• Title/Summary/Keyword: clinical breast examination

Search Result 117, Processing Time 0.028 seconds

A Study on Need Assessment in Health Promotion Programs for Developing Nursing Centers - Breast Self Examination- (간호센타 개발을 위한 건강증진 프로그램 요구사정 연구-유방자가검진 프로그램을 중심으로-)

  • Park, In-Hyae;Kang, Hae-Young;Lee, Jeong-Hee;Ryu, Hyun-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.21-36
    • /
    • 2000
  • The purpose of this study was to assess the needs of breast self examination education (BSEE) programs for developing nursing centers. A first, we reviewed the literature of activity and management-related factors of nursing centers: and, second. we used a questionnaire to discover the degree of knowledge, attitude, and practice on breast cancer, as well as an individual's intention to participate BSEE program. 1. Reviewing the literatures of nursing center activities. Nursing centers which were administered by a professional nurse are an ideal site for faculty and student practices. With the use of nursing models of health. professional nurses in nursing centers diagnose and treat human responses to potential and actual health problems and offer holistic, client-centered health service. In nursing centers professional nursing services include health education, health promotion, and health-related research. A nursing center is comprised of the advisory and exacutive commitee; the advisory commitee serves consultants and links community needs to the nursing center, while the director of the exacutive commitee identifies the potential resources to generate funds, support, and facilitate the activities of staffs in a nursing center. Nursing centers mobilize various financal resources for reimbursement of services from college and insurance companies, collect minimum service fees from the client, and further collect fees for providing programs to community groups, this also includes membership fees, and donations. The services provided by nursing centers focus on services related to primary prevention, health maintenance & health promotion, direct nursing care for acute & chronic diseases, and holistic care for actual and potential health problems. The client satisfaction for the services was high. Students also showed positive reponses for their clinical experiences and independent working conditions. 2. The degree of knowledge, attitudes, and practices for breast cancer. and an individual's intention to participate in the BSEE program. The subjects of this study were 308 females in K-city in the Republic of Korea. Data were collected using a self-administered questionnaire. The mean age of the respondents was 35.0 years old. Those who already participated in the BSEE were 64.9%, and those who had support and encouragement to practice BSE from significant others were 25.1 %. Clients intent to participate in the BSEE were 37.0%. The mean score of knowledge(2.4 out of 5 points) and practices(1.8 out of 5 points) for breast cancer were quite low, but the mean score of attitudes was relatively positive04.5 out of 20 point) for breast cancer. Those who already had BSEE showed significantly high scores in knowledge(t=6.48, p<0.01), attitudes (t=10.54, p<0.01). and practices(t=57.07, p<0.001) for breast cancer than those who had not participated in the BSEE. In all age groups no intention to participate in the BSEE was higher than who the intention to participate. These findings suggest some strategies should be developed to increase the awareness of breast cancer's early detection.

  • PDF

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

Lack of Prognostic Value of Mean Corpuscular Volume with Capecitabine Therapy in Metastatic Breast Cancer

  • Bozkurt, Oktay;Berk, Veli;Kaplan, Muhammed Ali;Cetin, Bulent;Ozaslan, Ersin;Karaca, Halit;Inanc, Mevlude;Duran, Ayse Ocak;Ozkan, Metin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2501-2504
    • /
    • 2014
  • Background: Capecitabine is an oral fluoropyrimidine derivative which is frequently used alone or in combination regimens for the treatment of metastatic breast cancer. Although overall and progression free survivals have increased in recent years with the use of new generation drugs, predictive factors that would further improve the outcomes are needed. Previous studies have demonstrated the relation between post-treatment increase in mean corpuscular volume (MCV) and predicting therapy response as well as survival. The present study investigated the clinical impact of MCV elevation in metastatic breast cancer patients treated with capecitabine. Materials and Methods: The data of a total of 82 patients from three centers followed between June 2005 and June 2013 were retrospectively analyzed. The demographic data and hormone receptor status of the patients, as well as initial examination before and after treatment and data concerning progression were recorded. MCV ${\geq}100$ fl was considered as macrocytosis. Capecitabine was given at a dose of $2500mg/m^2$ daily for 14 days every three weeks. Pre-treatment and post-treatment MCV and other parameters of complete blood count were recorded. Post-treatment initial evaluation was performed after 2 cycles of therapy. Results: The median age of the patients was 46.5 years (range 26-72 years) and 54% were premenopausal. Performance status was ECOG 0 and 1 in 81 (99%) patients. The median number of cycles for capecitabine therapy was 5 (min-max: 2-18). The median ${\Delta}MCV$ level (post-treatment values at sixth week - baseline) was 6.4. Whilst ${\Delta}MCV$ was ${\geq}6.4$ in 42 patients, it was <6.4 in 40 patients. Clinical benefit (complete response+partial response+stable disease) was observed in 37 (88%) of 42 patients with a median ${\Delta}MCV$ ${\geq}6.4$ and in 30 (75%) of 40 patients with ${\Delta}MCV$ <6.4 with no statistically significant difference (p=0.158). No significant difference was determined between the group with ${\Delta}MCV$ ${\geq}6.4$ and the group with ${\Delta}MCV$ <6.4 in terms of progression-free survival (11 vs 12 months) (p=0.55) and overall survival (20 months vs. 24 months) (p=0.11). Conclusions: The identification of new predictive markers in metastatic breast cancer is very important. In some recent studies, increase in MCV has been suggested as a marker in tumor response. In the present study, however, no significant difference was determined between tumor response and increase in MCV. Further studies including higher numbers of patients are needed to determine whether increase in MCV is a predictive marker or not.

