case of Heel Reconstruction with a Reverse Sural Artery Flap in a Hemophilia B Patient

  • Lee, Byung-Kwon;Shim, Jeong-Su
    • Archives of Plastic Surgery
    • /
    • v.39 no.2
    • /
    • pp.150-153
    • /
    • 2012
  • Hemophilia B is a rare blood coagulation disorder. Complications such as bleeding and hematoma can cause necrosis of flaps, wound disruption, and the disturbance of wound healing. In particular, guidelines for flap operations in hemophilia B patients have still not been defined, and case reports are rare. We reconstructed the heel of a 41-year-old male hemophilia B patient using a reverse sural artery flap operation. The patient presented with mild hemophilia, having 27% of the normal value of coagulation factor IX. Coagulation and the changing value of the coagulation factor were regularly measured, and 70% of the normal value of coagulation factor IX was maintained through the injection of recombinant coagulation factors and antihemorrhagics. Hematoma developed twice (postoperative day [POD] 5 and POD 7) and in each case the hematoma was removed. Injections of recombinant coagulation factors and antihemorrhagics were continuously administered until postoperative week 2. When the coagulation factors were within normal ranges. In this article, a hemophilia B patient underwent reverse sural artery flap surgery and the healing progress was analyzed. We conclude that higher than baseline levels of coagulation factors are needed for successful healing in reverse sural artery flap surgery.

Effects of Tenebrio molitor larvae oil on liver damage and blood clot formation in obesity

  • Bo Mi Park;Bong Joo Lee
    • Korean Journal of Veterinary Service
    • /
    • v.46 no.2
    • /
    • pp.107-113
    • /
    • 2023
  • Tenebrio molitor, rich in protein, is used as an alternative protein source. Many studies have evaluated Tenebrio molitor larvae (TML) for anti-obesity effects, fatty liver relief, antithrombosis, and antioxidant effects. In this study, we prepared an experimental diet by adding Tenebrio molitor larvae oil (TMLO) to feed and administered it to adult male ICR mice for six weeks. The study assessed the weight gain of mice, prothrombin time (PT), activated partial thromboplastin time (aPTT), blood coagulation time, and the activities of coagulation factor VII and coagulation factor XII. The weight gain of mice was suppressed in the groups fed with TMLO, indicating a potential anti-obesity effect. The blood coagulation time was delayed in the TMLO-fed groups, as evidenced by amplified PT and aPTT values. Furthermore, the activities of coagulation factor VII and coagulation factor XII were diminished in the TMLO-treated groups, indicating a potential thrombosis relieving effect. The concentrations of thromboxane B2 and serotonin declined in the TMLO-fed groups, signifying potential blood circulation effects. Finally, blood triglyceride and LDL-cholesterol concentrations were reduced in the TMLO-fed groups. In summary, TMLO supplementation may have an inhibitory effect on liver damage and blood clot formation caused by obesity.

Introduction to Coagulation System (혈액응고 기전에 대한 고찰)

  • Lyu, Chuhl-Joo
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Coagulation involves the regulated sequence of proteolytic activation of a series of proteins to achieve appropriate and timely hemostasis in an injured vessel. In the non-pathological state, the inciting event involves exposure of circulating factor VIIa to extravascularly expressed tissue factor, which brings into motion the series of steps which results in cell based model of coagulation. In the new concepts of coagulation system, initiation, amplification and propagation steps are involved to converse of fibrinogen to fibrin. The precisely synchronized cascade of events is counter-balanced by a system of anticoagulant mechanisms. Developmental hemostasis refers to the age-related changes in the coagulation system that are most marked during neonate and childhood. An understanding of these changes in crucial to the accurate diagnosis of hemostatic abnormalities in neonate and children. This review aims to elucidate the main events within the coagulation cascade as it is currently understood to operate in vivo, and also a short review of the anticoagulants as they relate to this model. Also this paper describes the common pitfalls observed in the clinical data related to the coagulation system in neonate to children.

