• Title/Summary/Keyword: clinic, hospital

Search Result 3,169, Processing Time 0.042 seconds

REPORT OF EXPERIENCE WITH KIMURA'S DISEASE (기무라씨 질환, 5 예 보고)

  • Seel David J.;Park Yoon-Kyu;Lee Kwang-Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1989
  • Kimura's Disease is a chronic inflammatory and proliferative condition producing subcutaneous masses especially in the head and neck area. This report of our experience with 5 patients with this disease is the first in the Korean surgical literature. Kimura's Disease is thought to be part of the larger spectrum of the entity known as angiolymphoid hyperplasia with eosinophilia (ALHE). It is characterized pathologically by hyperplastic lymphoid follicles, eosinophilic infiltration, and vase 비 ar proliferation. It produces masses which are most common in the area of the parotid, submandibular gland and upper neck. These masses occupy the subcutaneous tissues but also extend into salivary tissue and into upper neck nodes. One of our patients had masses in the groin. The tumors are extremely vascular due to the presence of new proliferative vessels and sinusoids. The average age of our 5 patients was 35, but all but one case were younger than 38 years of age. The male: female ratio was 3 : 2, and the average duration of symptoms was 5,2years. All patients had peripheral blood eosinophilia. All had multiple masses, sometimes symmetrical. The management was surgery alone in one case, surgery and steroids in one case, surgery and radiotherapy in two cases, and all three modalities in one case. The relationship of this entity to ALHE and our experience in the management of this disease are presented. A clinicopathological discrepancy alerted us to the existence of Kimura's Disease. A nineteen-year old male presented with subcutaneous masses over both mastoid areas present for 3 years (Case III). When biopsy on each side was reported as 'eosinophilic granuloma' we submitted the slides to an internationally expert pathologist. Symmetrically occurring tumors in the peri-parotid subcutaneous areas did not fit any category of neoplasm or granuloma known to us. The diagnosis, made by Dr. Gist Fan at the Ochsner Clinic, was Kimura's Disease. We found two additional cases in a review of soft tissue eosinophilic granuloma previously reported at Presbyterian Medical Center, and since then have diagnosed two new cases. These five cases constitute the basis for this, the largest series to be reported in Korea. These vascular, tumor-like lesions of the skin, subcutaneous areas and subjacent structures of the head and neck have been a variety of names, such as angiolymphoid hyperplasia with eosinophilia, eosinophilic hyperplastic lymphogranuloma, angioblastic lymphoid hyperplasia with eosinophilia, histioid hemangioma, and epithelioid hemangioma. The history of this disease spectrum dates back to 1937 when Kimm and Szeto (1) reported 7 cases of 'eosinophilic hyperplastic lymphogranuloma' in the Proceedings of the Chinese Medical Journal. In 1948 Kimura and his associates(2) reported additional cases in Japan under the title 'On the unusual granulation combined with hyperplastic changes of lymphatic tissue.' From then until 1966 several hundred cases were reported in China and Japan. The first report from the West was by Wells and Whimster(3) in the British Journal of Dermatology, in 1969. These authors coined the term, angiolymphoid hyperplasia with eosinophilia (ALHE). Since that time a debate has ensued as to whether Kimura's Disease and ALHE are distinct entities, or whether Kimura's is part of the larger spectrum of ALHE, perhaps a later or advanced phase. From the clinical perspective, surgeons should be aware of the diagnosis of Kimura's Disease not only as part of the differential diagnosis of head and neck tumors but also because these lesions are indolent, and generally require conservative surgical removal as part of the management program. CASE I. A 37-year-old female company employee presented in August 1982 with submental swelling of 12 years' duration and with inguinal swelling of 7 years' duration. The submental mass measured 5x5cm. and the inguinal mass was 8x4cm. in size. Peripheral eosinophilia varying from 14% to 40% was found. On August 20, 1982, the submental mass was removed and a superficial groin dissection was done. In May 1983 an intraoral lesion of the palate was removed. The patient is free of disease. CASE II. A 23-year-old unemployed man visited this hospital for the first time in July, 1984, with swelling of the right cheek present for 6 years. The mass was soft and ill-defined but measured 10x20cm. and extended from the submandibular upper neck to the zygomatic arch, and from the mastoid to the cheek, over the parotid gland. Eosinophilia varying from 27% to 29% was noted in the peripheral blood. On March 21, 1986, the lesion was resected. The procedure comprised an extended superficial parotidectomy from the temporalis fascia to the upper neck. Post-operatively radiotherapy 3000 rad tissue dose was administered using the 6 MeV linear accelerator. The patient remains free of disease. CASE III. A 19-year-old student came to the clinic with masses over both mastoid areas, present 3 years. On the right there were two adjacent lesions, one over the mastoid, the other in the upper jugular level of the neck. On the left it was a single mass over the mastoid. Eosinophilia varied from 13 to 32% in the peripheral blood, and 11.6% in the bone marrow. Incisional biopsy revealed 'eosinophilic granuloma' and a trial of predisolone was employed. The mass increased in size so a small dose of radiation (600 rads) was used, with substantial regression,. The lesion on the left was excised and follwed by 1000 rads radiotherapy. Finally recurrent tumor on the right side was removed on November 5, 1985. The patient remains free of disease. CASE N. A 29-year-old local merchant had had swelling of both upper necks since childhood. At the time of his first visit on March 17, 1986, the right submandibular mass measured 5x3.5cm. and the ,right upper neck and parotid tail mass measured 2.5cm. On the left there were masses in the upper neck, the largest of which measured 2.5cm, and of the parotid tail, 2.0cm. in size.(See Fig. 1) Peripheral eosinophilia of 39% was recorded. Left side partial parotidectomy and resection of the upper neck and subdigstric mases was done on May 2, 1986. The mass involving the right parotid tail and upper neck nodes was removed on Angust 7,1986. Postoperatively the patient was placed on prednisolone 30 mg. per day. No definite masses are palpable. CASE V. A 66-year-old housewife informed us, at the time of her first visit in May, 1986, that she had had multiple neck masses since 10 years ago. On the right side there was a 2.5cm. subcutaneous mass of the upper neck, over the upper jugular chain. On the left there was a 9x4.5cm. mass involving the entire parotid, the post-auricular area and the upper neck. A third mass presented in the submental area and measured 3.5cm. (See Fig. 2) Eosinophilia of 51% was noted in the peripheral blood. partial excision of the left upper neck lesion and complete excision of the submental mass were performed on june 6, 1986. post-operatively she was placed on 20 mg. of prednisolone daily, but when the mass re-grew after two months she was referred to Radiation Therapy for a 2500 rad course of treatment. A barely palpable thickening remains.

  • PDF

A STUDY ON THE PERSONALITY TRAIT OF BULLYING & VICTIMIZED SCHOOL CHILDRENS (학령기 집단따돌림 피해 및 가해아동의 인격성향에 관한 연구 - 한국아동인성검사를 이용하여 -)

  • Jhin, Hea-Kyung;Kim, Jong-Won;Choi, Yun-Jung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.94-102
    • /
    • 2001
  • Bullying has recently become a serious social problem in Korean society. Bullying, which is defined as a phenomenon that one particular student is intensively and continuously harassed or ostracized by a group of students, is apt to produce harmful effects on bullies as well as victims. Bullying has many causes including those originated from the personality of victims and bullies. This study is designed to investigate the difference in personality trait between victims, bullies, victims/bullies, and neither. The subjects of this study were 215(115 male and 100 female) 6th-grade students in the primary school in Seoul. Questionnares were distributed to the students and their carers. The student carers were also asked to answer the questions for a survey called the Korean Personality Invertory for Children(KPI-C). SPSS was used for the statistical analysis of the collected test information;ANOVA, post hoc scheffe test, and T-test were used to analyze the differences between the tested groups. The result of the study is as follows. 1) The victims, bullies, victims/bullies and neither totaled respectively 11(5.1%), 56(26.0%), 11(5.1%) and 137(63.7%). 115 were male and 100 were female. 2) The frequency of victimized is as follows:1 time is 15(7.0%), 2 times is 4(1.9%) and more than 3 times is 3(1.4%). The frequency of bullying is as follows;1 time is 40(18.6%), 2 times is 17 (7.9%) and more than 3 times is 10(4.7%). 3) The differences between froups in KPI-C test is as follows. (1) The ESR(p=.00) scale was significantly lower in the victims group than in the neither group and the HPR(p=.00) scale and PSY(p<.01) scale were significantly higher in the former than in the latter. (2) The ESR(p=.00) scale was significantly lower in the victims/bullies group than in the neither group and the SOM(p=.00) scale and HPR(p=.00) scale were significantly higher in the formaer than in the latter. (3) The SOC(p=.00) scale, PSY(p<.01) scale and AUT(p=.00) scale were significantly higher in the victims group than in the bullies group. (4) There is statistically no difference between the bullies group and the neither group. To conclusion, Victims need to learn how to cope with harsh situations, or they will have to face difficulties in relationships. Even after they experience bullying, they may not realize why they have been bullied, or speak out for themselves.

  • PDF

The study on the entry of dental technicians in the public health center for a manpower supply and demand plane (Centering around a denture insurance policy in 2012) (인력수급 대책을 위한 치과기공사의 보건지소 진출에 관한 연구 - 2012년 틀니보험화 정책을 중심으로 -)

  • Lee, Jong-Do;Kim, Jeong-Sook;Park, Kwang-Sig
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.417-433
    • /
    • 2010
  • Purpose: This study evaluated the manpower planning of dental technicians. Methods: Methods : Survey was conducted regarding subject's general characteristics, characteristics of dental technician's occupational view and working conditions, and reason to enter into branches of the public health enter. The survey sample consisted of 323 dental technicians (221 male/ 102 female). Survey was conducted for one month from August 1 to September 1 in 2010. Following results were obtained. Results: 1. Regarding general characteristics of the subjects, there was a slight male predilection with 68.4%. Subjects in their 40s occupied the highest proportion of 32.2%. Majority of subjects worked in the big cities (71.5%). Favored working places were dental laboratory (57.6%) and dental hospital or dental clinic (19.5%). Although no position is available in the public sector such as public health center or health care civil servant, 9.3% preferred working in the public health center. Public sector is more favored than 2-year technical colleges or dental supply and equipment companies. In respect to education, 57% of the subjects graduated college. 67.8% were married. Subjects who specialize in the porcelain or all-ceramic were 57.9%. With regard to current position, head of the dental laboratory was most common. 2. Following occupation characteristics were found. Economic reason took the highest proportion when deciding their occupation (39.9%) followed by gaining social experience (36.5%). Majority of the subjects (76.5%) wanted to work as dental technicians until their retirement. 71.5% pursuit to become a manager of the dental laboratory. 76.1% agreed on opening a dental technician position in the public health center. Regarding an authority to lead developing the dental technician position in the public sector, majority of the subject chose ministry of health and welfare (35.6%) and Korean dental technologist association (34.7%). Employment (average, 30%) and turnover rate (average, 36.5%) of dental technology college graduates ranged from 40% to 60%. Most important factors for the employment were practical experience (41.2%) and competency (34.4%). With regard to job satisfaction, so-so as 46.7% and satisfactory was 42.7% 3. In respect to the reason for opening a position in the public health center, 'It is needed to continue denture rogram for elderly patients' obtained the highest score (4.14 point). 'Institutional devices are required to open a position for dental technicians as a public healthcare provider' received high score (4.11 point). 4. Concerning the working conditions, 'professional knowledge is required' received the highest score (4.23) followed by 'too short maternity and parental leave' (4.21). 5. Relationship between general characteristics of the subjects and favor of working in the public health center was investigated. Significant differences were found according to the current and favored working area, favored occupation, education level, marital status, and specialty. Working in the public health center was favored by following subjects: working in mid- or small-sized cities (4.16 point, p<0.05); PhD degree-holder (4.59 point, p<0.01). 6. Among general characteristics of the subjects, significant difference of working conditions was found in the following factors: gender; working areas; favored working areas; favored working positions, and education level. Majority of subjects favored working in big cities and currently work in big cities although satisfaction was comparatively low (3.75 score). 7. Future plan to work in public health center was evaluated according to occupational characteristics. Subject's intention to work in the public healthcare center was significantly affected by opening of dental technician position, leading authority, average turnover rate, and factors affecting employment. Working in the public health care center was favored by the following subjects: Dental technicians who actively supported opening of the dental technician position (4.34 point, p<0.001); subjects who thought the Korean dental technologist association is responsible for the opening of positions in the public sector (4.26 point, p<0.001); and subjects who thought that attitude and character are important for the employment (p<0.001). 8. Concerning difference of working conditions according to the occupational characteristics, significant difference was demonstrated by factors such as a reason to choose to be a dental technician, work plan, pursuing position, responsible authority, average employment rate, and job satisfaction. High standard of working conditions was required in subjects who selected to be a dental technician for the leisure time after work (s.05 point, p<0.01), who planted to work until their marriage (4.25 point, p<0.001), and who pursuit to be a manager (3.98, p<0.05). 9. In respect to influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.068 and age affected the working condition with significant difference according to the pvalue. 10. Regarding influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.335 and work plan, opening of dental technician position in the public sector, and responsible authority had significant influence over the subject's intention to work in the public health center according to the p-value. 11. With regard to the influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.091 and reason to choose to be a dental technician, work plan, and responsible authority significantly affected subject's working conditions. Conclusion: Korean society is becoming a super-aged society according to several statistics. As aged population is rapidly increasing, national health insurance plans to cover denture for senior citizen over 75 years old from 2012. Therefore, dental technicians are urgently needed in the public health centers all over the nation. Many subjects in this study planed to work until their retirement and recognized dental technician's expertise. Ministry of health and welfare and Korean dental technologist association should co-operate each other to prepare foundation and institutional devices for dental technicians to advance into the public health center. This will improve oral health of the population. This study showed urgency of medical facilities and services which meets increasing number of aged population and welfare of the population.

