• Title/Summary/Keyword: coagulants

Search Result 249, Processing Time 0.027 seconds

Formation, Breakage and Reformation of Humic Flocs by Inorganic and Organic Coagulants

  • Kam, Sang-Kyu;Lee, Min-Gyu;Kang, Kyung-Ho;Xu, Mei-Lan
    • Journal of Environmental Science International
    • /
    • v.17 no.3
    • /
    • pp.275-285
    • /
    • 2008
  • The floc formation, breakage and reformation of humic acid by inorganic (alum and PAC) and organic coagulants (cationic polyelectrolytes) at several conditions (pH, ionic strength and floc breakage time) were examined and compared among the coagulants at different conditions using a continuous optical monitoring method, with controlled mixing and stirring conditions. For alum, the shapes of formation, breakage and reformation curves at different pH (5 and 7) were different, but the shapes and the sizes of initial floc and reformed floc were nearly the same in the absence and presence of electrolytes at pH 7. For PAC, similar shapes of the curves were obtained at different pH and ionic strength, but the sizes were different, except for those of reformed flocs at different pH. However, for these coagulants, reformed flocs after floc breakage, occurred irreversibly for all the conditions used in this study. For organic coagulants, the time to attain the initial plateau floc size, the extent of floc strength at high shear rate and reversibility of reformed floes were different, depending floc formation mechanism. Especially, for the cationic polyelectrolyte forming humic flocs by charge neutralization or electrostatic patch effect mechanism, reformed flocs occurred reversibly, regardless of pH and floc breakage time, but occurred irreversibly in the presence of electrolytes.

Comparison of Al(III) and Fe(III) Coagulants for Improving Coagulation Effectiveness in Water Treatment (정수처리 응집효율 개선을 위한 Al(III)염과 Fe(III)염 응집제의 비교)

  • Han, Seung woo;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.325-331
    • /
    • 2015
  • The experimental results of the characteristics of aluminum based and ferric based coagulants for the Nakdong River water showed that the main hydrolysis species contained in alum and $FeCl_3$ are monomeric species of 98% and 93.3%, respectively. The PACl of r=1.2 produced by the addition of base contained 31.2% of polymeric Al species and the PACl of r=2.2 contained 85.0% of polymeric Al species, as showing more polymeric Al species with increasing r value. Coagulation tests using Al(III) and Fe(III) salts coagulants for the Nakdong River water showed that the coagulation effectiveness of turbidity and organic matter was high in the order of $FeCl_3$ > PACl (r=2.2) > PACl (r=1.2) > alum. $FeCl_3$ has showed better flocculation efficiency than Al(III) salts coagulants. In addition, in case of Al(III) coagulants, the Al(III) coagulants of higher basicity, which contained more polymeric Al species, resulted in better coagulation efficiency for both turbidity and organic matter removed. The optimum pH range for all of the coagulants investigated was around pH 7.0 under the experimental pH range of 4.0~9.5. Especially, the highest basicity PACl (r=2.2) and $FeCl_3$ were considered as more appropriate coagulants for the removal of turbidity in the case of raw water exhibiting higher pH.

The Predilution Effect of Al-based Liquid Coagulants for the Optimal Efficacy (최적 응집 효율을 위한 Al계 액상 응집제의 희석 효과)

  • Heo, Jae-Yong;Lee, Sang-Wha
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • The coagulation efficacy of Al-based coagulants (such as Alum, PACS, and PACC) was investigated to ascertain removal efficiencies of turbidity and phosphate with variation of solution pH, coagulant dosages, and pre-dilution ratios. The efficacy of Al-based coagulants was maximized in the pH range of 6~9. Under the initial condition of pH 8, $10mg/L\;{PO_4}^{3-}$, and 20 NTU, Al-based coagulants exhibited a similar efficacy in the removal of turbidity, whereas the removal efficiency of phosphate was clearly dependent on the basicity of coagulants: Alum (0%) > PACS (45~50%) > PACC (70%). At high initial turbidity of 100 NTU, polymeric coagulants, such as PACS and PACC, exhibited a higher removal efficiency of turbidity compared to Alum. In comparison to direct injection of coagulants at low initial turbidity (20 NTU), 500~2000 times pre-diluted Alum, exhibited reduced coagulation efficacy; however, removal efficiencies of turbidity and phosphate increased with the increase of retention time. Pres-diluted PACC exhibited the enhanced coagulation efficacy followed by silght decrease of the removal efficiencies with increase of the retention time. At high initial turbidity of 100 NTU, pre-diluted Alum and PACC exhibited higher removal efficiencies of turbidity and phosphate.

Recovery of Poly(3-hydroxybutyrate) from the Coagulated Cells of Alcaligenes eutrophus. (응집 처리한 Alcaligenes eutrophus 균체로부터 poly(3-hydroxybutyrate)의 회수)

  • 조경숙;홍은화;류희욱;장용근
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.3
    • /
    • pp.206-212
    • /
    • 1998
  • The effects of the pretreatment with coagulants on the recovery efficiency of poly (3-hydroxybutyrate, PHB) synthesized in Alcaligenes eutrophus were investigated. Al-base or Fe-base coagulants, and the dispersion method of 30% hypochlorite solution and chloroform were used as coagulants and PHB recovery method, respectively The recovery efficiency of PHB from the cells harvested with Al-base coagulants at the range from 0 to 1000 mg-Al/L was similar to that from cells harvested without the coagulants. At these conditions, the concentrations of residual aluminium in the purified PHB were below 250 mg-Al/kg-PHB, indicating the effect of residual aluminum on the characteristics of the purified PHB can be insignificant. When the dosage of coagulants was over 1000 mg-Al/L, the PHB recovery remarkably decreased with increasing the coagulant dosage. However, the PHB recovery could be enhanced by the use of 50% hypochlorite solution instead of 30% hypochlorite solution. Even though the reduction of PHB recovery efficiency was not found by using Fe-base coagulants, the purified PHB was stained pale red due to residual iron, These results suggest that the use of Al-base coagulants did not exert bad influence on neither PHB recovery efficiency and PHB purity.

  • PDF

Removal of Cs and Sr in Water Using Chemical and Natural Coagulants (화학 및 천연 응집제를 이용한 수중 Cs, Sr 제거)

  • Kim, Seongbeom;Kim, Youngsug;Kang, Sungwon;Oh, Daemin;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.662-666
    • /
    • 2016
  • This study investigated removal of radionuclides (Cs, Sr) in surface water by coagulation and precipitation. Jar tests were conducted with various chemical and natural coagulants to remove the stabilized radionuclides ($^{133}Cs$, $^{88}Sr$). Chemical coagulants included aluminum sulfate, poly aluminum chloride, and poly aluminum hydroxide chloride silicate (PACS); natural coagulants (minerals) included illite and zeolite. Chemical coagulant alone could achieve removals of Cs and Sr less than 10%; The removals increased up to 23.1% for Cs and 17.8% for Sr with addition of poly-dimethyldiallylammonium chloride (polyDADMAC) along with the chemical coagulants. Compared with chemical coagulants, natural coagulants (minerals) could achieve higher removals of Cs and Sr. Addition of zeolite along with PACS and polyDADMAC increased the removal rates up to 36.9% for Cs and 17.1% for Sr.

Improving the Initial Effluent Water Quality of Rapid Sand Filter by Coagulants Injection (응집제주입에 의한 급속모래여과에서 초기유출수의 수질향상)

  • Kim Woo-Hang;Jeon Ji-Hoon
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.237-242
    • /
    • 2006
  • The purpose of this research was to investigate the efficiency of coagulants dose after backwashing. The turbidity of initial effluent was high after backwashing in the rapid sand filtration and the high turbidity was almost removed by coagulants dose into filter-sand after backwashing. It was found that the turbidity of initial effluent was well removed by all kinds of the coagulants used in this study. When filtration was performed input water with differentiated pH's, the turbidity of effluent was low at the range of pH 5 - pH 7. But the removal was not good about over pH 9. This result was considered into the existence forms of aluminium, $Al(OH)^{2+}\;and\;{Al(OH)_2}^+$ at pH 5. Cryptosporidiums of effluent were 4/ml for ten minutes immediately after back washing and 3/ml until sixty minutes. However, the case of coagulant dose after backwashing, Cryptosporidiums of effluent were 0.5/ml for ten minutes with no detection after twenty minutes.