Characterization of Binding Mode for Human Coagulation Factor XI (FXI) Inhibitors

  • Cho, Jae Eun;Kim, Jun Tae;Jung, Seo Hee;Kang, Nam Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1212-1220
    • /
    • 2013
  • The human coagulation factor XI (FXI) is a serine protease that plays a significant role in blocking of the blood coagulation cascade as an attractive antithrombotic target. Selective inhibition of FXIa (an activated form of factor XI) disrupts the intrinsic coagulation pathway without affecting the extrinsic pathway or other coagulation factors such as FXa, FIIa, FVIIa. Furthermore, targeting the FXIa might significantly reduce the bleeding side effects and improve the safety index. This paper reports on a docking-based three dimensional quantitative structure activity relationship (3D-QSAR) study of the potent FXIa inhibitors, the chloro-phenyl tetrazole scaffold series, using comparative molecular field analysis (CoMFA) and comparative molecular similarity analysis (CoMSIA) methods. Due to the characterization of FXIa binding site, we classified the alignment of the known FXIa inhibitors into two groups according to the docked pose: S1-S2-S4 and S1-S1'-S2'. Consequently, highly predictive 3D-QSAR models of our result will provide insight for designing new potent FXIa inhibitors.

Genotype Distribution of the Mutations in the Coagulation Factor V Gene in the Korean Population: Absence of Its Association with Coronary Artery Disease

  • Hong, Seung-Ho
    • Animal cells and systems
    • /
    • v.7 no.3
    • /
    • pp.255-259
    • /
    • 2003
  • Mutations in the factor Ⅴ gene are major risk markers for venous thrombosis. Several factors for blood coagulation have been related with cardiovascular disease. Ⅰ investigated genotype distribution for three mutations (G1691 A, A2379G and G2391 A) of the factor Ⅴ gene in the Korean population. Genotype frequencies were examined by polymerase chain reaction in 135 patients with coronary artery disease (CAD) and 116 healthy subjects. For the G1691A mutation (factor Ⅴ

A Case of Hemophilia A Diagnosed in a Premature Infant (미숙아에서 진단된 혈우병 A 1례)

  • Oh, Ki-Won;Lee, Kyung-Yeon;Kim, Ja-Hyeong;Rhee, Kang-Won;Jeong, Jin-Young;Park, Sang-Kyu
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.132-135
    • /
    • 2010
  • Although the majority of abnormal bleeding during the neonatal period results from acquired coagulation disorders, inherited coagulation disorders can also manifest at this time. Hemophilia is the most common of inherited coagulation disorder. Although 40-70% of cases with hemophilia are diagnosed in the neonatal period, few cases have been reported in premature infants. We report a case of a premature infant born at 31 weeks of gestation, diagnosed with hemophilia A by blood coagulation test, coagulation factor assay and study of the F8 gene. The baby was treated with recombinant factor VIII (Recombinate$^{(R)}$, USA) because of repeated seizures and intramuscular hematoma.

Improving Coagulation Performance with pH Preadjustment in Drinking Water Treatment (정수처리에서 pH 저감에 의한 응집효율향상에 관한 연구)

  • Lee, Hwan;Lee, Cheol-Hyo;Jung, Chang-Gue;Lee, Yoon-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2003
  • This paper reports on a pilot scale comparison of PACS coagulation with and without pH preadjustment. The pH of the water was adjusted with carbon dioxide and sulfuric acid. Process performance was assessed on the basis of total organic carbon(TOC), UV absorbance, turbidity and disinfection by-product(DBP) precursors. Coagulation pH appeared to be a determining factor for maximum NOM removal. The optimum coagulation pH in order to decrease TOC and turbidity were pH 7. Preadjustment of pH 7 increased TOC removal to as much as 43, 47 percent with sulfuric acid and carbon dioxide. Moreover, coagulation at pH 7 caused a reduction in UV$_{254}$, THMFP and HAAFP compared to the baseline coagulation. For preadjustment of pH 7 with carbon dioxide, the percentage of TOC, UV$_{254}$, THMFP and HAAFP shows the reduction rate of 3.8, 0.5, 4.8, 9.4% comparing to the coagulation rendition using sulfuric acid. Acid addition to depress pH during coagulation decrease Langelier Saturation Index(LSI), potentially causing increase corrosion in water distribution systems. LSI for carbon dioxide and sulfuric acid at pH 6 was -2.3, -3.3. Therefore, carbon dioxide was more effective at controlling corrosion than sulfuric acid.

