• 제목/요약/키워드: closed system

검색결과 3,490건 처리시간 0.031초

전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구 (Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

폐교시설의 활용모형 개발을 위한 예비 분류체계 도출 연구 - 선행연구와 공공 디자인지표의 비교를 중심으로 - (A Study on the Preliminary Classification System for the Development of the Application Model of Closed School Facilities - Focused on the Comparison of Public Design Indicators with Pre-research -)

  • 김재영;이종국
    • 청소년시설환경
    • /
    • 제17권1호
    • /
    • pp.131-141
    • /
    • 2019
  • The purpose of this study is to derive and type utilization indexes by comparing public design indicators with preceding studies related to closed school facilities, and to derive preliminary classification systems through a correlation review between indicators. Pre-research was conducted in the scope of academic papers, academic journals, research reports, and special act for promoting the utilization of closed school assets. Public design indicators were set in the scope of domestic design guidelines, the Seoul city public design assessment system, the 'Good Building' designation system, and the UK Design Quality Index (DQI). and the design review of the British architects. First of all, the research method looked at laws, procedures and utilization of closed schools, and reviewed the preceding study and domestic and international public design indicators sequentially. Next, the association was reviewed through a comparison between the preceding study and the public design indicators, and a preliminary classification system for the use of closed schools was derived from this.

한국과 일본의 농촌지역 폐교활용 정책 비교 (A Comparative Study on the Utilization Policy for Closed Schools in Korea and Japan)

  • 김홍기
    • 한국농촌건축학회논문집
    • /
    • 제19권3호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, the number of closed rural schools is increasing due to the decrease in school age population. This study aims to comparative analysis of utilization policies for closed schools in Korea and Japan. The results are as follows. First, Both Korea and Japan was expected to increase the number of closed schools since the standard of abolition of small schools has been strengthened. Second, In Korea, it was possible to know the detailed information of closed schools through 'Eduinfo' website, but it was hard to know the detailed information of utilization cases of closed schools. On the other hand, Japan not only provided information about the unused school facilities but also introduced the utilization cases of closed schools and financial support system for utilization of closed school. It was characterized by linking with the information of unused schools and company, NPO, elderly welfare facility, etc. Third, In korea Superintendent established plans to use closed schools to respond flexibly to local circumstances. Japan simplified the procedures for closed schools to promote the utilization of closed schools. Finally, In Japan, there was various financial support system. But in Korea, it supported the cost of subsidy reduction, free loan, maintenance and management and operation.

비구조적인 불확실성을 가지는 시스템에 대한 반복 제어기의 설계 (Design of a repetitive controller for the system with unstructured uncertainty)

  • 도태용;문정호;정명진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.779-782
    • /
    • 1996
  • Repetitive control is a proposed control strategy in view of the internal model principle and achieves a high accuracy asymptotic tracking property by implementing a model that generates the periodic signals of period into the closed-loop system. Since the repetitive control system contains a periodic signal generator with positive feedback loop, which reduces the stability margin, in the overall closed-loop system, the stability of the closed-loop system should be considered as an important problem. In case that a real system has plant uncertainties which are not represented through modeling, the robust stability problem of the repetitive control system has not been considered sufficiently. In this paper, we propose the robust stability condition for the system with modeling uncertainty. The proposed robust stability condition will be obtained using the robust performance condition in the H$_{\infty}$ control. Moreover, by use of the proposed robust stability condition, we propose a procedure that designs a repetitive controller and a feedback controller simultaneously which can stabilize the overall closed-loop system robustly and which can also do the closedloop system without repetitive controller..

  • PDF

지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구 (Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System)

  • 송재용;이근춘;박남서
    • 대한건축학회논문집:구조계
    • /
    • 제34권5호
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

The Function Discovery of Closed Curve using a Bug Type of Artificial Life

  • Adachi, Shintaro;Yamashita, Kazuki;Serikawa, Seiichi;Shimomura, Teruo
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.90-93
    • /
    • 2003
  • The function, which represents the closed curve, is found from the sampling data by S-System in this study. Two methods are proposed. One is the extension of S-System. The data x and y are regarded as input data, and the data z=0 as output data. To avoid the trap into the invalid function, the judgment points (x$\_$j/, y/sug j/) are introduced. They are arranged in the inside and the outside of the closed curve. By introducing this concept, the functions representing closed curve are found by S-System. This method is simple because of a little extension of S-System. It is, however, difficult for the method to find the complex function like a hand-written curve. Then another method is also proposed. It uses the system incorporating the argument function. The closed curve can be expressed by the argument function. The relatively complex function, which represents the closed curve like a hand-written curve, is found by utilizing argument function.

  • PDF

주파수역에서의 피드백시스템의 성능향상을 위한 제어기 Atuo-tuning 기법 (Controller Auto-tuning Scheme for Improving Feedback System Performance in Frequency Domain)

  • 정유철;이건복
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.26-30
    • /
    • 2001
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the con-ventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF

주파수역에서 시스템 감시를 이용한 제어기 Auto-tuning기법 (Controller Auto-tuning Scheme using System Monitoring inFrequency Domain)

  • 정유철;이건복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.136-139
    • /
    • 2000
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-Imp system; instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the conventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, experimental results of robot path-tracking control applied with various controllers is used, and then is analyzed with respect to a equivalent proportional controller. Experimental results and analytic results are well-matched.

  • PDF

폐교를 활용한 노인요양시설 리모델링 사례와 평면유형 개발 -옥천군 동이면 동이중학교를 대상으로- (A Case Study on the Remodeling Plan of Closed School as Elderly Facility And Developing Composition Type -Implication of Okchun Dongyi Middle School-)

  • 남윤철
    • 한국농촌건축학회논문집
    • /
    • 제13권4호
    • /
    • pp.99-106
    • /
    • 2011
  • Since 1982, schools have been closed down by urbanization in rural areas. 3,386 schools had been closed down by March 2010. The average 300 schools was closed down every year. 55.7% closed schools were sold, 14.5% closed schools were rented. 6.3% closed schools have been utilized as education facilities. First, the closed school should be utilized as education facilities. And it should be utilized as public facilities as well as welfare facilities for local residents. This paper presents a case of the welfare facility remodeled using Don-Yi middle school in Okcheon-Gun, Chungcheongbuk-Do and propose the unit care composition. The main contents is composed of posts, beams floors, stairs. Masonry infill walls and windows ware improved. Corridors were placed. A classroom were divided into 2 rooms with the Korean traditional heating system(on-dol) for four. Other conveniences were designed for a cafeteria, recreation, a restroom as space required. It is effective to utilize the closed school that has magnificent views and orientation, space construction. The Unit-care system is proposed by 4 types developments.