• Title/Summary/Keyword: clothing insulation

Search Result 124, Processing Time 0.019 seconds

An Approach to Improve Thermal Insulation Properties and Fabric Hand of Wool and Wool-like Fabrics under High Molecular Polyethylene Glycol Treatment (고분자량 Polyethylene Glycol 처리에 따른 모직물과 유사모직물의 보온성과 태의 향상 방안 모색)

  • 조길수;이은주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.6
    • /
    • pp.1041-1050
    • /
    • 1997
  • This study was carried out to improve the thermal insulation properties of wool and wool- like fabrics by treating the fabrics with polyethylene glycol, to evaluate the fabric hand of PEG treated wool and wool-like fabrics and to grade up the fabric hand of the treated fabrics by treating with softening agents. Wool and wool-like fabrics were treated with high molecular PEG-8,000 by PDC. The thermal release/storage properties were measured on a DSC. Hand of specimens were evaluated by KES-FB system. The results were as follows; 1. PEG-treated fabrics showed thermal storage and thermal release properties by DSC and the heat contents were generally proportional to the add-ons. 2. PEG-treated fabrics showed higher Koshi and lower Numeri and Sofutosa values due to lower tensile energy and recovery and higher bending rigidity and shear stiffness as the add- ons increased. 3. PEG-treated fabrics showed much lower bending rigidity after softening agents treatment.

  • PDF

The Effects of Textiles for Thermal Insulation Value Using a Thermal Manikin (써멀 마네킹 착용실험에 의한 보온력에 미치는 의복소재의 영향)

  • Son Won-Kyo;Choi Jeong-Wha
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.12 s.142
    • /
    • pp.141-151
    • /
    • 1999
  • This study was carried out to examine the effects of textile materials for thermal insulation value using a thermal manikin. Cotton, polyester, wool, silk and rayon were selected as outer wears like blouses, skirts, slacks, and one-pieces. Acetate was chosen as a lining. Brief and long sleeve upper underwear(cotton) were chosen as the inner wears. The results were as follows; There were no significant differences among the materials in skirts and blouse-skirt suits by the thermal manikin. However blouses, slacks, one-pieces and blouse-slacks suits were showed the effects of materials. Blouse-slacks suits was showed the highest thermal insulation value and one-piece had the lowest thermal insulation value.

  • PDF

Studies on the Thermal Insulation Effect of Bedding ( I ) - Warmth Retaining Property of Filling Material - (이부자리의 보온력에 관한 연구( I ) -충전물의 보온성 -)

  • Lee Song-Ja;Sung Su-Kwang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.251-256
    • /
    • 1992
  • As a basic expriment to find out the thermal insulation effect of bedding KES-F7 was used to measure. The warmth retaining ratio of the six kinds of filling materials as cotton, wool , silk, down, cotton/polyester was measured, and the infleunce on the warmth retaining ratio of the warmth retaining ratio and humidity by the material was investigated. The results obtained are as follows: 1. The warmth retaining ratio of each filling material was shown to range from $70\%$ to $77\%$ . The warmth retaining ratio of each material preyed to be high in order down> polyester> cotton/polyester>cotton>silk>wool fiber. 2. The warmth retaining ratio of each filling material decreased with the inclose of the humidity The effective reduction rate by filling fiber's was high in order wool>cotton>cotton/polyester>silk>down>polyester material. 3. The warmth retaining ratio of each filling material was shown to be in counter-correlation with the humidity, and the correlation coefficient (r=0.94-0.98) proved to be highly signi-ficant.

  • PDF

Development of Firefighters' Personal Protective Clothing with Nomex Honeycomb Fabric and its Protective and Comfort Evaluation (노멕스 허니콤 구조 직물을 적용한 소방관용 특수방화복 개발 및 이의 보호 쾌적 성능평가)

  • Jung, Jae-Yeon;Ku, Ponjun;Kim, Do Hyung;Kwon, Min-Jae;Kang, Sungwook;Choi, Jeong-Yoon;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.21 no.5
    • /
    • pp.606-617
    • /
    • 2019
  • The present study newly developed a firefighters' protective jacket and pants using a Nomex honeycomb structured layer (HPC) in cases of being exposed to flashover or flameover. This study evaluated the protective and comfort functions of an HPC compared to the current KFI firefighters' protective clothing (FPC). The results are as follows. First, thermal protective performance (TPP) of fabric layers was 2.75 times greater for HPC than FPC at $125kW/m^2$. Second, the predicted second and third degree burn areas were smaller for HPC than FPC when using a flame manikin. Third, thermal insulation using a thermal manikin was 0.2 clo greater for HPC than FPC. Fourth, there were no marked differences in maximal performance, mobility, and microclimate temperature/humidity between FPC and HPC through human wear trials. The thermal insulation of HPC was higher than that of FPC; however, any negative effect of HPC thermal insulation on the comfort functions for firefighters was not found. In conclusion, the newly-developed HPC provided more protection in reducing burn injuries from $125kW/m^2$, while no negative impact on maximal performance, mobility and thermal comfort functions of firefighters, which is appropriate for quick-evasive tactics at the flashover, flameover or back draft fires.

A Study on Wearing Satisfaction and Thermal Properties of Jumper for Korean Military Tank Drivers (전차병 점퍼의 착용만족도 및 보온성에 관한 연구)

  • Kwon, Seo-Yoon;Choi, Eun-Mi;Lim, Chae-Guen;Shin, Dong-Woo;Kim, Kyung-Pil;Kwon, Oh-Kyung;Jeong, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.261-268
    • /
    • 2012
  • The purpose of this study is to investigate problems of design, fitness, suitability for movement, and wearing comfort of jumper for Korean military tank drivers through analysis of actual wearing condition by questionnaire and field evaluation and to provide basic data for developing its improved design. The survey was done for 477 military tank drivers and evaluation was performed using thermal manikin to measure insulation. The overall satisfaction for design of jumper for military tank driver was over 3.5(likert scale). The overall satisfaction for fitness of jumper for military tank driver was also over 3.5. The satisfactions for material was between 2.39 and 3.13 and the satisfaction for pilling property was the lowest, followed by static property and shape stability after laundering. The satisfactions for movement suitability were standing(3.81), sitting(3,38), raising hand(forward: 2.90, sideward: 3.01), respectively. In insulation evaluation of jumper for military tank drivers and outwears(jacket, jumper), the insulation of jumper for military tank drivers was lower than outwear(jumper) and same with outwear(jacket). The insulation in dynamic and still condition(without wind) of jumper for military tank driver was 0.37clo and 0.31clo, respectively. Its decreation rate in dynamic condition comparing to still condition was 59% which was lower than jacket(0.73clo) and jumper(1.15clo).

Comport Sensation of Blue Jeans depending on Fiber Contents (청바지의 소재별 쾌적감에 관한 연구)

  • 홍문경;이미식;권계화;전정애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.2
    • /
    • pp.237-248
    • /
    • 2001
  • The purpose of this study was to compare the comfort sensation depending on four different kinds of denim blue jeans: cotton, cotton/tencel, tencel, cotton/pp. The objective and subjective experiments were conducted to measure the comfort of blue jeans. To investigate the objective comfort, physical properties related to thermal insulation, moisture properties and hand were measured. For subjective comfort measurement, 5 healthy female college students were taken as subjects. The outcomes of the experiments are as follows: The higher the air permeability and bulk density of the denim, the lower the thermal insulation, the thicker the denim, the higher the thermal insulation. Tencel blending denim showed the higher bulk density, the lower air contents, and consequently the lower thermal insulation than the other denims. Tencel showed the highest moisture regain, and cotton/tencel blend showed the highest water vapor permeability. Tencel denim had relatively better flexibility, shape stability and elastic recovery than the other denims. The total hand values of the denims by KES-FB system were not significantly different. Cotton and cotton/pp denims raised the subjects body temperature after excercise more than tencel or cotton/tencel denims. Average skin temperature was found to have a correlation with micro climate temperature and micro climate humidity. The correlation coefficients were 0.749 and 0.767, respectively. However, average skin temperatures were not significantly different among the materials. Pulse rate was found to be the highest when wearing cotton/pp and the lowest in case of cotton/tencel denim. The energy was consumed in order of cotton>cotton/pp>tencel>cotton/tencel. There was no significant difference in preference before excercise, but, after the excercise, the order of preference changed as the following; cotton/tencel>tencel>cotton/pp>cotton.

  • PDF

Estimation of Standard Clothing Weight for Rural Residents in Their Indoor Living (농촌지역주민의 실내환경온도에 따른 표준착의량의 추정)

  • Jeong, Young Ok;Choi, Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.4
    • /
    • pp.518-528
    • /
    • 1993
  • The purposes of this study are to know the environmental conditions of rural houses, thermal sensation and clothing weight of rural residents and to estimate the standard clothing weight according to their indoor living temperature. In this study, the 631 rural residents of both sexes and all generations were selected from 5 rural districts of Kyunggi, Kangwon, Chungnam, Chonnam and Kyungbuk province and the surveys which include clothes, environmental conditions and thermal sensation carried out 4 times-once in each season-from July 1989 to April 1990. The results of this study are· as follows. 1. The ranges of outdoor temperature are $21{\sim}31^{\circ}C$ in summer, $7{\sim}20^{\circ}C$ in spring/autumn, $-15{\sim}5^{\circ}C$ in winter and those of indoor temperature are $24{\sim}31^{\circ}C$ in summer, $15{\sim}23^{\circ}C$ in spring/autumn, $11{\sim}17^{\circ}C$ in winter. The ranges of indoor temperature is within comfortable range in spring, summer and autumn but in winter it is below the range. 2. There is a negative relationship between indoor temperature and clothing weight(r = -0.927) and the simple regression equation is as follows. Y = -61.97X + 2048.44(Y : total clothing weight $g/m^2$, X : indoor temperature $^{\circ}C$). 3. There is no significant difference of clothing weight among the thermal sensation, so clothing insulation can not affect the thermal sensation. 4. Clothing weight of light-clothing-weight group is 70~75% of middle-clothing-weight group and clothing weight of heavy-clothing-weight group is 130% of middle-clothing-weight group. So the standard clothing weight for rural residents in their indoor living is estimated as Fig. 6.

  • PDF

Development of the Practical Garment Apparatus to Measure Vital Sign of ECG for U-Health Care (ECG 생체신호 측정을 위한 실용적 U-헬스케어 의복개발)

  • Park, Hye-Jun;Hong, Kyung-Hi;Kim, Seung-Hwan;Shin, Seung-Shul
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.292-299
    • /
    • 2007
  • Development of portable device measuring the vital sign continuously with no limit of time and space is absolutely prerequisite for the U-health care that grafts the ubiquitous concept into medical system. Accordingly, it requires to develop a garment style apparatus for measuring vital-sign that is easy to wear on for a long time period. This study suggests a method to improve the insulation of electric cable and the skin adhesion of electrode by integrating the electric conductive material to garment, in order to develop a garment apparatus for measuring ECG for U-health care. Results of the research are as follows; In order to provide the adjacent conductive yarns with insulation, braid with narrow woven end was interlaced using polyester yarn. As a result, the direct contact between electric conductive yarns was restrained, which would be interposed into pin-tuck structured cable. Washable silicone gel applied around the electrode made of electric conductive fabric improved the adhesion, which prevents electrodes from dropping off from the skin surface during body movement. ECG signals on the human subject were tested using the garment apparatus developed by the above method. And the result was that the clear QRS wave formation in the typical form of ECG could be measured in both conditions of still and moving state as well. The result of this study is expected to contribute for the production of U-health care related medical apparatus by accelerating the practical uses of the garment measuring vital sign at a reasonable price.

Far IR Emission and Thermal Properties of Ceramics Coated Nylon Fabrics (세라믹스 처리된 나일론 직물의 원적외선 방사성능과 보온효과)

  • Yeo, Suk-Yeong;Lee, Dong-Hwa;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.4
    • /
    • pp.515-524
    • /
    • 1998
  • The purpose of this study was to evaluate the thermal properties of ceramics coated nylon fabrics by determining far infra-red emissive properties, heat storage/release and thermal insulation. Far IR emissivity and emissive power were measured for 7~ 140n at 50'C . Three types of ceramics such as cordierite with $\alpha$-alumina, a-alumina with titanium oxide and a-alumina were chosen as specimens. Cordierite with $\alpha$-alumina was chosen to treat on the fabrics due to the good emissive properties on the fabrics. Add-ons and contents of ceramics were analyzed for ceramics and/or polyurethane coated fabrics. For the physical properties, thickness and air permeability were measured. Results showed a difference in the emissive property between ceramics themselves and ceramics coated fabrics. In the ambient temperature, there was no diffenence in emissivity among the different ceramics contents. Thermography showed that when the fabric was heated with the light, surface mean temperatures of fabrics were increased as the contents of ceramics increased, and the heat storage property was confirmed. In case of same thickness and air permeability, the thermal insulation value increased as the contents of ceramics increased because of increasing heat storage and Far IR reflectivity. So there were absorption and heat storage of ceramics for Far IR from human and reflection to human between ceramics coated fabrics and human.

  • PDF