Selection of coagulant using jar test and analytic hierarchy process: A case study of Mazandaran textile wastewater

  • Asadollahfardi, Gholamreza;Zangooei, Hossein;Motamedi, Vahid;Davoodi, Mostafa
    • Advances in environmental research
    • /
    • v.7 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • Textile factories are one of the industries which its wastewater treatment is a challenging issue, especially in developing countries and a conventional treatment cannot treat all its pollutants properly. Using chemical coagulants is a technique for physical and chemical primary treatment of the wastewater. We applied jar test for selection of suitable coagulant among the five coagulants including alum, calcium hydroxide, ferrous sulfate, ferrous chloride and barium chloride for the effluent of wastewater in Mazandran textile factory located in Mazandran Province, Iran. In addition, jar test, we also used analytic hierarchy process (AHP) method considering criteria which included coagulation cost, sensitivity to pH change, the amount of sludge generation and side effects for coagulation. The results of the jar test indicated that calcium hydroxide was proper among the coagulants which it removed 92.9% total suspended solid (TSS), 70% dye and 30% chemical oxygen demand. The AHP analysis presented that calcium hydroxide is more suitable than other coagulants considering five criteria.

Characteristics of Tofu Coagulants Extracted from Sea Tangle Using Treated Deep Ocean Water (해양심층수를 이용한 다시마 추출물의 두부응고제 특성)

  • Lee, Seung-Won;Kim, Hyeon-Joo;Moon, Deok-Soo;Kim, Ah-Ree;Jeong, In-Hak
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.3
    • /
    • pp.113-116
    • /
    • 2007
  • We investigated the characteristics of various Tofu coagulants extracted from sea tangle using treated deep ocean water (DOW) as the solvents. The coagulants were typical solutions extracted from sea tangle using raw DOW and strongly electrolyzed acidic (SAC) or alkaline (SAK) water. The total dissolved solids (TDS), NaCl and electric conductivity were increased in the coagulant solution extracted by SAC than the others. In the coagulant solutions extracted by acidic electrolyzed solvent, aspartic acid content (13.5 mg/100 g) was higher than others (11.2 and 12.1 mg/100 g). The Tofu obtained using coagulants extracted with treated DOW had the water contents ranging from 79.55% to 80.04%. The contents of crude protein (12.1 g/100 g) and Na, Ca, K and Mg were relatively higher than general Tofu commercially available. Therefore, coagulant solutions extracted from sea tangle using treated DOW can be used to develop natural high-grade tofu for practical use.

The Feasibility Study of CMP Wastewater Treatment Using Tubular Membrane and Coagulants (응집제와 관형막을 활용한 CMP 폐수 처리 가능성 연구)

  • Jung, Ho Chan;Jung, Cheol Joong;Song, Ja Yeon;Kim, Youn Kook;Lee, Sun Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.639-645
    • /
    • 2012
  • The purpose of this study is to identify the possibility of the CMP wastewater treatment from semiconductor fabrication under operating tubular membrane with coagulants. To find suitable coagulants treating CMP wastewater, we conducted Jar-test. After Jar-test experiments suitable coagulants are PAC(17%), $Ca(OH)_2$ and optimum coagulant dosage is PAC(17%) 10mg/L, $Ca(OH)_2$ 110 ~ 120mg/L. Based on these results, the tubular membrane was applied to CMP wastewater, the turbidity removal efficiency is $Ca(OH)_2$ > PAC(17%) > Nothing. The fast cross-flow velocity and backwash process what are operating characteristics of tubular membrane can be stable CMP wastewater treatment. But when the coagulant and tubular membrane are used at the same time, the withdraw and treatment of the CMP wastewater are possibile. However further treatment process needs if treated water will be used for semiconductor fabrications.

Utilization of Organic Polymers for Improvement of Drinking Water Treatment Process (정수공정 개선을 위한 유기성 Polymer의 사용)

  • Lee, Hwa-Ja;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.217-222
    • /
    • 1998
  • Organics matters including algae are the major contaminants of Nak-dong river and it's concentration Is more Increasing now. The use of coagulants has been Incresed for the effective treatment of drinking water, and aluminum coagulants have been the most widely used in raw water treatment. However, when inorganic metal coagulant is excessively used for long period, it would result in secondary problems, such as increasing sludge production, enhancing the cost of water treatment process, and increasing concentration of residual metal, especially aluminum. Therefore, recently. in order to reduce the use of metal coagulant and enhance the coagulation effectiveness, several alternative coagulants, such as polymeric Inorganic coagulants and organic polymers, have been used In water treatment plants. The objectives of thins research were (11 to determine optimum dosage concentration and compare the coajuiation efnciency at various pH ranees with alum alone, alum+cationic polymer, and alum+anlonlc polymer, (21 to evaluate the amount of alum reduced by using organic polymer, (31 to maximize removal officiency of organic matter and minimize the concentration of residual aluminum.

  • PDF