• Title/Summary/Keyword: clipping

Search Result 480, Processing Time 0.022 seconds

Determination of Aneurysmal Location with 3 Dimension-Computed Tomographic Angiography in the Microsurgery of Paraclinoid Aneurysms

  • Kim, Min-Young;Chung, Seung-Young;Kim, Seung-Min;Park, Moon-Sun;Jung, Sung-Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Objective : Determining the location of paraclinoid aneurysms for microsurgery is important for selecting treatment options, especially when deciding on the release of the dural ring in direct clipping. We examined the reliability of using the optic strut as an anatomical landmark for evaluating the location of paraclinoid aneurysms. Methods : Cadaveric dissection was performed to establish the relationship of the optic strut to the dural ring. Results from these anatomic studies were compared with the three-demensional computed tomographic angiographic [3D-CTA] findings of nine patients with ten paraclinoid aneurysms between May 2004 and October 2005. These, 3D-CTA results were then compared with intraoperative findings. Results : The inferior boundary of the optic strut accurately localized the point at the proximal dural ring in cadaveric study. The optic strut and its relationship to the aneurysms was well observed on the multiplanar reformats of 3D-CTA. During microsurgery, nine of ten aneurysms were verified to arise from distal to the upper surface of the optic strut. Two aneurysms that had arisen between the inferior and superior boundary of the optic strut were observed to lie within the carotid cave. One aneurysm which had arisen at the inferior boundary of the optic strut and directed inferiorly was observed to lie within the cavernous sinus just after the release of the proximal ring. Conclusion : The optic strut, as identified with multiplanar reformats of 3D-CTA, provided a reliable anatomic landmark for the proximal rings and an important information about the location of aneurysms around the anterior clinoid process (ACP). Therefore, 3D-CTA and the optic strut could become an invaluable tool and a landmark in the assessment of the location of paraclinoid aneurysms for microsurgery.

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

Surgical Flow Alteration for the Treatment of Intracranial Aneurysms That Are Unclippable, Untrappable, and Uncoilable

  • Lee, Sung Ho;Ahn, Jae Sung;Kwun, Byung Duk;Park, Wonhyoung;Park, Jung Cheol;Roh, Sung Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.518-527
    • /
    • 2015
  • Objective : The treatment of complex intracranial aneurysms remains challenging. One approach is the application of surgical flow alteration to treat aneurysms that are neither clippable, trappable, or coilable. The efficacy and limitations of surgical flow alteration have not yet been established. Methods : Cases of complex aneurysms treated with surgical flow alteration (proximal occlusion with or without bypass, distal occlusion with or without bypass and bypass only) were included in this retrospective study. Results : Among a total of 16 cases, there were 7 giant aneurysms (${\geq}25mm$ diameter) and 9 large aneurysms (>10 mm diameter); 15 of 16 aneurysms were unruptured. There were 8 aneurysms located in the anterior circulation, while the other 8 were in the posterior circulation. Aneurysms were treated with proximal occlusion in 10 cases and distal occlusion in 5 cases; in 1 case, the aneurysm occluded spontaneously after bypass without parent artery occlusion. All but 2 cases underwent prior or concurrent bypass surgery. Complete obliteration of the aneurysm at the latest imaging follow-up was shown in 12 of 16 cases (75.0%). Bypass patency was confirmed in 13 of 15 cases (86.7%). Surgery-related morbidity developed in 3 cases (18.8%, Glasgow outcome scale of 4) and all were perforator infarctions. There were no mortalities. Conclusion : Surgical flow alteration resulted in a high rate of aneurysmal obliteration with acceptable morbidity. Although several limitations remained, it could represent an alternative method for treating complex aneurysms.

Endoscopic Fluorescence Angiography with Indocyanine Green : A Preclinical Study in the Swine

  • Cho, Won-Sang;Kim, Jeong Eun;Kim, Sae Hoon;Kim, Hee Chan;Kang, Uk;Lee, Dae-Sic
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.513-517
    • /
    • 2015
  • Objective : Microscopic indocyanine green (ICG) angiography is useful for identifying the completeness of aneurysm clipping and the preservation of parent arteries and small perforators. Neuroendoscopy is helpful for visualizing structures beyond the straight line of the microscopic view. We evaluated our prototype of endoscopic ICG fluorescence angiography in swine, which we developed in order to combine the merits of microscopic ICG angiography and endoscopy. Methods : Our endoscopic ICG system consists of a camera, a light source, a display and software. This system can simultaneously display real-time visible and near infrared fluorescence imaging on the same monitor. A commercially available endoscope was used, which was 4 mm in diameter and had an angle of $30^{\circ}$. A male crossbred swine was used. Results : Under general anesthesia, a small craniotomy was performed and the brain surface of the swine was exposed. ICG was injected via the ear vein with a bolus dose of 0.3 mg/kg. Visible and ICG fluorescence images of cortical vessels were simultaneously observed on the display monitor at high resolution. The real-time merging of the visible and fluorescent images corresponded well. Conclusion : Simultaneous visible color and ICG fluorescent imaging of the cortical vessels in the swine brain was satisfactory. Technical improvement and clinical implication are expected.