Cephalometric Characteristics of TMD Patients based on RDC/TMD Axis I Diagnosis (RDC/TMD Axis I 진단에 따른 측두하악장애 환자의 측두 두부방사선적 특징에 관한 연구)

  • Ahn, Ji-Yeon;Kim, Yong-Woo;Kim, Young-Ku;Lee, Jeong-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.1
    • /
    • pp.39-51
    • /
    • 2011
  • The aims of this study were to investigate whether the facial skeletal patterns previously reported to be related to temporomandibular disorder (TMD) in other studies could be consistently observed in the TMD patients diagnosed according to Research Diagnostic Criteria for Temporomandibular Disorder (RDC/TMD) Axis I and evaluate its usability in the orthodontic clinics to examine the patients with TMD related symptoms. The clinical records and radiographs of female patients who visited the TMD and Orofacial Pain Clinic of Seoul National University Dental Hospital and were diagnosed as TMD were consecutively filed for this study. Patients were clinically examined and diagnosed according to the revised diagnostic algorithms of RDC/TMD Axis I and the lateral cephalogram, panoramic orthopantomogram, temporomandibular joint (TMJ) orthopantomogram, and transcranial radiograph of each patient were taken and digitalized. The data of patients who were under 18 years of age or had any systemic disease, trauma history involving the TMJ, or skeletal deformity at the time of the first examination were excluded. The remaining data of 96 female patients were finally analyzed. The obtained results were as follows: 1. There are no significant differences of cephalometric measurements between RDC I (muscle disorders) diagnostic groups. 2. Only the articular angle of the RDC group IIc (disk displacement without reduction without limited opening) patients was larger than patients of the no diagnosis of RDC II group (disk displacement). 3. Larger articular angle and smaller facial height ratio were observed in RDC IIIc group (osteoarthrosis) compared to IIIa group (arthralgia). Larger articular angle, larger Bjork sum, smaller posterior facial height, and smaller facial height ratio were observed in RDC group IIIc compared to no diagnosis of RDC III group (arthralgia, arthritis, and arthrosis). 4. According to the results of cephalometric analysis in simplified RDC groups, smaller overjet was observed in muscle disorders (MD) group. Facial height ratio and IMPA were smaller and articular angle was larger in disk displacements (DD) group than in no diagnosis of DD group. In arthrosis (AR) group, posterior facial height, and facial height ratio were smaller, and articular angle, gonial angle, facial convexity, FMA, Bjork sum, and ANB were larger than in no diagnosis of AR group. In joint pain (JP) group, only posterior facial height was smaller than no diagnosis of JP group. In conclusion, Facial morphologic patterns showing posterior-rotated mandible and lower posterior facial height is related to RDC group II and III diagnosis of the TMJ in female TMD patients. RDC/TMD Axis I diagnosis can provide a good clinical diagnostic tool for the standardized examination of the TMJ in orthodontic clinics.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

A Study on the Traumatic Teeth Damage of Children (어린이의 외상성 치아손상에 관한 연구)

  • Yoo, Su-Min;Park, Ho-won
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.21-25
    • /
    • 2004
  • In modern times, children's trauma is increasing every year because of car accidents and life environment changes. There is a limit to prevent traumatic damage for oral cavity organization. The fundamental data of trauma treatment and prevention will be presented through the survey and analysis of traumatic teeth damage. I examined 113 patients from Oct. 4th, 2000 to Feb. 27th, 2004 at Dept. of Children's Dental Clinic, Kangnung National University. The results are as follows. (1) The trauma frequency of male subjects is higher than that of female at a rate of 2.05:1. The average age is 5.27 for men and 5.27 for women. The highest percentage of trauma patients is among 2 year old children. It is 21.2%. (2) A patient survey was taken at a trauma treatment hospital. On the first day 34.4% of the patients had come to receive treatment of their first set of teeth. However, after a week, 38.8% of the patients had received treatment on their permanent teeth. (3) As a result of falling, 59% of patients needing treatment on their first set of teeth. 55.1% of patients is permanent teeth. As a result of bump against physical solid, 26.6% of patients is the first set of teeth and 26.5% of patients is permanent teeth. (4) Teeth damage happened at home. 42.1% were male. 35.1% were female. According to trauma, 59.4% of teeth damage happened at home. 28.6% of permanent teeth damage happened at school or kindergarten. (5) According to trauma, the number of teeth damaged was in the first set of teeth are as follows: 56.3%, one-31.3%, three or four-6.3% each. For permanent teeth: two-46.9%, one-28.6%, four over-16.3% and three-8.2%. Over four teeth is larger number for permanent teeth. (6) 56% of first set of teeth patients and 43.4% of permanent teeth patients were male. 56.8% of first set of teeth patients and 43.2% of permanent teeth were female. Trauma happened to both male and female frequently in the first set of teeth. (7) Most of the tooth damage which was in the first set of teeth and permanent teeth was done to the upper jaw. 75% of patients are the first set of teeth. 63.8% of patients are permanent teeth. Trauma is very high in the two mid teeth of the upper jaw. (8) According to trauma survey, 30.2% is from impulse. 28.0% is from crown fracture, 14.7% is from depression. 8.9% is from concussion. 7.1% is from full dislocation of a joint. 2.2% of patients are extrusion. 1.8% is from displacement. According to teeth damage trauma, 35.8% is pulse in the first set of teeth. The breaking of the crown of a tooth happened a lot in permanent teeth. (9) According to data, 43.2% of teeth damage in the first set of teeth goes without treatment. In permanent teeth, it is 38.9%. After treatment, 22.0% of first set of teeth treatment requires a dental pulp treatment. In permanent teeth, which is used for temporary acid etching resin restoration.

  • PDF

Clinical Outcome after Breast Conserving Surgery and Radiation Therapy for Early Breast Cancer (초기 유방암의 유방 보존수술 후 방사선 치료 결과)

  • Cho, Heung-Lae;Kim, Cheol-Jin;Park, Sung-Kwang;Oh, Min-Kyung;Lee, Jin-Yong;Ahn, Ki-Jung
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.204-212
    • /
    • 2008
  • Purpose: This study was performed to evaluate the disease-free survival and risk factors of recurrence in early breast cancer patients who have undergone breast conserving surgery and radiation therapy. Materials and Methods: From March 1997 to December 2002, 77 breast cancer patients who underwent breast conserving surgery and radiation therapy were reviewed retrospectively. The median follow-up time was 58.4 months (range $43.8{\sim}129.4$ months) and the mean subject age was 41 years. The frequency distribution of the different T stages, based on the tumor characteristics was 38 (49.3%) for T1, 28 (36.3%) for T2, 3 for T3, 7 for T is and 1 for an unidentified sized tumor. In addition, 52 patients (67.5%) did not have axillary lymph metastasis, whereas 14 patients (18.1%) had $1{\sim}3$ lymph node metastases and 3 (0.03%) had more than 4 lymph node metastases. The resection margin was negative in 59 patients, close (${\leq}2\;mm$) in 15, and positive in 4. All patients received radiation therapy at the intact breast using tangential fields with a subsequent electron beam boost to the tumor bed at a total dose ranging from 59.4 Gy to 66.4 Gy. Patients with more than four positive axillary lymph nodes received radiation therapy ($41.4{\sim}60.4\;Gy$) at the axillary and supraclavicular area. Chemotherapy was administered in 59 patients and tamoxifen or fareston was administered in 29 patients. Results: The 5 year overall survival and disease-free survival rates were 98.08% and 93.49%, respectively. Of the 77 patients, a total of 4 relapses (5.2%), including 1 isolated supraclavicular relapse, 1 supraclavicular relapse with synchronous multiple distant relapses, and 2 distant relapses were observed. No cases of local breast relapses were observed. Lymph node metastasis or number of metastatic lymph nodes was not found to be statistically related with a relapse (p=0.3289) nor disease-free survival (p=0.1430). Patients with positive margins had a significantly shorter disease-free survival period (p<0.0001) and higher relapse rates (p=0.0507). However, patients with close margins were at equal risk of relapse and disease-free survival as with negative margins (p=1.000). Patients younger than 40 years of age had higher relapse rates (9.3% vs. 0%) and lower disease-free survival periods, but the difference was not statistically significant (p=0.1255). The relapse rates for patients with tumors was 14% for tumor stage T2, compared to 0% for tumor stage T1 tumors (p=0.0284). A univariate analysis found that disease-free survival and relapse rates, T stage, positive resection margin and mutation of p53 were significant factors for clinical outcome. Conclusion: The results of this study have shown that breast conservation surgery and radiation therapy in early breast cancer patients has proven to be a safe treatment modality with a low relapse rate and high disease-free survival rate. The patients with a positive margin, T2 stage, and mutation of p53 are associated with statistically higher relapse rates and lower disease-free survival.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF