• 제목/요약/키워드: cleaning etc

검색결과 150건 처리시간 0.035초

자수 및 직물 공예품의 보존처리 (Conservation of Embroidered Textiles and Textile Works)

  • 유효선
    • 복식
    • /
    • 제58권5호
    • /
    • pp.198-210
    • /
    • 2008
  • The purpose of this study is to establish the conservation methods of embroidered textiles and textile works. The conservation of remained textiles is consisting of examination, cleaning, support and consolidation, restoration, and storage and display process. It aims to prevent the damage on textile remains for long time display and storage and to prolong their aesthetics and functionality. The embroidered textiles and textiles works, which are remained by handed down or excavated or included in the Buddhist are embossed with colorful threads on the fabrics: the stitches include embroideries on clothing, bed clothes, wrapping clothes, utensil pouches, panels and Buddhist goods; textile works include hats, ornaments, shoes, attachments of clothes etc. These are composed of mainly fabrics, precious metals, leathers and precious stones, etc., and are fabricated by several techniques such as braiding, twining, sewing as well as weaving. Metal threads were also used to add a decorative effect on these goods. In order to conserve and preserve the remained goods, a special care must be taken on the metal threads, which are the most fragile material among the constituents. Hence, characteristics of metal threads and its cleaning methods, general conservation techniques of a rank badge, which is brocaded and partly attached to Cheogori and Samo(men's hat) from the excavated old tombs are introduced here.

감은사지서삼층석탑의 표면오염물 분석과 제거기술 (Analysis of Surface Contaminants and Removal Techniques on Three-story Stone Pagoda at the West of Gameunsaji Site)

  • 김사덕;이태종;김다람;한민수
    • 보존과학회지
    • /
    • 제26권2호
    • /
    • pp.203-211
    • /
    • 2010
  • 감은사지서삼층석탑의 표면오염물과 세척사례 조사 연구는 부재 표면에서 관찰되는 무기오염물의 성분분석과 오염물 제거 방법을 선정하기 위해 실시하였다. 표면오염물 조사는 육안관찰과 주사전자현미경, XRD를 이용하여 오염물의 상태를 파악하고 정성 정량분석을 통해 비교 분류하였다. 분석결과, 표면오염물은 철화합물이나 황화합물 등 화합물로 존재하며, 결정 형태는 원형, 타원형, 침상, 각형이 주를 이룬다. 오염물을 제거할 수 있는 방법을 검토한 결과, 미립재를 와류형식으로 분사하는 저압와류세척방법이 적당한 것으로 사료된다.

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

유기용제에 의한 탈지세정 (도장전처리로써의) (Cleaning with Organic Solvent)

  • 죽내절삼
    • 한국기술사회:학술대회논문집
    • /
    • 한국기술사회 1984년도 한일 합동 심포지움
    • /
    • pp.52-60
    • /
    • 1984
  • As far as we handle industrial products, the painting process is prerequisite; and the preparatory treatment of materials is, therefore, indispensable to the above process. However, it is a matter for regret that people are liable to overlook the importance the treatment of materials at the preparatory stage, giving themselves up to the surface of finished goods. The preparatory treatment of materials is like backstage personnel (operations) in dramatic performance; the performance cannot be successful without the support of backstage operations in surface treatment. The various methods which are being applied widely as preparatory treatment are as follow: (1) the method by using hand tools such as grinders, etc. (2) the method with blasting (3) the method with chemical coating (4) the method by getting rid of fatty substance with organic solvent The methods No. 1 and No. 2 are in use mainly for larger structures, and those No. 3 and No. 4, either singly or combined, are applied for mass-produced, smaller items (acid cleaning is applied for getting rid of rust, as the case may be). The method No. 3 is used mainly as anti-rust by forming zinc phosphate film on the surface of steel plate or enhancing the bonding power of paints by taking advantage of irregular surfaces of films. Recently are no the market steel plates treated directly with film-coating by omitting the process No. 3. Furthermore, those goods painted include not only nonferrous goods but plastics and elastomer. The present discourse describes the cleaning process by using the steam of organic acid, picked up from among No. 4, and its equipment applied.

  • PDF

논문 - 바이오가스화 도입을 위한 양돈농가 가축분뇨 발생 및 특성분석 (Generation and Characteristics Analysis of Swine Manure for Introducing Biogas System)

  • 최은희;윤영만;김창현
    • 한국관개배수논문집
    • /
    • 제18권2호
    • /
    • pp.25-32
    • /
    • 2011
  • The 21 livestock farms considering future installation of biogas systems were studied. These farms were examined how to raise the livestock, to treat manure, to operate facility with respect to manure characteristics. The 15 farms out of 21 farms have applied to the marine dumping and consignment treatment for treating manure and even farms which have equipped liquid fertilizing system have less capacity facility than legal standards. Characteristics of manure were affected by the scale of swine barn, clean water usage, frequency of cleaning, cleaning method, feces-urine separating method, etc. Retention time in storage (over 20 days) has resulted in lower concentration of organic matter which could reduce biogas production. This indicates that systematic barn management system is required. Inhibition tests showed that disinfectant and citric acid did not affected digestion rates at 10 times higher concentration than recommendation. However hypochlorous acid is likely to affect the anaerobic microbial activity.

  • PDF

자력선별법에 의한 선탄의 탈황 (COAL DESULFURIZATION BY MAGNETIC SEPARATION METHODS)

  • 전호석;이재장
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.175-185
    • /
    • 1995
  • Under the new environmental regulations announced by the government, utilities will have to cut their sulfur dioxide emissions by 60% from 1991 levels by the year of 1999. Sulfur dioxide emissions can be reduced prior to combustion by physical, chemical or biological coal cleaning. The new technology of high gradient magnetic separation (HGMS) offers the potential of economic separatoins of a variety of fine, weakly magnetic minerals including inorganic sulfur and many ash-forming minerals from coals. In the present paper, magnetic separation tests have been conducted on Korean anthracite and high-sulfur Chinese coal to investigate the feasibility of these techniques for reducing sulfur content from coals. In wet magnetic separation, the studied operating parameters include particle size, pH, matrix types, feed solids content, feed rate, number of cleaning stages and etc. The results shows that for wet separation, 60~70% of total sulfur was removed from coals with over 80% combustible recovery, on the other hand, for dry separation, 47.6% of total sulfur was removed from coals with 75% recovery.

  • PDF

디클로로메탄 사용 세척공정의 국소배기장치 설치 후 노출농도 변화 (Change in Exposure Concentration in the Cleaning Process after Installing a Local Exhaust System)

  • 조명화;김승기;김현수
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.280-283
    • /
    • 2023
  • Objectives: The purpose of this study was to examine the change in exposure concentration in the cleaning process after installing a local exhaust system. Methods: Dichloromethane measurement was conducted according to the KOSHA Guide (A-19-2019). Results: After the local exhaust device was installed, a total of three measurements were conducted, including temporary work environment measurements, and all of the measurements did not exceed the DCM exposure standard, but were more than 50% of the DCM Time Weighted Average((8-TWA) Conclusions: It is thought that the local ventilation system of a small business needs not only support for the initial installation cost, but also educational support for maintaining the performance of the local ventilation system and support for consumables (adsorbents, filters, etc.) that incur periodic costs.

유해가스 처리를 위한 Confined Plasma Source 개발 (Development of Confined Plasma Source for Hazardous Gas Treatment)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.135-140
    • /
    • 2020
  • 반도체 공정에서 필수적인 공정가스가 유해가스이기 때문에 이를 친환경적으로 해결하는 것이 필수과제이다. 현재 반도체 공정에서 사용되는 세정기술은 대부분이 1970년대 개발된 과산화수소를 근간으로 하는 습식 세정으로, 표면의 입자를 제거하기 위한 SC-1 세정액은 암모니아와 과산화수소 혼합액을 사용하고 있다. 따라서 환경적 문제를 유발하며, 또한 과도한 용수 사용으로 인한 경제적 문제도 심각하다. 이러한 이유로 본 연구를 통한 개발 제품은 챔버 출구에서 나오는 공정 유해가스를 진공펌프에 입력되기 전 가스를 분해하여 해가 없는 가스로 만들거나 소각과 동시에 펌프에 가스의 성분이 증착되어 반도체 공정의 환경적 문제를 해결하고자 한다. 본 논문에서는 반도제 공정에서 필수 불가결하게 사용되는 유해가스(N2, CF4, SF6⋯. 등)를 사람에게 무해한 가스로 치환하거나 플라스마로 소각하여 환경을 살리고 생산성 향상이 되도록 제안된 CPS (Confined Plasma Source)를 연구하고자 한다.

복류수를 이용한 한외여과공정의 장기운전 평가 (Long Term Evaluation of UF Membrane process using River-bed Water)

  • 김충환;임재림;강석형;김수한
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

중.고등학교 남.여 청소년의 에너지 소비실태 (The Estimation of the Daily Energy Expenditure of Korean Adolescents)

  • 김영남;나현주
    • 대한지역사회영양학회지
    • /
    • 제8권3호
    • /
    • pp.270-279
    • /
    • 2003
  • Middle and high school students in Korea spend a lot of time at school. In other words, many Korean teenagers spend most of their time studying, and have little time for other activities, such as physical workouts. Fewer physical activities, and consumption of many snacks, etc. may lead to overweight or obesity in some teenagers. This study was conducted to find out the activity levels of teenagers' in order to calculate their daily energy expenditures. A total of 1,192 students (461 middle school students and 731 high school students) who lives in either a city or a country area were recruited for this study. One-day Activity Diaries were collected using questionnaires and analyzed by means of SPSS /win. The participating students spent about 7 hours 24 minutes resting including sleeping; 6 hours 28 minutes studying ,4 hours 4 minutes in leisure activities , 1 hour 32 minutes in personal hygiene activities such as washing, dressing and undressing, etc., 50 minutes on transportation : and 23 minutes on household chores such as cleaning, doing the laundry, etc. The average activity factor was 1.49. That of middle school female students was the lowest at 1.47, followed by middle school male students at 1.48, high school female students at 1.49, and high school male students at 1.51. The daily energy expenditure of middle and high school male students was 2,289 kcal and 2,600 kcal, respectively. That of female students was 1,959 kcal and 2,067 kcal, respectively.