• Title/Summary/Keyword: clean시스템

Search Result 608, Processing Time 0.028 seconds

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (II) - Assessment of the FDA System through a Site Application - (시설용수 및 영농편의용수 공급시스템 개발 (II) - FDA 시스템 현장적용성 평가 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.101-106
    • /
    • 2009
  • The previous study developed the Filter-Disinfection-Adsorption (FDA) system to provide clean irrigation water for greenhouse cultivation as well as convenience water to farmers. In this study, the field examination was undertaken to assess performance of the FDA system. The field application was made in the suburb of Daegu, one of the large city in Korea. The study area located near by down-stream of Gum-Ho river is suffering low irrigation water quality problems with no water supply service facilities. Four water quality parameters including Suspended Solid (SS), Biological Oxygen Demand (BOD), coliform, and turbidity were selected to test the purification performance of FDA system. Also in order to improve the system, this study investigated the defects of using the FDA system through field monitoring. As results, it was found that this system can be used to supply good quality of irrigation water for greenhouse cultivation and also provide convenience water to farmers in the field areas of no water supply services.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System - (시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.

Mechanical Properties of Heat Exchanger Element with Higher Capacity Waste Heat Recovery PDC Clean Ventilation System (대용량 폐열회수 PDC청정 환기시스템용 열교환 소자의 기계적 특성)

  • Ahn, S.H.;Nam, K.W.;Ahn, B.H.;Kim, D.G.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.67-75
    • /
    • 2009
  • Recently, the higher capacity waste heat recovery PDC clean ventilation system has a tendency which is increasing due to the excellent energy reduction in factory, big building, and so on. This system was developed to complement the room environment which is deteriorated. However, the researches and technologies about this system were not well studied. Specially, the characteristic for heat exchanger element used to this system were not well known. Therefore, this study was carried out to evaluate the mechanical properties of the heat exchanger element as the core parts compose of this system. From results, tensile strength and elongation of the plate type heat exchanger element had about 10.11~14.32 kgf/$mm^2$ and 8.0~16.2%, respectively.

  • PDF

A Basic Study On the Estimative Direction of Responsible Ability for HNS National Contingency Plan Using Powersim (파워심을 이용한 HNS 국가방제기본계획의 방제능력 산정방향에 관한 기초 연구)

  • Lee Sang-Bae;No Chang-Gyun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.209-214
    • /
    • 2006
  • This paper desires to assist ensuring of propriety clean-up equipment for clean-up shore or sea of pollution, there is not that responsible ability of a nation has an amount of skimmer or the length of boom. responsible ability of a nation must express overall evaluation what is considering quickly, system, and economizing in addition to an amount or clean-up equipment. responsible ability of a nation is complication and it's mutual relation of each other factor therefore responsible capacity of a nation is expressed using powersim with system dynamics theory.

  • PDF

Air Gasification Characteristics of Unused Woody Biomass in a Lab-scale Bubbling Fluidized Bed Gasifier (미이용 산림바이오매스 및 폐목재의 기포 유동층 Air 가스화 특성 연구)

  • Han, Si Woo;Seo, Myung Won;Park, Sung Jin;Son, Seong Hye;Yoon, Sang Jun;Ra, Ho Won;Mun, Tae-Young;Moon, Ji Hong;Yoon, Sung Min;Kim, Jae Ho;Lee, Uen Do;Jeong, Su Hwa;Yang, Chang Won;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.874-882
    • /
    • 2019
  • In this study, the gasification characteristics of four types of unused woody biomass and one waste wood in a lab-scale bubbling fluidized bed gasifier (Diameter: 0.11 m, Height: 0.42 m) were investigated. Effect of equivalence ratio (ER) of 0.15-0.3 and gas velocity of $2.5-5U_0/U_{mf}$ are determined at the constant temperature of $800^{\circ}C$ and fuel feeding rate of 1 kg/h. The silica sand particle having an average particle size of $287{\mu}m$ and olivine with an average particle size of $500{\mu}m$ were used as the bed material, respectively. The average product gas composition of samples is as follows; $H_2$ 3-4 vol.%, CO 15-16 vol.%, $CH_4$ 4 vol.% and $CO_2$ 18-19 vol.% with a lower heating value (LHV) of $1193-1301kcal/Nm^3$ and higher heating value (HHV) of $1262-1377kcal/Nm^3$. In addition, it was found that olivine reduced most of C2 components and increased $H_2$ content compared to silica sand, resulting in cracking reaction of tar. The non-condensable tar decreases by 72% ($1.24{\rightarrow}0.35g/Nm^3$) and the condensable tar decreases by 27% ($4.4{\rightarrow}3.2g/Nm^3$).

Design Standard of Activated Carbon Vessel for the Intermittent Emission Sources of Volatile Organic Compounds (휘발성 유기화합물의 간헐적 배출원에 대한 활성탄 흡착 시스템 설계기준)

  • Lee, Si-Hyun;Lim, Jeong-Whan;Rhim, Young-Jun;Kim, Sang-Do;Woo, Kwang-Je;Son, Mi-Sook;Park, Hee-Jae;Seo, Man-Cheol;Ryu, Seung-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.250-260
    • /
    • 2007
  • It was investigated that the emission characteristics of volatile organic compounds (VOCs) from small and medium companies located on industrial complexes in Metropolitan area. The emission characteristics are intermittent sources in which VOCs emissions are highly depends on the working condition. Optimized ventilation system to improve air quality in working area for the three typical companies were installed. Adsorption characteristics of major VOCs such as MEK, IPA, and toluene emitted front the companies were investigated for design of the activated carbon vessel as a VOCs control facility in each company. Concentration of total hydrocarbon and gas amounts needed to ventilation were also used as a design parameter. Mixed adsorbent to improve adsorption characteristics of problematic solvents like IPA and the design guideline of the activated carbon vessel have been suggested.

A Trend of Sustainable Recycling Systems of Spent Nuclear Fuels (지속가능한 사용후-핵연료 재활용 시스템의 개발 동향)

  • Kim, Seong-Ho
    • Journal of Energy Engineering
    • /
    • v.20 no.3
    • /
    • pp.236-241
    • /
    • 2011
  • In this study, considering a degree of proliferation resistance and sustainability, development status of perspective recycling systems for spent nuclear fuels (SNF) is comprehensively reviewed on the basis of the urgent needs of sustainable management measures for high level radioactive wastes such as spent nuclear fuels (SNF).

A Study on the Performance Improvement of the Air Washer System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 에어와셔 시스템의 성능개선을 위한 연구)

  • Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3413-3417
    • /
    • 2007
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. In the present study, an experiment was carried out to examine the improvement of removal efficiency for the gaseous contaminants. In order to improve the gas removal efficiency, a hot water contact heat exchanger was installed upstream of the air washer to heat and humidify the incoming outdoor air before entering the air washer.

  • PDF

An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가)

  • Yeo, Kuk-Hyun;Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

Analysis of Greenhouse Gas Emission associated with Clean Energy Agriculture System Development (청정에너지농업시스템 개발에 따른 실증단지의 온실가스배출량 분석)

  • Kim, Tae-Hoon;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.4
    • /
    • pp.643-658
    • /
    • 2015
  • This study presents detailed emission of greenhouse gases of using Clean Energy Agriculture System according to a cradle-to-gate life-cycle assessment, including emission from energy use and leak of Biogas. Calculations were done with the PASS software and the covered gases are $CH_4$, $N_2O$ and $CO_2$, Total GHG fluxes of amount to $1719.03kgCO_2/day$, $39.63kgCO_2/day$ (2.31%) are from facility house process, $0.19kgCO_2/day$ (0.01%) are from transport process, $696.72kgCO_2/day$ (40.53%) are from Anaerobic digestion process, $846.61kgCO_2/day$ (49.25%) are from Heating and cooling system, $135.88kgCO_2/day$ (7.90%) are from Fertigation production process. The results suggest that for effective reduction of GHG emissions from Facility house using clean energy. Reduction targets should address both the production process as defined by IPCC sectors and the consumption process. An LCA assessment as presented here could be a basis for such efforts.