• Title/Summary/Keyword: co-operation performance

Search Result 675, Processing Time 0.026 seconds

Indicator of Facility Performance Evaluation (FPE) for Educational Facilities of BTL Projects

  • Lee, Kwan-Jong;Lee, Chun-Kyong;Park, Tae-Keun
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • Build-Transfer-Lease (BTL) was introduced to the domestic construction market in 2005. Now, seven years later, the BTL model is most active for educational facilities. In 2011, 93 educational facility projects entered the maintenance stage. Considering the characteristics of today's BTL projects for educational facilities, the main issues are the initial performance and maintenance of educational facilities and the service-providing status for the 20-year operational management period, in relation to providing safety and convenience to students, the facility users. Seeking a solution, local education offices and departments in charge of BTL under the Ministry of Education, Science, and Technology have been exploring various methods of evaluating operational maintenance performance from various perspectives. For educational facility BTL projects, however, the appropriateness of initial operation performance evaluation, rather than considering the 20-year operational management period, is controversial in regards to sustainability. On this account, performance evaluation items in four areas-operational maintenance evaluation, facility performance status evaluation, maintenance subject evaluation, and sustainable change response evaluation-should be extracted. An indicator of facility performance evaluation is presented in this study through an AHP survey targeting experts, as part of establishing an operation performance evaluation system for educational facility BTL projects.

Development of High Performance Sensorless Vector Inverter Using TMS320F2812 (TMS320F2812를 이용한 고성능 센서리스 벡터제어 인버터 개발)

  • Jeong S.J.;Kim S.K.;Kim S.H.;Shin H.J.;Han K.J.;Lee S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.107-109
    • /
    • 2006
  • The purpose of this paper is to introduce the new products for replacing on the old technical cooperation products which have 24 kinds of industrial inverter model. The core algorithm for vector control and sensorless control and the operation program for LCD operator have been developed. Through the continuous test, the improvement of speed/torque control performance and the control program for special target loads will be performed.

  • PDF

Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack (교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가)

  • Lim, H.C.;Seol, J.H.;Ryu, C.S.;Lee, C.W.;Hong, S.A.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 1995
  • A 100kW class stack consisting of 10 molten carbonate fuel cells has been fabricated. Internally manifold stack has been tested for endurance. Each cell in the stack had an electrode area of $100cm^2$ and reactant gases were distributed in each cells in a cross-flow configuration. Initial and long term operation performance of the stack was investgated as a function of gas utilization using a specially designed small scale stack test facility. It was possible to have a stack with an output of more than 100W using an anode gas of 72% $H_2/18%$ $CO_2/10%H_2O$ and cathode gas of 33% $O_2/67%$ $CO_2$ and 70% Air 30% $CO_2$. The output and voltage of the stack at a current 15A($150mA/cm^2$) and gas utilization of 0.4 showed 125.8W and 8.39V respectively by elapsed time of 310 hours operation. In long term operation characteristics, the voltage drop of 52.4mV/1000hour was observed after more than 1,840 hours operation. Among the voltage drop, the OCV loss was highest than other voltage loss such as internal resistance and electrode polarization. Non uniformity of 2voltages and degradation of cell voltage in the stack was observed in according to changing the utilization rate after a long term operation. Further work for increasing the performance prolonging the life of the stack are required.

  • PDF

Whole-working history analysis of seismic performance state of rocking wall moment frame structures based on plastic hinge evolution