A Study on the Quality of a Frozen Section of Breast Resection Margin during Breast-Conserving Surgery (유방 보존술 중 절제면 동결절편검사의 질 향상에 관한 연구)

  • Choi, Byung-Il;Chin, Su-Sie
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.3
    • /
    • pp.233-240
    • /
    • 2021
  • Evaluation of the resected margins of the frozen section during breast-conserving surgery can determine the presence of cancer cells in a short time and have a significant impact on the scope of surgery and the prognosis of the patient. However, breast tissue is composed of adipose tissue, which affects the accuracy of the test. In this study, a new method was applied to the resected surface of the frozen section in which wiping the surface of the frozen section block with alcohol was expected to expose the parenchyma to the surface as the adipose tissue would melt momentarily. Indeed, of the total of 98 cases, 37 cases showed a better exposure ratio of the parenchyma in the improved frozen section test than in the previous frozen section test. Of the 37 cases with increased visibility of parenchymal sections obtained by this method, two cases of ductal carcinoma in situ (DCIS) were detected. Although there are limitations such as turnaround time (TAT), the diagnostic accuracy of histopathologic examination of the frozen section may improve through this method and may have a direct impact on patient safety, and should therefore be researched further.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

Cancer Detection Rates in a Population-Based, Opportunistic Screening Model, New Delhi, India

  • Shridhar, Krithiga;Dey, Subhojit;Bhan, Chandra Mohan;Bumb, Dipika;Govil, Jyostna;Dhillon, Preet K
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1953-1958
    • /
    • 2015
  • Background: In India, cancer accounts for 7.3% of DALY's, 14.3% of mortality with an age-standardized incident rate of 92.4/100,000 in men and 97.4/100,000 in women and yet there are no nationwide screening programs. Materials and Methods: We calculated age-standardized and age-truncated (30-69 years) detection rates for men and women who attended the Indian Cancer Society detection centre, New Delhi from 2011-12. All participants were registered with socio-demographic, medical, family and risk factors history questionnaires, administered clinical examinations to screen for breast, oral, gynecological and other cancers through a comprehensive physical examination and complete blood count. Patients with an abnormal clinical exam or blood result were referred to collaborating institutes for further investigations and follow-up. Results: A total of n=3503 were screened during 2011-12 (47.8% men, 51.6% women and 0.6% children <15 years) with a mean age of 47.8 yrs (${\pm}15.1yrs$); 80.5% were aged 30-69 years and 77.1% had at least a secondary education. Tobacco use was reported by 15.8%, alcohol consumption by 11.9% and family history of cancer by 9.9% of participants. Follow-up of suspicious cases yielded 45 incident cancers (51.1% in men, 48.9% in women), consisting of 55.5% head and neck (72.0% oral), 28.9% breast, 6.7% gynecological and 8.9% other cancer sites. The age-standardized detection rate for all cancer sites was 340.8/100,000 men and 329.8/100,000 women. Conclusions: Cancer screening centres are an effective means of attracting high-risk persons in low-resource settings. Opportunistic screening is one feasible pathway to address the rising cancer burden in urban India through early detection.