The Meaning of the Prognostic Factors in Ruptured Middle Cerebral Artery Aneurysm with Intracerebral Hemorrhage

  • Oh, Ji-Woong;Lee, Ji-Yong;Lee, Myeong-Sub;Jung, Hyen-Ho;Whang, Kum;Brain Research Group, Brain Research Group
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.2
    • /
    • pp.80-84
    • /
    • 2012
  • Objective : This study analyzed the relationship between prognosis and multiple clinical factors of ruptured middle cerebral artery (MCA) aneurysm with intracerebral hemorrhage (ICH), to aid in predicting the results of surgical treatment. Methods : Enrolled subjects were 41 patients with ruptured MCA aneurysm with ICH who were treated with surgical clipping. Clinical factors such as gender, age, and initial Glasgow coma scale were assessed while radiological factors such as the volume and location of hematoma, the degree of a midline shift, and aneurysm size were considered retrospectively. Prognosis was evaluated postoperatively by Glasgow outcome scale. Results : Age and prognosis were correlated only in the groups with ICH over 31 mL or ICH at the frontal lobe or sylvian fissure. When initial mental status was good, only patients with ICH on the temporal lobe had a better prognosis. If the midline shift was less than 4.5 mm, the probability of better prognosis was 95.5% (21 of 22). If the midline shift was more than 4.5 mm, the probability of poor prognosis was 42.1% (8 of 19). Patients with ICH less than 31 mL had higher survival rates, whereas if the ICH was more than 31 mL, 41.2% (7 of 17) had a poor clinical pathway. Conclusion : Even if the initial clinical condition of the patient was not promising, by carefully examining and taking into account all factors, neurosurgeons can confidently recommend surgical treatment for these patients.

Surgical Results of Unruptured Intracranial Aneurysms

  • Kim, Sung-Ho;Choi, Byung-Yon;Chang, Chul-Hoon;Kim, Sang-Woo;Kim, Seong-Ho;Cho, Soo-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.2
    • /
    • pp.99-102
    • /
    • 2006
  • Objective : To document surgical mortality and morbidity for the treatment of unruptured intracranial aneurysms, and to identify optimal treatment modalities, the authors reviewed and analyzed the surgical results. Methods : The authors reviewed 49 cases of unruptured intracranial aneurysm without a previous history of subarachnoid hemorrhage from March 1984 through December 2003. Unruptured intracranial aneurysms were categorized as asymptomatic and symptomatic, and operative results were assessed using the Karnofsky scale at 3 months postoperatively. Outcomes were defined as 'excellent' for a Karnofsky scale score of 100, 'good' for a score of $80{\sim}90$, 'fair' for $50{\sim}70$, 'poor' for $10{\sim}40$, or as 'death'. Excellent and good results were defined as a 'favorable' outcome and others as 'unfavorable' outcome. Results : Of the 49 study subjects, 45 had a favorable outcome and 4 an unfavorable outcome. Surgical mortality was 6.1% and surgical morbidity was 2.0% for all subjects. And the symptomatic group had more complications. Conclusion : There were no significant relationships between aneurysmal size, location, and preoperative symptoms with surgical results. And we believe that the reasons for morbidity and mortality are attributable to strokes, thus more attention should be paid to peri- and post-operative patients care with a focus on strokes prevention in the symptomatic group.

Clinical and Radiogical Outcomes of Endovascular Detachable Coil Embolization in Paraclinoid Aneurysms : A 10-Year Experience

  • Jin, Sung-Chul;Kwon, Do-Hoon;Ahn, Jae-Sung;Kwun, Byung-Duk;Song, Young;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective : Direct surgical clipping of paraclinoid aneurysms poses technical challenges to even very experienced neurosurgeons, making endovascular treatment an alternative treatment modality in many centers. We have therefore retrospectively evaluated the safety and efficacy of endovascular detachable coil embolization of paraclinoid aneurysms. Methods : From June 1997 to June 2007, 65 patients underwent endovascular detachable coiling for 67 paraclinoid aneurysms (of which 9 were ruptured and 58 were unruptured) in our institute. Their medical records, radiological images and readings, and operation records were reviewed retrospectively. Results : After the initial embolization procedure, complete occlusion was achieved in 29 (43.3%) of the aneurysms treated by endovascular detachable coiling. Six aneurysms required retreatment, with two each requiring one, two, or three additional endovascular procedures. Fifty-five (82.1%) aneurysms were measured by three-dimensional time of flight (TOF) magnetic resonance images (MRI) or transfemoral cerebral angiography (TFCA) at a mean follow-up of 29.7 months (range from 4 to 94 months), with 39 aneurysms (70.9%) showing complete occlusion. Thromboembolic events (3.8%) were the most frequent complication. Rupture did not occur during or after any of the procedures. According to the Glasgow Outcome Scale (GOS), 98.4% of the patients treated by coil embolization had a score of 4 or 5. Conclusion : Our results indicate that endovascular detachable coiling is a safe and effective treatment modality in paraclinoid aneurysms.

