• 제목/요약/키워드: circumferential layer

검색결과 44건 처리시간 0.026초

뒷날에 붙인 회전자로 순환유동을 강화하는 날개장치의 성능 연구 (A Study on the High Lifting Device Equipped with the Trailing Edge Rotor for the Enhancement of Circulation Control)

  • 오정근;김효철
    • 대한조선학회논문집
    • /
    • 제47권4호
    • /
    • pp.533-542
    • /
    • 2010
  • For a long times it has been believed that the Magnus effect of the rotating cylinder could be utilized for the lifting devices applicable to marine practices. It has been reported that the rotating cylinder installed on upper deck of commercial vessel could play a energy saving role however the idea might be applicable in a very rare case in ship building practices. In this study special high lift rudder system equipped with the trailing edge rotor has been suggested in correspondence with the increasing requirement of greater rudder force. Through the numerical simulation it is cleared that the trailing edge rotor could play a role in enhancement of circulation and refinement of boundary layer of the rudder system. At the same time it is found out that the lift force of the rudder system without rotation of trailing edge rotor could be doubled when the circumferential velocity of the trailing edge rotor is equal to twice of the inflow velocity.

블레이드 하중이 축류형 팬에서의 팁 누설 유동구조에 미치는 영향 (Effect of Blade Loading on the Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.294-304
    • /
    • 2003
  • An experimental analysis using three-dimensional laser Doppler velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

종격동염과 동반된 결합조직염식도염의 치료 (Treatment of Phlegmonous Esophagitis Combined with Mediastinitis)

  • 이호석;박진수;김영대
    • Journal of Chest Surgery
    • /
    • 제40권10호
    • /
    • pp.711-714
    • /
    • 2007
  • 결합조직염식도염은 식도의 점막하층과 근육층의 세균감염에 의해 발생하며 드문 질환이며 높은 사망률을 보인다. 69세 남자가 7일간의 흉통과 발열을 주소로 내원하였다. 흉부전산화단층촬영에서 종격동의 확장, 식도 주행을 따라 있는 식도벽의 비후와 공기 음영, 우측 흉수가 관찰되었다. 환자는 우측 개흉술을 통해 배농, 죽은조직제거술, 천공된 식도 근육층의 1차 봉합술을 시행 받았다. 추가 수술은 없었으며 퇴원시 식도 누출과 연하장애 없이 경구 식이는 원활하였다.

FRP Confinement of Heat-Damaged Circular RC Columns

  • Al-Nimry, Hanan Suliman;Ghanem, Aseel Mohammad
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.115-133
    • /
    • 2017
  • To investigate the effectiveness of using fiber reinforced polymer (FRP) sheets in confining heat-damaged columns, 15 circular RC column specimens were tested under axial compression. The effects of heating duration, stiffness and thickness of the FRP wrapping sheets were examined. Two specimen groups, six each, were subjected to elevated temperatures of $500^{\circ}C$ for 2 and 3 h, respectively. Eight of the heat-damaged specimens were wrapped with unidirectional carbon and glass FRP sheets. Test results confirmed that elevated temperatures adversely affect the axial load resistance and stiffness of the columns while increasing their ductility and toughness. Full wrapping with FRP sheets increased the axial load capacity and toughness of the damaged columns. A single layer of the carbon sheets managed to restore the original axial resistance of the columns heated for 2 h yet, two layers were needed to restore the axial resistance of columns heated for 3 h. Glass FRP sheets were found to be less effective; using two layers of glass sheets managed to restore the axial load carrying capacity of columns heated for 2 h only. Confining the heat-damaged columns with FRP circumferential wraps failed in recovering the original axial stiffness of the columns. Test results confirmed that FRP-confining models adopted by international design guidelines should address the increased confinement efficiency in heat-damaged circular RC columns.

Surgical refinement of the purse-string suture for skin and soft tissue defects of the head and neck

  • Park, Hyochun;Lee, Yunjae;Yeo, Hyeonjung;Park, Hannara
    • 대한두개안면성형외과학회지
    • /
    • 제22권4호
    • /
    • pp.183-192
    • /
    • 2021
  • Background: The purse-string suture (PSS) is a simple and rapid wound closure method that results in minimal scarring. It has been used to treat circular or oval skin defects caused by tumor excision or trauma. However, due to obscurity, it is not widely used, especially for the head and neck. This study aimed to modify the PSS to obtain predictable and acceptable results. Methods: A total of 45 sites in 39 patients with various types of skin and soft tissue defects in the head and neck were treated with PSS. We used PDS II (2-0 to 5-0), which is an absorbable suture. Minimal dissection of the subcutaneous layer was performed. The suture knot was hidden by placing it in the dissection layer. Depending on the characteristics of the skin and soft tissue defects, additional surgical interventions such as side-to-side advancement sutures, double PSS, or split-thickness skin graft were applied. Results: All wounds healed completely without any serious complications. Large defects up to 45 mm in diameter were successfully reconstructed using only PSS. Postoperative radiating folds were almost flattened after approximately 1-2 months. Conclusion: PSS is simple, rapid, and relatively free from surgical design. Owing to the circumferential advancement of the surrounding tissue, PSS always results in a smaller scar than the initial lesion and less distortion of the body structures around the wound in the completely healed defect. If the operator can predict the process of healing and immediate radiating folds, PSS could be a favorable option for round skin defects in the head and neck.

횡방향 전단하중을 받는 단일방향 복합재료의 미시역학적 거동연구 (Micromechanical behavior of unidirectional composites under a transverse shear loading)

  • 최흥섭
    • 대한기계학회논문집A
    • /
    • 제21권11호
    • /
    • pp.1896-1911
    • /
    • 1997
  • Effects of fiber-matrix interphases on the micro-and macro-mechanical behaviors of unidirectionally fiber-reinforced composites subjected to transverse shear loading at remote distance have been studied. The interphases between fibers and matrix have been modeled by the spring-layer which accounts for continuity of tractions, but allows radial and circumferential displacement jumps across the interphase that are linearly related to the normal and tangential tractions. Numerical calculations for basic cells of the composites have been carried out using the boundary element method. For an undamaged composite the micro-level stresses at the matrix side of the interphase and effective shear stiffness have been computed as functions of fiber volume ratio $V_f$ and interphase stiffness k. Results are presented for various interphase stiffnesses from the perfect bonding to the case of total debonding. For a square array composite the results show that for a high interphase stiffness k>10, an increase of $V_f$ increases the effective transverse shear modulus G over bar of the composite. For a relatively low interphase stiffness k<1, it is shwon that an increase of $V_f$ slightly decreases the effective transverse shear modulus. For the perfect bonding case, G over bar for a hexagonal array composite is slightly larger than that for a square array composite. Also for a damaged composite partially debonded at the interphase, local stress fields and effective shear modulus are calculated and a decrease in G over bar has been observed.

CERAMOGRAPHY ANALYSIS OF MOX FUEL RODS AFTER AN IRRADIATION TEST

  • Kim, Han-Soo;Jong, Chang-Yong;Lee, Byung-Ho;Oh, Jae-Yong;Koo, Yang-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.576-581
    • /
    • 2010
  • KAERI (Korea Atomic Energy Research Institute) fabricated MOX (Mixed Oxide) fuel pellets as a cooperation project with PSI (Paul Scherrer Institut) for an irradiation test in the Halden reactor. The MOX pellets were fitted into fuel rods that included instrumentation for measurement in IFE (Institutt for Energiteknikk). The fuel rods were assembled into the test rig and irradiated in the Halden reactor up to 50 MWd/kgHM. The irradiated fuel rods were transported to the IFE, where ceramography was carried out. The fuel rods were cut transversely at the relatively higher burn-up locations and then the radial cross sections were observed. Micrographs were analyzed using an image analysis program and grain sizes along the radial direction were measured by the linear intercept method. Radial cracks in the irradiated MOX were observed that were generally circumferentially closed at the pellet periphery and open in the hot central region. A circumferential crack was formed along the boundary between the dark central and the outer regions. The inner surface of the cladding was covered with an oxide layer. Pu-rich spots were observed in the outer region of the fuel pellets. The spots were surrounded by many small pores and contained some big pores inside. Metallic fission product precipitates were observed mainly in the central region and in the inside of the Pu spots. The average areal fractions of the metallic precipitates at the radial cross section were 0.41% for rod 6 and 0.32% for rod 3. In the periphery, pore density smaller than 2 ${\mu}m$ was higher than that of the other regions. The grain growth occurred from 10 ${\mu}m$ to 12 ${\mu}m$ in the central region of rod 6 during irradiation.

내측원관이 회전하는 동심이중원관 사이의 난류 쿠에트 유동에 관한 연구 (Turbulent Couette Flow between Coaxial Cylinders with Inner Cylinder Rotating)

  • 김광용;김진욱;조용철
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.540-546
    • /
    • 1992
  • 본 연구에서는 레이놀즈응력 모델이 곡률효과에 대한 추가적인 수정을 요구하 는 지를 알기 위하여 유선곡률에 의해 영향을 받는 원형 쿠에트 유동에 대해 수치계산 을 수행하고, 이 결과를 측정한 실험치와 비교하였다. 본 연구의 실험에서는 완전 난류 영역에서 난류평균속도와 난류응력성분들을 측정하였다. 수치계산에 있어서는 레이놀즈응력 모델에 대하여 Gibson과 Younis가 곡률효과를 고려해 제안한 새로운 모 델상수를 기존의 모델상수와 함께 적용하여 그 결과를 비교하였다. 계산된 결과를 본 실험의 측정치와 아울러 함께 Smith와 Townsend의 측정치와도 비교하였다.

Characteristics of wind loading on internal surface and its effect on wind-induced responses of a super-large natural-draught cooling tower

  • Zou, Yun-feng;Fu, Zheng-yi;He, Xu-hui;Jing, Hai-quan;Li, Ling-yao;Niu, Hua-wei;Chen, Zheng-qing
    • Wind and Structures
    • /
    • 제29권4호
    • /
    • pp.235-246
    • /
    • 2019
  • Wind loading is one of important loadings that should be considered in the design of large hyperbolic natural-draught cooling towers. Both external and internal surfaces of cooling tower are under the action of wind loading for cooling circulating water. In the previous studies, the wind loads on the external surface attracted concernedly attention, while the study on the internal surface was relatively ware. In the present study, the wind pressure on the internal surface of a 220 m high cooling tower is measured through wind tunnel testing, and the effect of ventilation rate of the packing layer on internal pressure is a major concern. The characteristics of internal wind pressure distribution and its effect on wind-induced responses calculated by finite element method are investigated. The results indicate that the wind loading on internal surface of the cooling tower behaves remarkable three-dimensional effect, and the pressure coefficient varies along both of height and circumferential directions. The non-uniformity is particularly strong during the construction stage. Analysis results of the effect of internal pressure on wind-induced responses show that the size and distribution characteristics of internal pressure will have some influence on wind-induced response, however, the outer pressure plays a dominant role in the wind-induced response of cooling tower, and the contribution of internal pressure to the response is small.

Smear layer 처리에 따른 미세누출에 대한 연구 (THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE)

  • 이정민;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.378-389
    • /
    • 2006
  • 본 연구는 도말층 제거 여부에 따른 근관 밀폐효과를 평가하기 위해 단근관 치아를 3% NaOCl 하에서 Ni-Ti file을 이용하여 crown-down법으로 근관 형성 후 최종세정제로 NaOCl을 사용한 군과 EDTA를 사용한 군, 6개월 보관한 NaOCl-6군과 EDTA-6군으로 분류하였다. Continuous wave법으로 근관 충전 시행 후 색소 침투를 시행한 다음 해부학적 근첨에서 1.5 mm (Level 1), 3.0 mm (Level 2), 4.5 mn (Level 3)에서 수평절단 하여 누출률을 측정하였다. 1. 모든 실험군에서 평균 누출률은 치근단부에서 치경부로 갈수록 감소하였다. 2. NaOCl군의 누출률이 EDTA 군보다 level 1 2, 3에서 높게 나타났으나 level 1에서만 통계학적 유의차를 보였다 (p < 0.05). 3. NaOCl-6군의 누출률이 EDTA-6 군보다 Level 1, 2, 3에서 높게 나타났으나 level 1에서만 통계학적 유의차를 보였다 (p < 0.05). 4. NaOCl-6군의 누출률이 NaOCl군에 비해 Level 1, 2, 3에서 증가하였으나 level 1에서만 통계학적 유의차를 보였다 (p < 0.05). 5. EDTA-6군의 누출률이 EDTA 군에 비해 Level 1, 2, 3에서 증가하였으나 통계학적 유의차는 없었다. 6. 주사전자현미경 관찰 결과 NaOCl 군과 NaOCl-6 군은 도말층이 제거되지 않아 상아세관내로 sealer 및 근관충전재가 침투하지 못한 반면, EDTA 군과 EDTA-6 군에서는 도말층이 제거되고 상아세관내로의 sealer와 근관충전재의 침투가 관찰되었다. 이상의 연구결과 EDTA를 이용하여 도말층을 제거한 경우 근관충전 즉시와 6개월 후 치근단 1/3 부위의 근단부 미세누출을 감소시킬 수 있을 것으로 사료된다.