• Title/Summary/Keyword: co-located

Search Result 1,053, Processing Time 0.034 seconds

A study on the overhaul method for a Tandem type EDG on Nuclear Power Plant (원자력발전소 Tandem 형 비상디젤발전기의 최적 정비 방안 연구)

  • Han, Sung-Heum;Lim, Woo-Sang;Ha, Che-Wung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2036-2037
    • /
    • 2008
  • An Emergency Diesel Generator (EDG) manufactured by a French company Wartsila SACM, is a tandem type engine, consisted of two 10 cylindered diesel engines on each side. Manual provided by the manufacturer states that engine bearing requires inspection every 15 years. However, it is difficult for an inspector to access through a manhole located in the lower compartment of engine. Furthermore, during a routine or scheduled maintenance, it is not possible to disassemble main engine bearing and crank shaft, and perform inspection. Two methodologies are suggested here to resolve the problem. One method is to lift the engine and partially perform the maintenance service, and the other method is to disassemble the engine completely and to perform maintenance service by the manufacturer. Pros and cons of two methodologies were thoroughly compared.

  • PDF

A LIQUID DROPLET SIMULATION ON ZIG-ZAG MOTION (단일 액적의 Zig-Zag 운동 시뮬레이션)

  • Jung, Rho-Taek
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.63-68
    • /
    • 2009
  • The motion of a rising liquid droplet is different that of a bubble motion. Treatment of liquid drops is more complex because internal motion must be considered. A 3D unstructured CFD code has been developed to solve incompressible N-S equation for the droplet simulation. This front-tracking consideration which the interface is tracked explicitly is very available to apply for not only exact interface topology but also the high schmidt number issue, such as $CO_2$ dissolution. This paper is forced on the zig-zag motion of the liquid droplet. The simulation shows that if the rising droplet is located at the corner of the zig-zag path, the velocity is low and shape of the droplet is more spherical shape, results in the less drag coefficient. Twin horse shoe vortexes behind the rising droplet are presented and the topology of the droplet is compared with an experimental result during one period of the path.

Novel Beamforming and Scheduling Method for Interference Mitigation at Cell Edge (셀 경계 지역 간섭 완화를 위한 효율적 빔포밍 및 스케쥴링 방법)

  • Kim, Kyung Hoon;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.129-133
    • /
    • 2012
  • Coordinated multi-point transmission (CoMP) is a candidate technique for next generation cellular communications systems. One of the primary elements discussed in LTE-Advanced technology is CoMP, which can improve cell edge user data rate as well as spectral efficiency due to multiple input multiple output - orthogonal frequency division multiplex (MIMO-OFDM). We consider a system with multiple cells in which base stations coordinate with each other by sharing user channel state information (CSI), which mitigates inter cell interference (ICI), especially for users located at the cell edge. We introduce a new user scheduling method of ICI cancellation and the loss reduction of effective channel gain during the beamforming process, the proposed method improves the system sum rate, when compared to the conventional method by an average of 0.55bps/Hz in different number of total users per cell. It also outperforms the conventional method by approximately 0.38bps/Hz using different SNRs.

The Optimum Design of Green Water Protector for FPSO (FPSO - Green Water Protector 구조 최적 설계)

  • Bae, Myung-Hyun;Kim, Sung-Jun;Moon, Jung-Yang
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.94-98
    • /
    • 2007
  • The latest development of the submarine oil field and the deep-sea explorer, FPSO is commonly proposed and used for offshore oil production. And because the fundamental requirement of FPSOs to remain moored at their position, they are unable to avoid severe weather and environment. FPSO normally operates head to the weather, and sensitive equipment located the exposed area will be influenced by green water damages, the damages may occur to both onboard equipment and topside structures with resulting risk to personnel. In this paper, the main focus considers the physical structures of green water protector in order to preserve topside structures, equipment and personnel from green water.

  • PDF

A Study on the Conservation Plan of the Regional Green Space in the Tokyo Metropolitan Area - A Case Study of the Minuma Tanbo Area -

  • Hiroshi Akiyama;Sonomi Ishi;Yuki Mashimo;Sadatoshi Tabata
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.171-177
    • /
    • 2004
  • This surveillance research drafted a conservation plan of regional green spaces, on a metropolitan area level, geared toward the Minuma Tanbo area of 1260 ha, located in Saitama City, in the suburbs of Tokyo. It was an effective method, applied to an area where Japan's current issues on regional green space were epitomized, as it formed symposiums consisting of various personnel, and the opinions of the citizen had been reflected.

  • PDF

Ammonia and Carbon Dioxide Concentrations in a Layer House

  • Kilic, Ilker;Yaslioglu, Erkan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.8
    • /
    • pp.1211-1218
    • /
    • 2014
  • Higher concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in animal barns can negatively affect production and health of animals and workers. This paper focuses on measurements of summer concentrations of ammonia ($NH_3$) and carbon dioxide ($CO_2$) in a naturally ventilated laying henhouse located at an egg production facility in Bursa region, western Turkey. Also, indoor and ambient environmental conditions such as temperature and relative humidity were measured simultaneously with pollutant gas concentrations. The average $NH_3$ concentrations during summer of 2013 was 8.05 ppm for exhaust and 5.42 ppm for inlet while average $CO_2$ concentration was 732 ppm for exhaust and 625 ppm for inlet throughout summer. The overall minimum, average and maximum values and humidity were obtained as $16.8^{\circ}C$, $24.72^{\circ}C$, and $34.71^{\circ}C$ for indoor temperature and 33.64%, 63.71%, and 86.18% for relative humidity. The lowest exhaust concentrations for $NH_3$ and $CO_2$ were 6.98 ppm and 609 ppm, respectively. They were measured in early morning at the maximum diurnal ventilation rate in July 2013 and August 2013. The highest concentrations were 10.58 ppm for $NH_3$ and 904 ppm for $CO_2$ recorded in the afternoon when the ventilation rate was the lowest in June 2013.

