• Title/Summary/Keyword: closed-loop

Search Result 2,023, Processing Time 0.027 seconds

Closed-Loop Timing Controller Design for Control Rod Drive Mechanism (CRDM) Control System in Pressurized Water Reactor

  • Kim, Byeong-Moon;Joon Lyou
    • Nuclear Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.167-174
    • /
    • 1997
  • The method that the operating condition of Control Rod Drive Mechanism (CRDM) can be monitored without mounting sensors within CRDM housing was developed, and by using this developed method the closed-loop controller for the CRDM was designed which can optimize the performance and maximize the reliability of CRDM operation. Neural network is utilized as pattern recognition engine in detecting CRDM actuation. In this paper, most problems in previous open loop system are resolved. The control algorithms for closed-loop system ore developed and implemented within the hardware of timing controller based on microprocessor. All functions in the timing controller ore verified by means of real time CRDM simulator. The results show that the timing controller performs its intended functions properly.

  • PDF

Feedback stabilization of linear systems with delay in control by receding horizon (지연요소를 갖는 시스템의 안정화 방법)

  • 권욱현
    • 전기의세계
    • /
    • v.28 no.5
    • /
    • pp.44-48
    • /
    • 1979
  • For ordinary systems the receding horizon method has beer proved by the author as a very useful and easy tool to find stable feedback controls. In this paper an open-loop optimal control which minimizes the control energy with a suitable upper limit and terminal control and state constraints is derived and then transformed to the closed-loop control. The stable feedback control law is obtained from the closed-loop control. The stable feedback control law is obtained from the closed-loop control by the receding horizon concept. It is shown by the Lyapunov method that the control law derived from the receding, horizon concept is asymtotically stable under the complete controllability condition. The stable feedback control which is similar to but more general than the receding horizon control is presented in this paper To the author's knowledge the control laws in this paper are easiest to stabilize systems with delay in control.

  • PDF

Development of 6 DOF Positioning Manipulator Using Closed Loop Structure and Its Kinematic Analysis (폐루프 구조를 가지는 6 자유도 머니퓰레이터의 개발 및 기구학적 해석)

  • 김경찬;우춘규;김수현;곽윤근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Parallel link manipulators have an ability of more precise positioning than serial open-loop manipulators. However. general parallel link manipulators have been restricted to the real applications since they have limited workspace due to interference among actuators. In this study, we suggest a closed-loop manipulator with 6 degrees-of-freedom and with enlarged workspace. It consists of two parts for minimizing the interference among actuators. One part is lower structure with planar 3 degrees-of-freedom and the other is upper one with spatial 3 degrees-of-freedom. Forward kinematics and inverse kinematics are solved, research about singularity points are carried out and workspace is evaluated. The comparison of workspace between Stewart platform, which is the typical parallel link manipulator, and the suggested manipulator shows that the workspace of the latter is wider than that of the former. Especially, simulation results also show that the suggested manipulator is more suitable when there needs rotation in the end-effector.

  • PDF

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

Design of a Triple-Mode Bandpass Filter Using a Closed Loop Resonator

  • Myung, Jae-Yoon;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.2
    • /
    • pp.86-90
    • /
    • 2017
  • In this study, a novel third-order bandpass filter, which is based on a rectangular closed loop resonator, is presented. By adding a series resonator to the conventional loop resonator, the resonator's even resonant mode is split into two modes, while the odd resonant mode is not affected. Therefore, by varying the values of the series resonator elements, the resonant frequencies of two even modes can be determined independent of the odd-mode resonant frequency. In the proposed triple-mode filter design, instead of using a lumped series resonator, a T-shaped transmission line is coupled to the resonator via a small gap. To verify the design method, a filter is designed at 2.4 GHz with a bandwidth of 100 MHz. The improved performances of the proposed triple-mode filter are compared with those of the conventional dual mode filter.

An offset algorithm with forward tracing of tangential circle for open and closed poly-line segment sequence curve (접원의 전방향 경로이동에 의한 오프셋 알고리즘)

  • Yun, Seong-Yong;Kim, Il-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.1022-1030
    • /
    • 2003
  • In this paper we propose a efficient offset curve construction algorithm for $C^0$-continuous Open and Closed 2D sequence curve with line segment in the plane. One of the most difficult problems of offset construction is the loop problem caused by the interference of offset curve segments. Prior work[1-10] eliminates the formation of local self-intersection loop before constructing a intermediate(or raw) offset curve, whereas the global self-intersection loop are detected and removed explicitly(such as a sweep algorithm[13]) after constructing a intermediate offset curve. we propose an algorithm which removes global as well as local intersection loop without making a intermediate offset curve by forward tracing of tangential circle. Offset of both open and closed poly-line segment sequence curve in the plane constructs using the proposed approach.

  • PDF

A study on the implementation of closed-loop system using the stepper motor back-EMF (스텝모터 역기전력을 이용한 폐루프 시스템 구현에 관한 연구)

  • Im, Sungbeen;Jeong, Sanghwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.3
    • /
    • pp.363-370
    • /
    • 2015
  • In this paper, the control technique of the stepping motor using back electromotive force(B-EMF) without encoder is investigated. The stepping motor generally uses the rotary encoder to detect the rotor position. Since this method increases the cost and the motor configuration size, the new closed-loop control method applied for the B-EMF was implemented by using current detect circuit, AD-converter, and micro controller unit(MCU). The control loop of stepping motor became very simplified. The current change of stepping motor measured by the amplifier was measured and analyzed, when the missing step is occurred. Based on the data from current feedback, position errors were compensated and confirmed by using AD-converter.

Controller Auto-tuning Scheme using System Monitoring inFrequency Domain (주파수역에서 시스템 감시를 이용한 제어기 Auto-tuning기법)

  • 정유철;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.136-139
    • /
    • 2000
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-Imp system; instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the conventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, experimental results of robot path-tracking control applied with various controllers is used, and then is analyzed with respect to a equivalent proportional controller. Experimental results and analytic results are well-matched.

  • PDF

An Experimental Study on the Performance of Semi-Closed Loop Ground Heat Exchanger (반밀폐형 지중열교환기 성능에 관한 실험적 연구)

  • Kim, Ook-Joong;Yeom, Han-Kil;Lee, Chun-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.542-545
    • /
    • 2007
  • A semi-closed loop ground heat exchanger is proposed and its performance is compared through the measuring the effective thermal conductivity of the ground. In-situ tests based on the line source model are carried out to evaluate the thermal characteristics of each ground heat exchanger which has different penetration water flow rate. The test results show the increasing effective thermal conductivity of ground as the penetration water flow rate(PWFR) is increased. Therefore, the higher thermal performance of the proposed semi-closed ground heat exchanger can be expected.

  • PDF

Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop (파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF