• Title/Summary/Keyword: cleaner

Search Result 673, Processing Time 0.027 seconds

Effect of Interfacial Properties on the Detergency in Dishwashing Agent Composition (식기용 세정제 조성에 있어서 계면물성이 세정력에 미치는 영향)

  • Oh, Hyun-Joo;Lim, Hyo-Seon;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.193-199
    • /
    • 2020
  • The effects of the composition of the dishwashing detergent on interfaces of the oil (O) and the aqueous (W) solution in addition to the cleaning effects of interfacial properties were investigated. Also, the cleaning power of the oil contaminated on the surface of the dish according to each composition and the residuals of the contaminants and the cleaning agent after the washing rinses were evaluated. The removal of contaminated oil on the solid (S) surface in the composition of the cleaning agents used in this study was strongly related to the interfacial properties between the W/O/S, and was particularly dependent on the forward and backward dynamic contact angles. When both contact angles were low at the same time, the permeability of the cleaning solution was so high that the contaminated oil showed a high removal effect. The smaller the interfacial tension of O/W was, the better emulsification of the contaminated oil, the higher the interfacial tension, and the poorer emulsification were achieved. However, the emulsification effect did not significantly affect the cleaning power. In particular, in the case of the cleaner having low interfacial tension, the cleaning material remained on the surface of the solid after washing.

A Study to Recover Si from End-of-Life Solar Cells using Ultrasonic Cleaning Method (초음파 세척법을 이용한 사용 후 태양광 셀로부터 Si 회수 연구)

  • Lee, Dong-Hun;Go, Min-Seok;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.30 no.5
    • /
    • pp.38-48
    • /
    • 2021
  • In this study, we determine the optimal process conditions for selectively recovering Si from a solar cell surface by removal of impurities (Al, Zn, Ag, etc.). To selectively recover Si from solar cells, leaching is performed using HCl solution and an ultrasonic cleaner. After leaching, the solar cells are washed using distilled water and dried in an oven. Decompression filtration is performed on the HCl solution, and ICP-OES (Inductively Coupled Plasma Optical Emission spectroscopy) full scan analysis is performed on the filtered solution. Furthermore, XRD (X-ray powder diffraction), XRF (X-ray fluorescence), and ICP-OES are performed on the dried solar cells after crushing, and the purity and recovery rate of Si are obtained. In this experiment, the concentration of acid solution, reaction temperature, reaction time, and ultrasonic intensity are considered as variables. The results show that the optimal process conditions for the selective recovery of Si from the solar cells are as follows: the concentration of acid solution = 3 M HCl, reaction temperature = 60℃, reaction time = 120 min, and ultrasonic intensity = 150 W. Further, the Si purity and recovery rate are 99.85 and 99.24%, respectively.

A Comparative Study on the Food Hygiene Attitude and Personal Hygiene Management of High School Students according to Gender (고등학생의 식품위생태도와 개인위생관리의 성별에 따른 비교연구)

  • Kim, Suk Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.207-213
    • /
    • 2019
  • This study aimed to provide basic data for the development of education programs on food hygiene attitude and personal hygiene management of high school students according to gender. From July 16 to October 15, 2015, questionnaires were distributed to 30 students per grade at 16 high schools in Chungcheongnam-do, and a total of 1,214 questionnaires(excluding uncollected and insufficient questionnaires) were processed using SPSS(ver 18.0). According to the study, female students more checked the expiration date for food(3.78, 3.57), ate stored food without heating(2.83, 3.02) and stored it according to the characteristics(3.92, 3.72) than male students. On the other hand, male students answered they looked at food packaging more closely(3.34, 3.22), and always used personal plates when they ate(3.43, 3.32), than female students. Female students were always better at hand washing after went to toilet(4.25, 3.94), used individual cups when using water purifiers(3.45, 3.32), kept nails cleaner(3.61, 3.49), and went around(2.14, 2.53) and went to toilet during meals than male students(2.22, 2.57). Boys answered they were better at hand washing before meals(3.64, 3.50), with right way(3.58, 3.46), and covering with a tissue, handkerchief or sleeve when they coughed(3.55, 3.37) than girls. In this study, high school students showed significant differences between gender in food hygiene attitude and personal hygiene management, with different areas requiring improvement. Therefore, this study suggests the need for education on food hygiene attitude and personal hygiene management differentiated according to gender.

A Study for Fire Examples Involved in Engine Coolant leakage, Brake and Exhaust System Over-Heating of Heavy-Duty Truck Vehicle (대형 트럭 자동차의 엔진냉각수 누출, 제동 및 배기시스템 과열에 관련된 화재사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Young Suk;Hwang, Han Sub;You, Chang Bae;Moon, Hak Hoon;Jung, Dong Hwa;Ahn, Ho Cheol;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.40-45
    • /
    • 2019
  • This paper is a purpose to study the failure example for heavy-duty vehicle fire. The first example, the researcher found the engine over-heating phenomenon causing a coolant leakage by the sealing poor of head-gasket because of D-ring part deformation contacting with cylinder liner top-part and cylinder head. He certified a fire breakout by short transferred to surrounding wiring of air-cleaner. The second example, a brake lining by return fault of break operating S cam causing with much wear of a rear 4 wheel brake lining repeatably was worn by friction. In the long run, it became the cause of fire. The third example, the researcher knew the fire cause was came about the short of wire by overload of tilting motor when the driver tilted up the cap to inspect a engine. Therefore, a heavy-duty fire must minimize the fire occurrence by thorough controlling.

Study on Degradation Characteristics and Chemical Cleaning Methods of Plasticized PVC for Conservation of Plastic Artifact (연질 PVC 작품 보존을 위한 가소제 종류별 열화 특성 및 화학적 세척법 연구)

  • Lee, Na Ra;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.159-168
    • /
    • 2019
  • Plasticizers, which are added to plastics, can cause exudation, which means that the plasticizer comes out from surface of the plastics. This causes the surface of plastic artworks to become sticky, and this allows dust and pollutants to become attached to the surface. Therefore, in this study, the degradation characteristics and chemical cleaning methods of each type of plasticizer are evaluated using PVC specimens. To evaluate the degradation characteristics and chemical cleaning methods, microscopic observation, chromaticity and weight measurement, and FT-IR spectroscopy were performed. The results showed that PVCs containing different plasticizers have different degradation patterns. Especially, the PVC containing TOTM showed discoloration and exudation. In the evaluation of the chemical cleaning methods, ethyl alcohol and KOH solution showed good effects, but their stability was not good. Surfactant was found to have a good cleaning effect and stability as a cleaner for exudated plasticizers.

Evaluation of Indoor Mold Exposure Level in dwelling Using DNA-Based Mold Assessment Method (DNA 기반 곰팡이 평가기법을 활용한 주택의 실내 곰팡이 노출수준 평가)

  • Hwang, Eun-Seol;Seo, Sung Chul;Lee, Ju-Yeong;Ryu, Jung-min;Kwon, Myung-Hee;Chung, Hyen-Mi;Cho, Yong-Min;Lee, Jung-Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.4
    • /
    • pp.382-392
    • /
    • 2018
  • Objective: Allergic diseases such as asthma due to fungal exposure in houses have increased, and proper management is urgent. Mold can grow in the air, floor, walls, and other areas according to environmental conditions, and there are many limitations to the conventional methodology for examining fungal exposure. For this reason, the degree of fungal contamination is being evaluated by ERMI (Environmental Relative Moldiness Index), a quantitative analysis method proposed by the EPA. In this study, we compared ERMI values between water-damaged dwellings and non-damaged ones to evaluate the effectiveness of Korean ERMI values. We also explored the association of ERMI values with the level of airborne mold and characteristics of dwellings. Methods: Floor dust was collected after installing a Dustream collector on the suction port of a vacuum cleaner. The collected samples were filtered to remove only 5 mg of dust, and DNA was extracted using the FastDNA SPIN KIT protocol. Results: The ERMI values were found to be 19.6 (-6.9-58.8) for flooded houses, 7.5 (-29.2-48.3) for leaks/condensation, and 0.8 (-29.2-37.9) for non-damaged dwellings. The airborne concentration of mold for flooded, leakage or condensed, and non-damaged houses were $684CFU/m^3$, $566CFU/m^3$, and $378CFU/m^3$, respectively. The correlation between ERMI values and the levels of airborne mold was low (R = 0.038), but a weakly significant association of the ERMI values with the concentration of particulate matter ($PM_{10}$) was observed as well(R=0.231,P<0.05). Conclusions: Our findings show that the reference value using ERMI can be used to distinguish water-damaged and non-damaged dwellings. It is believed that ERMI values could be a promising tool for assessing long-term fungal exposure in dwellings.

On an Application of the Sound Massage for Safe Wet Shaving (안전한 습식면도를 위한 소리마사지 적용 연구)

  • Tian, Zhixing;Bae, Myung-Jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.605-609
    • /
    • 2022
  • Shaving for adult men is one of the essential requirements for life. For physiological reasons, most adult men have beards, and if men trim their beards and take good care of them, their appearance becomes cleaner. If a dull blade is used for a wet razor, or if an appropriate massage is not used, skin irritation may occur, resulting in shaving wounds. Therefore, the convenience and comfort of the razor are required as much as the skin becomes smooth after shaving. In this paper, a pre-shaving method of sound massage was proposed to reduce the irritation of wet shaving on the skin and increase the convenience of shaving. It softens the skin or secretes oil through non-face-to-face low-frequency speakers to increase skin gloss, making shaving smooth and safe. We recorded the sound of the wet shave state to determine the skin condition before and after the wet shave, and objectively compared and analyzed the effect with this sound spectrum. In other words, it can be seen from the experimental results that the sound massage before shaving reduces the friction between the razor and the skin and the skin and beard by -7.0 dB, improving the skin wound of the wet shave and achieving a refreshing shave.

Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2 (지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교)

  • Lee, Gunhee;Kim, Sang Bok;Park, Inyong;Hong, Kee Jung;Lee, Yeawan;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

A Study on the Applicability of $C_5$ Hydrofluoroether-based Formulated Cleaning Agents as CFC-Alternatives ($C_5$계 수소불화에테르를 기반으로 하는 배합 세정제의 CFC 대체세정제 적용 연구)

  • Min, Hye-Jin;Bae, Jae-Heum;Chang, Yoon-Sang
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.172-181
    • /
    • 2010
  • Hydrofluoroethers (HFEs) with fluoride molecules in their structure which are evaluated as the third generation replacement alternatives to chlorofluorocarbons (CFCs) are known to be excellent for removal of nanoparticles and fluoride-type soils due to their low surface tension and high wetting index. In addition, HFEs have good physical properties with no flash point and excellent drying characteristics. But, HFEs also have shortcomings in that they are not effective for removal of organic soils due to their poor solubility in soil. In this study, $C_5$ HFE-based cleaning agents were formulated through addition of solvents such as isopropyl alcohol (IPA), ethyleneglycol monoether (EG), propyleneglycol monoethylether (PM) to HFE-7100 [$CF_3CF_2CF_2CF_2OCH_3$] or HFE-mec-f [$CF_3CHF=CF_2OCH_2CF_3$] with its maximum amount, respectively, in order to have no flash point for the safety in the working environment. These solvents are known to be excellent for dissolving organics in soil. Their physical properties and cleaning abilities for fluxes, water-insoluble cutting oils, and fluoride-type oils were evaluated and compared with those of other cleaning agents with single components. The experimental results show that the HFE-based formulated cleaning agents have various good physical properties which are almost similar to those of a single type of HFE cleaner. They show excellent cleaning ability for fluxes, water-insoluble cutting oils, and fluoride-type oils. These results indicate that the HFE-based formulated cleaning agents can be applicable to various industrial cleaning fields because of their good physical properties and cleaning abilities for various soils.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.