Technical and Economic Assessment of CO2 Transportation Options for Large-scale Integrated Carbon Capture & Sequestration(CCS) Project in South Korea

  • Lee, Ji Hyun;Kim, Beom-Ju;Kwak, No Sang;Shim, Jae-Goo;Shin, Su Hyun;Hwang, Sun-Na;Lee, Jung-Hyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • In order to examine the feasibility of Carbon Capture & Sequestration, a major technological strategy for the national goal of greenhouse gas reduction, this paper studies the various methods and corresponding costs for the transportation of $CO_2$ captured at the domestic thermal power plants, as well as performing comparative analysis with overseas CCS demonstration projects. It is predicted that the investment cost would be about 98 million USD when the using land-based pipelines to transport captured $CO_2$ from the thermal power plant located in the south coast. And using marine-based offshore pipelines, it will cost about twice the amount. When the captured $CO_2$ is transported from the power plant in the west coast instead, the cost is expected to increase substantially due to the transportation distance to the storage site being more than double to that of the south coast power plant case.

A Case Study on Construction of Tunnel at Limestone Cavity Site (석회암공동 분포지역에서의 터널 시공사례)

  • Kim, Si-Kyeok;Kang, In-Seop;Kim, Yong-Ha;Yoon, Il-Byung;Moon, Hoon-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.66-75
    • /
    • 2006
  • As construction for road tunnel is increasing, various geotechnical conditions can be faced during the construction stage. Especially, if the tunnel is located in limestone area, many kinds of site investigations such as in-situ boring, electrical resistance survey, TSP(Tunnel Seismic Prediction) and etc., are conducted before and during the construction. By conducting these preliminary tests, location, size, and filling materials in limestone cavities can be approximately estimated. Once some cavities which can be harmful for tunnel safety are predicted, methods for ground reinforcement and tunnel excavation, corresponding those ground conditions, have to be established and verified by measurement data and numerical analysis. If necessary, invert lining should be also considered. In this paper, by studying some cases of tunnels constructed in limestone area, predicted problems during construction and rational countermeasures for those are presented.

  • PDF

Economic Feasibility Study for Providing Co-generation System in various Type of Apartment Complexes (아파트단지의 특성에 따른 열병합발전도입의 경제성 비교연구)

  • Gi, Woo-Bong;Kim, Gwang-Ho;Lim, Hee-Jin;Yoon, Kyung-Shick;Jang, Hyuk-Bong;Kim, Dong-Hwan
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.27-37
    • /
    • 2007
  • This study is to analyse the feasibility for providing Co-generation plant in Apartment Complex for 4 typical Apartment Complexes located Seoul metropolitan area, The selected complexes are three midium-large size Apartment[nearby 35pyoug of floor area] and one complex of small size Apartment[below 25 pyoung of floor area] for comparison. The necessary data for the study were collected with visitation of each site. The study showed very positive result for the three medium-large size Apartment Complexes of which the average floor area is more than 25 pyoungs, while negative result for the Complex of which average floor area is less than 25 pyoungs. Other than floor size it was found that the electric consumption density also influence the economic feasibility. In study the unit fixed cost of the energy produced from Co-generation plant is one third of the unit variable cost[fuel cost] and it seems better to select high thermal efficiency machine for Co-generation plant even with some higher cost of the plant.

  • PDF

A case study of extraplanar molecular gas in a Virgo spiral using the ALMA

  • Lee, Bumhyun;Chung, Aeree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.61.3-62
    • /
    • 2016
  • NGC 4522 is a spiral galaxy located in the Virgo cluster which appears to be undergoing active ram pressure stripping due to the intracluster medium (ICM). What makes this galaxy special is the extraplanar CO gas, some of which coincides with the extraplanar $H{\alpha}$ patches. As one of the few cases where the interstellar molecular gas is thought to have been pushed out from the stellar disk by the ICM, this galaxy provides an opportunity to study the impact of ICM pressure on the dense/star forming gas and its fate in the extraplanar space after stripping. In order to probe detailed molecular gas properties inside and outside the stellar disk and the associated star formation activities, we have observed NGC 4522 in 12CO (1-0) and 13CO (1-0) using the ALMA. We have targeted two regions, one around the center of the galaxy and one centered on the peak of the extraplanar CO, detecting both lines in both regions. Particularly, this is the first case where 13CO gas has been detected outside the stellar disk in a galaxy undergoing ram pressure stripping. In this work, we present preliminary results from the ALMA observations and discuss the evolution of molecular gas properties and star formation activities inside and outside the stellar disk.

  • PDF