  • Xing Su;Shi Yan;Tao Wang;Yuefeng Gao
    • Earthquakes and Structures
    • /
    • v.26 no.3
    • /
    • pp.175-189
    • /
    • 2024
  • Aiming at studying the plastic hinge (PH) evolution regularities and failure mode of rocking wall moment frame (RWMF) structure in earthquakes, the whole-working history analysis of seismic performance state of RWMF structure based on co-operation performance and PH evolution was carried out. Building upon the theoretical analysis of the elastic internal forces and deformations of RWMF structures, nonlinear finite element analysis (FEA) methods were employed to perform both Pushover analysis and seismic response time history analysis under different seismic coefficients (δ). The relationships among PH occurrence ratios (Rph), inter-story drifts and δ were established. Based on the plotted curve of the seismic performance states, evaluation limits for the Rph and inter-story drifts were provided for different performance states of RWMF structures. The results indicate that the Rph of RWMF structures exhibits a nonlinear evolution trend of "fast at first, then slow" with the increasing of δ. The general pattern is characterized by the initial development of beam hinges in the middle stories, followed by the development towards the top and bottom stories until the beam hinges are fully formed. Subsequently, the development of column hinges shifts from the bottom and top stories towards the middle stories of the structure, ultimately leading to the loss of seismic lateral capacity with a failure mode of partial beam yield, demonstrating a global yielding pattern. Moreover, the limits for the Rph and inter-story drifts effectively evaluate the five different performance states of RWMF structures.

Simulation Study on the Performance Characteristics of $CO_2$ microchannel gascooler with Operation Conditions ($CO_2$용 마이크로채널 가스쿨러의 운전조건 변화에 따른 성능특성에 관한 해석적 연구)

  • Shin, Eun-Sung;Bae, Kyung-Jin;Kim, Byeong-Cheol;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1090-1095
    • /
    • 2009
  • The purpose of this study is to determine the performance characteristics for the micro-channel gascooler with various operating conditions. The performance of four kind of HX models were analyzed and optimized with the variation of refrigerant inlet temperature, air velocity, outdoor temperature. As a result, Model B showed the maximum capacity and high performance could be maintained for wide operating conditions. Beside, the micro-channel heat exchanger could be appled to $CO_2$ system appropriately because of a small pressure drop and high heat transfer rate.

  • PDF

Techno-Economic Study on Non-Capture CO2 Utilization Technology

  • Lee, Ji Hyun;Lee, Dong Woog;Kwak, No-Sang;Lee, Jung Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.109-113
    • /
    • 2016
  • Techno-economic evaluation of Non-Capture $CO_2$ Utilization (NCCU) technology for the production of high-value-added products using greenhouse gas ($CO_2$) was performed. The general scheme of NCCU process is composed of $CO_2$ carbonation and brine electrolysis process. Through a carbonation reaction with sodium hydroxide that is generated from brine electrolysis and $CO_2$ of the flue gas, it is possible to get high-value-added products such as sodium bicarbonate, sodium hydroxide, hydrogen & chloride and also to reduce the $CO_2$ emission simultaneously. For the techno-economic study on NCCU technology, continuous operation of bench-scale facility which could treat $2kgCO_2/day$ was performed. and based on the key performance data evaluated, the economic evaluation analysis targeted on the commercial chemical plant, which could treat 6 tons $CO_2$ per day, was performed using the net present value (NPV) metrics. The results showed that the net profit obtained during the whole plant operation was about 7,890 mKRW (million Korean Won) on NPV metrics and annual $CO_2$ reduction was estimated as about $2,000tCO_2$. Also it was found that the energy consumption of brine electrolysis is one of the key factors which affect the plant operation cost (ex. electricity consumption) and the net profit of the plant. Based on these results, it could be deduced that NCCU technology of this study could be one of the cost-effective $CO_2$ utilization technology options.

Development of General-Purpose Remote Maintenance Controller Gateway for Multi-Modal Photovoltaic Equipment (이기종 태양광 설비 지원을 위한 범용 RMC 게이트웨이 개발)

  • Lim, Su-Chang;Hong, Seok-Hoon;Park, Chul-Young;Song, Beob-Seong;Kim, Jong-Chan
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.10
    • /
    • pp.1307-1317
    • /
    • 2020
  • In recent years, the PV plant is gradually increasing in korea and has begun to focus on PV system O&M(Operation and Management). The legacy PV system can hardly be gathering realtime information. That is why it is difficult for the facility to respond immediately to situations in which problems arise. This leads to economic losses due to reduced power generation. In this study, we implemented an RMC(Remote Maintenance Control) gateway that supports multi-area equipment(inverters, junction boxes, switchboards, environmental sensors) that are not limited to specific manufacturers. It provides a function to visualize the collected data. Users can easily check the power generation and operation status of PV system equipment. In the future, we will develop an algorithm capable of analyzing beta factors that cause equipment performance degradation, parts aging, and deterioration using data collected from facilities. We intend to use this algorithm as a fundamental technology for O&M by transplanting it to the RMC gateway.

A Design of Advanced Distribution Management System Based on IT/OT Convergence (IT/OT Convergence 기반의 Advanced Distribution Management System의 설계)

  • Lim, Il-Hyung;Lee, Seung-Joo;Park, Jong-Ho;Shin, Yong-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.753-759
    • /
    • 2016
  • Power automation system to operate power distribution systems can be distinguished by distribution SCADA with remote monitoring and control; and distribution automation system with basic functions such as service restoration to the distribution SCADA; and distribution management system which is operated by various applications in order to enhance distribution system operation performance based on the distribution automation system. In the technological change, a technical boundary of information technology (IT) and operation technology (OT) is being blurred by that new concepts such as interoperability. In addtion, IT/OT convergence has been proposed by the improvement of ICT and power system technology. At the viewpoint, advanced distribution management system (ADMS) to have the new concepts and to increase distribution system operation efficiency through global information and functions from the other systems has been proposed. In order to implement the ADMS, IT and OT have to be employed together on the ADMS; and the concept-based IT/OT convergence concept has been presented. Therefore, this paper introduces ADMS and IT/OT convergence and proposes a design of IT/OT convergence based ADMS system design with configurations and functions.

Optimization of Fuel Processing Unit of Fuel Cell System using Six-Sigma Technique (Six-sigma 기법을 이용한 연료전지시스템 연료저리장치 최적화)

  • Chung, Kyung-Yong;Kim, Sun-Hoe
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.225-229
    • /
    • 2012
  • A reformer for a small fuel cell system is an apparatus which converts hydrocarbon fuel into hydrogen-rich gas. Among many indices of a reformer, the most crucial index of a reformer is CO concentration in the off-gas out of reformer which must be controled under 5ppm for the efficiency and performance of a system. This paper suggests the criteria of a reformer operation for the stability of a reformer in a fuel cell system by deducing crucial indices and improving processes. The six-sigma technique was applied to verify the optimum control and operation of a reformer of a fuel cell combined heat and power system. The result of temperature control of each parts of a reformer system is the concentration of CO which is the most important factor for the operation of a fuel cell system. The temperature of the parts of a reformer, MTS, LTS and Prox, were controled so that the concentration of CO.

Characterization of the Effects of Relative Humidity and Bed-depth on $CO_2$ Capture for Maximizing the Utilization Rate of Soda Lime Sorbent

  • Cho, Il-Hoon;Park, Guen-Il;Kim, Joon-Hyung;Hwang, Taek-Sung;Lee, Mi-Kyoung
    • Carbon letters
    • /
    • v.2 no.2
    • /
    • pp.113-119
    • /
    • 2001
  • The advanced method for $CO_2$capture is currently one of the most important environmental issues in worldwide and it is therefore necessary to have available technologies, which minimize the discharge of $CO_2$ including Carbon-14 from nuclear facilities into the atmosphere. A key aspect of this work is to provide the technically principal data required to improve a $CO_2$ removal system for the utilization of regenerative sorbent use, specifically include suggestions regarding its modified column design (parallel dual-bed assembly), stop-restart operation and the economic feasibility of sorbent use. The removal performance of soda lime and the effects of relative humidity (RH) and packing bed-depth (BD) on $CO_2$ removal were investigated. In a single-bed, it revealed that the utilization of soda lime for $CO_2$ removal at line velocity of 13 cm/sec and bed depth of 12 cm increased with the increased relative humidity up to 85%. However, in the parallel dual-bed assembly applied with the stop-restart operation, a maximum utilization rate of soda lime for $CO_2$ removal was obtained even at 55% of RH and 8 cm of BD, specifically the utilization rate of soda lime by using this $CO_2$ removal assembly was about two-fold superior to that in a single-bed.

  • PDF