Breast and Cervical Cancer Screening in Women Referred to Urban Healthcare Centers in Kerman, Iran, 2015

  • Ahmadipour, Habibeh;Sheikhizade, Sahar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.143-147
    • /
    • 2016
  • Breast and cervical cancers are among leading causes of morbidity and mortality in women worldwide. Regular screening is very important for early detection of these cancers, but studies indicate low rates of screening participation. In this survey we studied the rate of screening participation among women 18-64 years old referred to urban health centers in Kerman, Iran in 2015. A cross-sectional study was carried out on 240 women who were selected using a multistage sampling method. Data collected using a questionnaire covered demographics and questions about common cancer screening status in women. Analysis was by SPSS 19. The mean age of participants was $31.7{\pm}7$. Most (97.1%) were married, housewives (83.3%), had high school diploma (43.8%) and a monthly income more than ten million Rls. The frequency of the Pap test performance was higher in women who were employed and with a university degree (p<0.05). The frequency of mammography performance in women over 40 years was also higher in women with university degree (p<0.05). There was no statistically significant difference in the frequency of pelvic examination, and self and clinical breast examinations based on education, household income and employment (p>0.05). Our study found that the rate of screening participation among women is low. Investigation of the barriers, increasing the awareness of women about the importance and advantages of screening and also more incentives for health personnel especially family physicians to pay more attention to preventive programs could be effective.

Disseminated Postnatal Cytomegalovirus Infection in a Preterm Neonate: Autopsy Case Report

  • Kim, Ka-Young;Kim, Ee-Kyung;Park, Sung-Hye;Kim, Yoo Jinie;Shin, Seung-Han;Kim, Han-Suk
    • Neonatal Medicine
    • /
    • v.28 no.2
    • /
    • pp.83-88
    • /
    • 2021
  • Treatment guidelines for postnatal cytomegalovirus (pCMV) infection in preterm have not been established yet. Neutropenia, thrombocytopenia, hepatitis, colitis, and sepsis-like disease are among the clinical manifestations, which range from moderate to serious. We present a case of autopsy diagnosed as pCMV infection in a premature infant delivered at gestational age of 24 weeks and 5 days. On the 7th and 14th days of birth, urinary CMV polymerase chain reaction samples were negative, ruling out congenital CMV infection. However, autopsy examination revealed that the patient had disseminated pCMV infection. CMV inclusion bodies were found in the majority of tissues, including the lung, liver, pancreas, breast, kidney, and adrenal gland, but not the placenta. The thymus exhibited significant cortical atrophy and T-cell immunodeficiency, possibly induced by dexamethasone treatment for bronchopulmonary dysplasia or by pCMV infection itself. If dexamethasone treatment is extended or high doses are considered, it may be beneficial to test the CMV infection status to prevent aggravation of infection. This case demonstrates that, despite the low prevalence, pCMV infection should be considered a differential diagnosis in preterm if other conditions or etiology cannot justify clinical deterioration.

Evaluation of Image Quality using Monte Carlo Simulation in Digital Mammography System (디지털유방영상시스템에서 몬테카를로 시뮬레이션을 이용한 영상평가)

  • Kim, Changsoo;Kang, Se-Sik;Kim, Jung-Hoon;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.247-254
    • /
    • 2014
  • For the purpose of early diagnosis of the breast cancer, the attention on the screening mammography has been increasing-with supply of digital mammography day by day. Image quality is decided by target materials and filter combinations. Optimized selection by a glandular density and a thickness is needed, because these combinations change x-ray spectrum and effect to image quality. The purpose of this study is to find out optimized target and filter combinations through the evaluation of quantitative image quality and to suggest means which minimize patient dose through MCNPX. In results, spatial frequency resolution evaluation which is quantitative image quality evaluation method, MTF, NPS, DQE shows that we have to select Mo/Mo combinations or Mo/Rh combinations when compressed breast is thin. but in case of that when compressed breast is thick, we have to select Rh/Rh combinations or W /Rh combinations. In a comprehensive evaluation, W!Rh combinations which are not used in thin breasts in practice was superior to all image quality evaluation. This result is somewhat different-with clinical examination results. Secondary end point was organ dose evaluation, radiation dose of opposite breast was approximately 47 ~73% effectiveness when selecting standard breast. In conculsion, the most important point is that we have to select the optimal combinations-with considering dose evaluation and various thickness.

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF