• Title/Summary/Keyword: closed-loop

Search Result 2,023, Processing Time 0.028 seconds

Robustness of Independent Modal Space Control for Parameter and Modal Filter Errors (파라메터오차 및 모달필터오차에 대한 독립모달공간 제어기법의 강인성 해석)

  • Hwang, Jai-Hyuk;Kim, Joon-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3549-3559
    • /
    • 1996
  • In this study, the effect of parameter and modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC ( Independent Modal Space Control). If the control force is designed on the basis of the mathematical model with the parameter and modal filter errors, the closed-loop performance of the vibration control system will be degraded depending on the magnitude of the errors. An asymptotic stability condition of the system with parameter and modal filter errors has more significant effect on the stability condition of the system with parameter and modal filter errors has been drived using Lyapunov approach. It has been found that modal filter error has more significant effect on the stability of closed-loop system than parameter error does. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator thchniques.

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Partial Miscibility of Binary Solution with Specific Interaction of Binomial Distribution (이항분포의 특정 상호작용을 갖는 이성분 용액에서의 부분혼합도)

  • Jung, Hae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.6
    • /
    • pp.528-534
    • /
    • 2014
  • In some binary solution, closed miscibility loop of temperature-composition phase diagram occurs where both an upper critical solution temperature and a lower critical solution temperature exist. It is known that this phenomena occurs if specific interaction between molecules exists. There are several ways describing the specific interaction. In this work it is assumed that the total number of specific interactions is distributed according to binomial distribution. In this case, exact mathematical conditions for closed miscibility loop phase behavior are derived when the specific interaction is applied to regular solution theory, quasichemical theory and Flory-Huggins lattice theory. And we investigated the effect of parameters on the phase diagram. The phase diagram of water-nicotine is calculated and compared with experimental data.

Creation and Use of Process oriented Knowledge for Effective FRACAS (효과적인 FRACAS 운용을 위한프로세스 지식의 생성과 활용)

  • Lee, Jae-Hoon;Yoo, Ki-Hoon;Kim, Ki-Young;Seol, Dong-Jin;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.8 no.3
    • /
    • pp.113-124
    • /
    • 2008
  • In reliability engineering, failure reporting, analysis, and corrective action system (FRACAS) is an useful tool for effective failure reporting and related operations. FRACAS is generally mainly focused on implementation of its closed-loop process, but also includes various related information which has to be effectively managed such as failure types, failure modes, failure mechanisms, and corrective actions. In this study, we adopt and utilize the concept of process knowledge, and create it through abstraction of FRACAS information. At each step of closed-loop process, the necessary type of knowledge, priority and usability are clearly defined. This study also suggests corresponding management tools such as business process management system, knowledge management system, and their key elements and functions to deal with process knowledge. A prototype system using simple closed-loop process with its process knowledge is presented to demonstrate the feasibility of the proposed work.

  • PDF

A Study on Entering Water Temperature in Vertical Closed Ground Loop System Considering the Economical Feasibility in Load of the Office Building (사무시설에 수직형 지열원 냉 난방시스템의 경제성을 고려한 인입온도(EWT)에 관한 연구)

  • Lee, Byung-Doo;Lee, Dae-Woo;Lee, Se-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.579-585
    • /
    • 2009
  • Recently, Vertical-Closed Loop system using geothermal which is the most efficient among the building cooling and heating systems is coming into wide spread due to assistance of domestic policies. However, there is a limitation that a design of ground heat exchanger taking 60% of construction cost is done by GLD and GLHEPRO programs without specific guidelines and consideration on Entering Water Temperature(EWT). For getting an optimal EWT, we analyzed the costs for construction of ground heat exchanger and cooling and heating for 15 years. In the results, reduction of construction costs as the length of ground heat exchanger shortens was much greater than increase of the electrical power consumption as COP gets low. EWT that COP of heat pump can be 3.76 or above was below $31^{\circ}C$ in cooling and was over $5^{\circ}C$ in heating.

  • PDF

Design of the Discrete Compensator for Arbitrary Steady-State Response Using the Effects of Zero Location in Second-Order Discrete Systems (이차 이산 시스템에서 영점의 위치의 영향을 이용한 임의의 정상상태 응답을 위한 이산 보상저의 설계)

  • Lee, Jae-Seok;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.382-386
    • /
    • 2002
  • The damping ratio $\zeta$ of the unit-step response of a second-order discrete system is a function of only the location of the closed-loop poles and is not directly related to the location of the system zero. However, the peak overshoot of the response is the function of both the damping ratio $\zeta$ and an angle $\alpha$, which is the phasor angle of the damped sinusoidal response and is determined by the relative location of the zero with respect to the closed-loop poles. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is considered as a function of the angle $\alpha$ or the system zero location. In this paper the effects of the relative location of the zero on the system performance of a second-order discrete system is studied, and a design method of digital compensator which achieves arbitrary steady-state response with minimum peak overshoot while maintaining the desired system mode and the damping ratio of the unit step response is presented.

