• Title/Summary/Keyword: co-operation performance

Search Result 675, Processing Time 0.035 seconds

Geomechanical assessment of reservoir and caprock in CO2 storage: A coupled THM simulation

  • Taghizadeh, Roohollah;Goshtasbi, Kamran;Manshad, Abbas Khaksar;Ahangari, Kaveh
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.75-90
    • /
    • 2019
  • Anthropogenic greenhouse gas emissions are rising rapidly despite efforts to curb release of such gases. One long term potential solution to offset these destructive emissions is the capture and storage of carbon dioxide. Partially depleted hydrocarbon reservoirs are attractive targets for permanent carbon dioxide disposal due to proven storage capacity and seal integrity, existing infrastructure. Optimum well completion design in depleted reservoirs requires understanding of prominent geomechanics issues with regard to rock-fluid interaction effects. Geomechanics plays a crucial role in the selection, design and operation of a storage facility and can improve the engineering performance, maintain safety and minimize environmental impact. In this paper, an integrated geomechanics workflow to evaluate reservoir caprock integrity is presented. This method integrates a reservoir simulation that typically computes variation in the reservoir pressure and temperature with geomechanical simulation which calculates variation in stresses. Coupling between these simulation modules is performed iteratively which in each simulation cycle, time dependent reservoir pressure and temperature obtained from three dimensional compositional reservoir models in ECLIPSE were transferred into finite element reservoir geomechanical models in ABAQUS and new porosity and permeability are obtained using volumetric strains for the next analysis step. Finally, efficiency of this approach is demonstrated through a case study of oil production and subsequent carbon storage in an oil reservoir. The methodology and overall workflow presented in this paper are expected to assist engineers with geomechanical assessments for reservoir optimum production and gas injection design for both natural gas and carbon dioxide storage in depleted reservoirs.

The Monitoring System for Location of Workers Inside a Thermal Power Plant Boiler (화력 발전기 보일러 내부 작업자 위치 모니터링 시스템 개발)

  • Song K.;Yun, C.N.;Shin, Y.H.;Shin, J.H.;Han, S.H.;Jang, D.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.71-78
    • /
    • 2021
  • There are regularly planned overhaul periods in thermal power plants, which involve the maintenance of the boiler of the power plants. However, thermal power plants workers are always exposed to risk during overhaul periods owing to the narrow space and significant dust inside the boiler. Therefore, it is essential to develop a safety monitoring system that is suitable for operating in this type of environment. In this study, we developed not only a worker three-dimensional (3D)-location monitoring system that can monitor and record the entry/exit of workers, their 3D-location, and fall accidents but also a method to secure the working environment and operation efficiency. This system comprises of a worker tag, which was equipped with an inertial measurement unit, a barometric pressure sensor, and a Bluetooth low energy (BLE), and the tags were given to each worker. In addition, the location of workers inside the boiler was measured using a pedestrian dead reckoning (PDR) method and BLE beacons. The location data of the workers tag were transmitted to the integrated database (DB) server through a gateway, and to the administrator monitoring system. The performance of the system was demonstrated inside an actual thermal power plant boiler, and the accuracy and reliability of the system were verified through a number of repeated tests. These results provide insights on designing a new system for monitoring enclosed spaces.

Performance Evaluation of Combined Sewer Overflow Treatment using Filtration Pilot Device (파일럿 여과장치를 이용한 합류식하수관 월류수 처리성능 평가)

  • Lee, Jun Ho;Shin, Young Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.5
    • /
    • pp.409-417
    • /
    • 2019
  • In this study, a $480m^3/day$ pilot device was constructed through laboratory experiments based on the Ministry of Environment manual. The purpose of this study was to analyze the characteristics of CSO treatment and backwashing characteristics by applying the pilot device to the field. The purpose of this study was to acquire the basic data necessary for the design and operation management of the real scale filtration type non-point pollution control system. The filtration was conducted while maintaining the linear velocity of 20m/hour. The CSO treatment efficiencies of the pilot devices were 0.4-76.1%(mean 49.0 %), SS 51.4-91.6%(mean 77.8%), COD 22.2-59.4% (mean 38.3%) and TP 14.5-52.6%(mean 38.1%),respectively. The correlation coefficient between SS and the turbidity of influent water was 0.90, higher than that of CSO. To operate the treatment system effectively, the turbidity can be easily measured in real time as the monitoring item is the most appropriate because SS is the main target substance of the non-point source. As a result of analyzing the adsorbent treatment characteristics of PP filter material applied to this pilot device, the average particle diameter range of influent was $4.6-40.1{\mu}m$(mean $21.2{\mu}m$) and the treated water was $0.9-24.5{\mu}m$(mean $6.4{\mu}m$), respectively. Particles of approximately 10m or less are leached out, and so it is necessary to compensate for the raw water containing micro particulate matter.

The performance of combined heat and power plant according to gas turbine air mass flow rate change (가스터빈 공기량 조절에 따른 열병합발전 성능 변화)

  • Kim, Jae-Hoon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.32-40
    • /
    • 2022
  • In this study, we investigated the operation data of combined heat and power in accordance with the change of the inlet guide vane with partial load. The partial load 80% could close the inlet guide vane up to 24%, and the exhaust gas temperature could be increased by 52℃. The partial load 90% could close the inlet guide vane up to 12%, and the exhaust gas temperature could be increased by 23℃. At 80% of partial load with the thermal load tracking mode, the output could be increased up to 5.68 MW, the combined cycle efficiency increased by 0.73%, and the combined heat and power efficiency increased by 1.81%. At 90% of the partial load, the output could be increased up to 2.55 MW, the combined cycle efficiency increased by 0.32%, and the combined heat and power efficiency increased by 0.72%.

  • PDF

A Study on Ground and Object Separation Techniques Utilizing 3D Point Cloud Data in Urban Air Mobility (UAM) Environments (UAM 환경에서의 3D Point Cloud Data 지면/객체 분리 기법 연구)

  • Bon-soo Koo;In-ho choi;Jae-rim Yu
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.481-487
    • /
    • 2023
  • Recently, interest in UAM (Urban Air Mobility) has surged as a critical solution to urban traffic congestion and air pollution issues. However, efficient UAM operation requires accurate 3D Point Cloud data processing, particularly in separating the ground and objects. This paper proposes and validates a method for effectively separating ground and objects in a UAM environment, taking into account its dynamic and complex characteristics. Our approach combines attitude information from MEMS sensors with ground plane estimation using RANSAC, allowing for ground/object separation that isless affected by GPS errors. Simulation results demonstrate that this method effectively operates in UAM settings, marking a significant step toward enhancing safety and efficiency in urban air mobility. Future research will focus on improving the accuracy of this algorithm, evaluating its performance in various UAM scenarios, and proceeding with actual drone tests.

Dynamic Characteristics and Instability of Submerged Plain Journal Bearings in accordance with the Cavitation Model (공동현상 모델에 따른 침수형 평면 저널베어링의 동특성 및 회전 안정성에 대한 연구)

  • Moonho Choi
    • Tribology and Lubricants
    • /
    • v.39 no.4
    • /
    • pp.139-147
    • /
    • 2023
  • Cavitation phenomena observed during the operation of a submerged plain journal bearing (PJB) can affect bearing performance parameters such as dynamic coefficients, whirl frequency ratio, and critical mass. This study presents numerical solutions of the Reynolds equation for steadily and dynamically loaded submerged PJBs with half-Sommerfeld (HS), Reynolds, and Jakobsson-Floberg-Olsson (JFO) cavitation models when the supply pressure is larger or equal to the cavitation pressure. The loads at various eccentricity ratios are identical; however, the attitude angle is approximately 6% smaller when the eccentricity ratio is between 0.2 and 0.7 and the JFO model is used, compared to that when the Reynolds model is used. Dynamic coefficients obtained with the HS and Reynolds model show good agreement with each other, except for kxz, which is sensitive to changes in the force normal to the rotor weight, and is attributed to the difference in the attitude angle obtained with each cavitation model. Stiffness coefficients are determined using the pressure distribution in the film, and therefore, when the JFO model is used, the direct stiffness coefficients are affected and show opposite signs for most eccentricity ratios. The mass-conservative JFO model can predict at least a 30% smaller critical mass compared to that using the HS and Reynolds models. Thus, the instability analysis results can change based on the cavitation model used in a submerged PJB. The results of this research indicate that the JFO model should be used when designing a rotor system supported by submerged PJBs.

Development of a Packet-Switched Public Computer Network -PART 3:X.25 Software Design and Implementation of the KORNET NNP (Packet Switching에 의한 공중 Computer 통신망 개발 연구-제3부:KORNET NNP의 X.25 Software 설계 및 구현)

  • Choi Jun Kyun;Kim Nak Myeong;Kim Hyung Soon;Un Chong Kwan;Im Gi Hong;Cho Young Jong;Cho Dong Ho
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 1986
  • This is the third part of the four-part paper describing the development of a packet-switched computer communication network named the KORNET. In this paper we describe the design and implementation of the X.25 protocol connecting packet mode data terminal equipments(PDTE's) with data circuit terminating equipments(DCE's). In the KORNET, the X.25 protocol has been implemented on the line processing module-A(LPMA) of the network node processor(NNP). In the implementation of X.25, we have divided the software module according to the service function, and have determined the the rules that interact between the modules. Each layer protocol has been developed using the technique of the finite state machine. Before the actual coding of softwares, we hafve used formal software development tools based on the specification and description language (SDL) and program design languate (PDL) recommended by the CCITT. In addition, for the efficient operation of the X.25 protocol system we have analyzed the system performance and the service scheduling method of each module. The results will also be given.

  • PDF

Porting gcc Based eCos OS and PROFINET Communication Stack to IAR (gcc 기반 eCos 운영체제 및 PROFINET 통신 스택의 IAR 포팅 방법)

  • Jin Ho Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.4
    • /
    • pp.127-134
    • /
    • 2023
  • This paper describes how to port the eCos operating system and PROFINET communication stack developed based on gcc to the IAR compiler. The eCos operating system provides basic functions such as multi-thread, TCP/IP, and device driver for PROFINET operation, so there is no need to change it when developing PROFINET applications. Therefore, in this study, we reuse an eCos library built with gcc and it link with PROFINET communication stack that are ported to IAR complier. Due to the different of the gcc and IAR linker, symbol definitions and address of the constructors should be changed using the external tool that generates symbol definitions and address of the constructors from MAP file. In order to verify the proposed method, it was confirmed that the actual I/O was operating normally through PROFINET IRT communication by connecting to the Siemens PLC. IAR compiler has better performance in both the compile time and the size of the generated binary. The proposed method in this study is expected to help port various open sources as well as eCos and PROFINET communication stacks to other compilers.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.

Anaerobic digestion for food wastewater using HADS Pilot Plant and analysis of microbial community in the digester (HADS Pilot Plant를 이용한 음폐수의 혐기성 소화 및 미생물 군집 변화 분석)

  • Ju, Dong-Hun;Lee, Jung-Min;Park, Seong-Bum;Sung, Hyun-Je;Bae, Jae-Sang;Sang, Byoung-In
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2010
  • We(Hansol EME Co. Ltd.) proceeded anaerobic digestion test for domestic food wastewater applying to two operating method for increasing of OLR. The methods are as follows. One was the rapidity operating method which was increasing the OLR continuously and rapidly and the other was the terraced operating method which was increasing the OLR having adaptation period for each step. As a result of this tests, the ratio of VFA/Alkalinity of the process was very unstable under the rapidity operating method then the volume of produced biogas was dramatically decreased. However the process was shown stable performance under the terraced operating method maintaining the ratio of VFA/Alkalinity less than 0.4. Also, the process was performing the biogas recovery of $0.8Nm^3/kgVS_{rem}/d$ and the VS removal ratio of 85%. T-RFLP analysis about the community of bacteria and methanogen is also conducted to check the change of the microbial community according to the methods of OLR increasing operation. The microbial community was changed by the methods of OLR increasing operation according to the result of T-RFLP analysis. Although the anaerobic digestion test was executed by same pilot plant, the reactivity and the tolerance of microbial community for surrounding environment could be considerably changed by the operating method for the process.