Coagulation Control of High Turbid Water Samples Using a Streaming Current Control System (유동흐름 전류계를 이용한 정수장 고탁도 유입수 응집 제어 방법에 대한 연구)

  • Nam, Seung-Woo;Jo, Byung-Il;Kim, Won-Kyong;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.128-135
    • /
    • 2012
  • Objectives: This study was aimed at determining the optimum coagulation dosage in a high turbid kaolin water sample using streaming current detection (SCD) as an alternative to the jar test. Methods: SCD is able to optimize coagulant dosing by titration of negatively charged particles. Kaolin particles were used to mimic highly turbid water ranging from 50 to 600 NTU, and polyaluminum chloride (PAC, 17%) was applied as a titrant and coagulant. The coagulation consisted of rapid stirring (5 min at 140 rpm), reduced stirring (20 min at 70 rpm), and settling (60 min). To confirm the coagulation effect, a jar test was also compared with the SCD titration results. Results: SCD titration of kaolin water samples showed that the dose of PAC increased as the pH rose. However, supernatant turbidity less than 1 NTU after coagulation was not achieved for high turbid water by SCD titration. Instead, a conversion factor was used to calculate the optimum PAC dosage for high turbid water by correlating a jar test result with that from an SCD titration. Using this approach, we were able to successfully achieve less than 1 NTU in treated water. Conclusions: For high turbid water influent in a water treatment plant, particularly during summer, the application of SCD control by applying a conversion factor can be more useful than a jar test due to the rapid calculation of coagulation dosage. Also, the interpolation of converted PAC dose could successfully achieve turbidity in the treated water of less than 1 NTU. This result indicates that an SCD system can be effectively used in a water treatment plant even for high turbid water during the rainy season.

Analysis of Coagulation Factor Activity of Normal Adults with APTT Limit Range (APTT에서 경계치에 속한 정상 성인의 혈액응고인자 활성도 분석)

  • Kwon, Eui-Hoon;Koo, Bon-Kyung;Bang, Sung-Hwan;Kim, Hee-Jin;Cho, Young-Kuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.237-242
    • /
    • 2015
  • The coagulation factor activity compared two groups of the lower 10% (29.1~30.9 sec) and the upper 10% (38.0~41.9 sec) of the normal reference range of aPTT. The aim of this study was to investigate the influence of sex, age, and ABO blood type on coagulation factor activity. There was significant difference in the activity of the coagulation factor assay based on age. The VIII (p<0.0001) and IX (p=0.0050) in the lower group of samples from those over sixty years of age is higher than from those under sixty. In contrast, XII (p=0.0285) for samples over sixty was lower than for samples under sixty. While in the upper group V (p=0.0219), VIII (p=0.0005), and IX (p=0.0014) for samples from the over sixty group was higher than those under sixty. In the case of activity of coagulation factor between O and non-O blood type, VIII (p<0.001) activity of the non-O blood type was higher than that of the O blood type in the both groups. The XII (p=0.016) activity of non-O blood type was lower than that of O blood type in the upper group. According to the multiple logistic regression analysis, when other variables are under the same conditions between lower and upper groups, there is a strong possibility for the lower group when activity of V (p=0.001), VIII (p<0.001), X (p<0.001) and XII (p<0.001) is increased. Furthermore, there is also a strong possibility of upper group when activity of II (p=0.004) and IX (p=0.012) is increased. However, no significant difference in between sex, age and XI was observed.

Effect of Coagulation Condition on Coagulation/Ultrafiltration Membrane Process (응집·한외여과 공정에서 응집조건 결정에 관한 연구)

  • Moon, Seong-Yong;Lee, Sang-Hyup;Kim, Seung-Hyun;Moon, Byung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.379-384
    • /
    • 2005
  • In this research, coagulation was employed as the pretreatment for membrane process. The effective coagulation conditions were decided after the discussion of different coagulant doses and mixing conditions, etc. Raw water was taken from Nakdong River. The best operation occurred when G value was $230s^{-1}$ and the slow mixing lasted around 5 minutes at G value was $23s^{-1}$. To investigate the optimum coagulant dosage, the optimum organics removal was target as organic removal reduces membrane fouling effectively than particle removal. This result indicated that organics are more important causes than turbidity for membrane fouling. However, turbidity becomes an important factor after certain amount of organic matters is removed.