  • PDF

Study on Automatic Mixing of Nutrient Solution Using ion Electrodes for Closed-Loop Hydroponics (이온전극을 이용한 순환식 양액 자동 조제에 관한 연구)

  • 김민규;류관희;장유섭;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.425-432
    • /
    • 2002
  • This study was carried out to develop an automatic mixing system of nutrient solution for closed-loop hydroponics using ion electrodes. The results of the study are summarized as follows: 1. It appeared that ion-electrodes had not to be soaked into nutrient solution for a long time since it was much less durable than EC or PH sensors. Once ion-electrodes were soaked into real nutrient solution for a long time, they became unstable. 2. ion measurement modules, which were able to sample recirculated nutrient solution and easily wash and dry ion-electrodes, were developed in order to use ion-electrodes continuously. 3. The results of calibration tests on three kinds of ion electrodes presented that the time required to read measurement data was over 30 seconds. Using the calibration data the regression equations for the ion electrodes were developed. 4. An automatic nutrient-solution mixing system using the three kinds of ion electrodes was developed and then its accuracy was examined. The control errors of the mixing system using ion electrodes were in the range of 9.8 to 12%.

The New Generation of Hydraulic Presses-Progress in the Forming Process

  • Prommer, Eric
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1276-1277
    • /
    • 2006
  • The ever increasing requirements on today's compacts with regard to their geometry and precision call for flexible high-precision and most capable production systems. DORST Technologies has coped with these requirements by developing the new HP series for pressing forces between 1600 kN and 16000 kN and the new HS series for pressing forces between 150 kN and 1200 kN. These fully hydraulic presses featuring upper ram, lower ram, core rod, filler, up to 4 lower tool levels and up to 4 upper tool levels with closed-loop controlled movements. Thanks to latest servo technology and an electronic bus system it is possible to have all movements closed-loop controlled in the desired relation to each other. Thus, today's hydraulic presses provide high stroke rates, low energy consumption and a user-friendly interface. The input of data is carried out via clearly arranged screen masks on a touch-screen. The innovative DORST $IPG^{(R)}$ (Intelligent Program Generator) has been designed to support the set-up staff in preparing and optimizing the toolprogram. The combination of the machine type with the hydraulic unit determines the productivity in consideration of the specific application and the part to be pressed. Thanks to the closed-loop control circuits, DORST hydraulic automatic presses of the latest generation ensure unmatched precision and repeatability - and consequently process reliability - often without necessitating subsequent machining steps.

  • PDF

Gain Optimization of Kinematic Control for Wire-driven Surgical Robot with Layered Joint Structure Considering Actuation Velocity Bound (와이어로 구동하는 적층형 다관절 구조를 지닌 수술 로봇의 구동 속도를 고려한 기구학적 제어기의 게인 최적화)

  • Jin, Sangrok;Han, Seokyoung
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.3
    • /
    • pp.212-220
    • /
    • 2020
  • This paper deals with a strategy of gain optimization for the kinematic control algorithm of a wire-driven surgical robot. The proposed controller consists of the closed-loop inverse kinematics with the back-calculation method. The closed-loop inverse kinematics has 18 PID control gains, and the back-calculation method has 6 gains. An efficient strategy is designed to optimize 18 values first and then the remaining 6 values. The optimal gain sets are searched under the step input with performance indices. In this gain optimization, the objective function is defined as the minimum value of signal-to-noise ratio of the performance indices for 6 DoF (Degree-of-Freedom) motion that is based on the Taguchi method, and the constraints are applied to obtain stable responses for each motion evenly. The gain sets obtained are verified by simulations using the test trajectories. In comparative results, the optimal gain value based on the performance index combined with ISE (integral of square error) and settling time showed the best control performance.

A design of neuro-fuzzy adaptive controller using a reference model following function (기준 모델 추종 기능을 이용한 뉴로-퍼지 적응 제어기 설계)

  • Lee, Young-Seog;Ryoo, Dong-Wan;Seo, Bo-Hyeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 1998
  • This paper presents an adaptive fuzzy controller using an neural network and adaptation algorithm. Reference-model following neuro-fuzzy controller(RMFNFC) is invesgated in order to overcome the difficulty of rule selecting and defects of the membership function in the general fuzzy logic controller(FLC). RMFNFC is developed to tune various parameter of the fuzzy controller which is used for the discrete nonlinear system control. RMFNFC is trained with the identification information and control closed loop error. A closed loop error is used for design criteria of a fuzzy controller which characterizes and quantize the control performance required in the overall control system. A control system is trained up the controller with the variation of the system obtained from the identifier and closed loop error. Numerical examples are presented to control of the discrete nonlinear system. Simulation results show the effectiveness of the proposed controller.

  • PDF