The Avoidance of Microsurgical Complications in the Extradural Anterior Clinoidectomy to Paraclinoid Aneurysms

  • Son, Hee-Eon;Park, Moon-Sun;Kim, Seong-Min;Jung, Sung-Sam;Park, Ki-Seok;Chung, Seung-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.199-206
    • /
    • 2010
  • Objective : Paraclinoid segment internal carotid artery (ICA) aneurysms have historically been a technical challenge for neurovascular surgeons. The development of microsurgical approach, advances in surgical techniques, and endovascular procedures have improved the outcome for paraclinoid aneurysms. However, many authors have reported high complication rates from microsurgical treatments. Therefore, the present study reviews the microsurgical complications of the extradural anterior clinoidectomy for treating paraclinoid aneurysms and investigates the prevention and management of observed complications. Methods : Between January 2004 and April 2008, 22 patients with 24 paraclinoid aneurysms underwent microsurgical direct clipping by a cerebrovascular team at a regional neurosurgical center. Microsurgery was performed via an ipsilateral pterional approach with extradural anterior clinoidectomy. We retrospectively reviewed patients' medical charts, office records, radiographic studies, and operative records. Results : In our series, the clinical outcomes after an ipsilateral pterional approach with extradural anterior clinoidectomy for paraclinoid aneurysms were excellent or good (Glasgows Outcome Scale : GOS 5 or 4) in 87.5% of cases. The microsurgical complications related directly to the extradural anterior clinoidectomy included transient cranial nerve palsy (6), cerebrospinal fluid leak (1), worsened change in vision (1), unplanned ICA occlusion (1), and epidural hematoma (1). Only one of the complications resulted in permanent morbidity (4.2%), and none resulted in death. Conclusion : Although surgical complications are still reported to occur more frequently for the treatment of paraclinoid aneurysms, the permanent morbidity and mortality resulting from a extradural anterior clinoidectomy in our series were lower than previously reported. Precise anatomical knowledge combined with several microsurgical tactics can help to achieve good outcomes with minimal complications.

Biomass and Energy Content of Pinus koraiensis Stand Planted in Mt. Wolak (월악산 24년생 잣나무 인공림의 바이오매스와 에너지량)

  • Kwon, Ki-Cheol;Lee, Don Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.66-75
    • /
    • 2006
  • This study was conducted to understand the biomass and the energy content of 24-year-old Pinus koraiensis stand planted in Mt. Wolak, Chungcheongbuk-do, Korea. Nine sample trees were selected and harvested for the study. Stem, bark, branches and leaves were weighed respectively with the stratified clipping method, and analyzed for productive structure. The allometric regression equations between dry weight of each component and $D^2H$ were obtained to estimate the total biomass of aboveground (47.0 ton/ha) and other parts (56.5% from stemwood, 9.1% from stembark, 0.5% from current twigs, 18.4% from live branches, 2.6% from current leaves, and 12.9% from previous leaves). Annual net production of aboveground was 6.0 ton/ha/yr, and the ratios of stemwood, stembark, current twigs, live branches, and current leaves to that of aboveground were 49.8%, 7.3%, 3.5%, 18.6%, and 20.8%, respectively. Energy content of aboveground was 1,028 GJ/ha, and annual energy content was 133 GJ/ha/yr. Leaf area index (LAI) of P. koraiensis plantation was 20.2 in Mt. Wolak.

DCT Based Watermarking Technique Using Region of Interest (관심영역을 이용한 DCT기반 워터마킹 기법)

  • Shin, Jae-Wook;Jeong, Dong-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.1
    • /
    • pp.16-26
    • /
    • 2000
  • The proposed method inserts a watermark information not mto a whole Image region but only into regions of interest(ROIs) To extract the ROIs, we divide an original Image into sub-blocks and use modified Shi-Kuo Chang's PIM(picture information measure) as the criteria to select the ROIs Considering the directional information and frequency bands, we insert the watermark information into sub-blocks m the DCT domain. The proposed method can reduce the distortion in comparison With the other methods which utilize the whole Image as an nor The proposed method makes much less damaged Images m comparison to the other methods And those Images processed by the proposed algorithm are more robust to the changes caused by signal processing operations such as resampling, clipping. noise, and so on Also due to the block-based watermark insertion, the proposed method has the robustness to the Image compression processes such as JPEG and MPEG.

  • PDF