• 제목/요약/키워드: circulation fan

검색결과 55건 처리시간 0.026초

Experimental research on the mechanisms of condensation induced water hammer in a natural circulation system

  • Sun, Jianchuang;Deng, Jian;Ran, Xu;Cao, Xiaxin;Fan, Guangming;Ding, Ming
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3635-3642
    • /
    • 2021
  • Natural circulation systems (NCSs) are extensively applied in nuclear power plants because of their simplicity and inherent safety features. For some passive natural circulation systems in floating nuclear power plants (FNPPs), the ocean is commonly used as the heat sink. Condensation induced water hammer (CIWH) events may appear as the steam directly contacts the subcooled seawater, which seriously threatens the safe operation and integrity of the NCSs. Nevertheless, the research on the formation mechanisms of CIWH is insufficient, especially in NCSs. In this paper, the characteristics of flow rate and fluid temperature are emphatically analyzed. Then the formation types of CIWH are identified by visualization method. The experimental results reveal that due to the different size and formation periods of steam slugs, the flow rate presents continuous and irregular oscillation. The fluid in the horizontal hot pipe section near the water tank is always subcooled due to the reverse flow phenomenon. Moreover, the transition from stratified flow to slug flow can cause CIWH and enhance flow instability. Three types of formation mechanisms of CIWH, including the Kelvin-Helmholtz instability, the interaction of solitary wave and interface wave, and the pressure wave induced by CIWH, are obtained by identifying 67 CIWH events.

대기온도 변화에 따른 150 MW 화력발전소용 공랭식 복수기 송풍기수 선정 (Selection of Number of Fans in an Air-Cooled Condenser of a 150 MW Thermal Power Plant according to Ambient Air Temperature)

  • 황용훈;허기무;윤성훈;문윤재;이재헌;문승재
    • 플랜트 저널
    • /
    • 제10권4호
    • /
    • pp.24-28
    • /
    • 2014
  • 본 연구에서는 150 MW 화력발전소를 기준하여 발전소 건설지역의 최저 대기온도 $-17.1^{\circ}C$부터 최대 대기온도 $36.7^{\circ}C$까지를 $3^{\circ}C$의 일정한 간격으로 구분하여 복수기 압력이 증기터빈의 배압조건을 만족하는 대기온도별 송풍기 수량을 검토하였다. 공랭식 복수기는 대기온도 및 송풍기 운전수량 변화에 따른 냉각공기 순환량에 영향을 받아 운전조건이 변경이 되므로, 대기온도가 복수기 설계기준온도 이상의 경우에는 공랭식 복수기 송풍기의 운전수량을 최대로 해야 하고, 대기온도가 복수기 설계기준온도 미만의 경우에는 증기터빈 배압 운전조건을 만족하는 범위 내에서 송풍기 운전수량을 변화시켜 공랭식 복수기에 가해지는 공기 순환량을 감소시키는 것이 안정적인 발전소 운영을 하는 것임을 확인하였다.

  • PDF

자갈축열층의 공기유동 및 축열성능 (The Fluid Flow and Heat Storage Performance in Thermal Storage Bed using Gravel)

  • 이종원
    • 한국농공학회논문집
    • /
    • 제56권3호
    • /
    • pp.75-81
    • /
    • 2014
  • Fossil energy is needed for a whole year greenhouse cropping due to climate in South Korea. Because the most of the fossil energy resources is imported, it is necessary to develop technology to be able to reduce the energy cost in order to manage greenhouse profitably. The greenhouse commonly consume less amount of energy as compared to other industrial sectors. Replacement of fossil fuel with solar thermal storage, therefore, can be an economical as well as environmentally sustainable option for greenhouse heating. The fluid flow, heat storage and radiation characteristic of the gravel bed model were analyzed to provide basic data for design of the experimental solar heated greenhouse with underground thermal storage using gravel. The air flow velocity in the gravel storage bed was proven to be affected from the capacity of circulation fan and the circulation method and the positive pressure method was proven to be the best among the different air circulation methods. The initial air temperature of the thermal storage bed of 1.2 m $wide{\times}9$ m $long{\times}0.9$ m deep was $10^{\circ}C$. After the thermal storage bed is heated by air of the mean temperature $4^{\circ}C$ during 9 hours, the temperature has increased about $20.3^{\circ}C$ and the storage of heat was about 33,000 kcal. The important factors should be taken into consideration for design of the solar heated greenhouse with underground thermal storage using gravel are insulation of rock storage, amount of storing heat, inflow rate and direction of inlet and outlet duct.

고압가스 냉각시스템의 특성 연구 (A Study on Quenching Characteristics of a High Pressure Gas Quenching System)

  • 김한석;안국영;이상민;장병록
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.11-19
    • /
    • 2004
  • An Experimental study on the characteristics of high pressure gas quenching system was carried out in the present study. The characteristics of gas quenching system have been studied with high pressure gas chamber and specimen for various gas pressure and velocity which are the design parameter of quenching system. The quenching gas was used compressed air which properties are very similar with Nitrogen gas usually used in industrial gas quenching system. The result shows that the quenching rate of mid surface of specimen is lower than each ends of them which are close to low temperature quenching surface. And to increases the quenching intensity, the increment of quenching gas pressure is more efficient than the increment of quenching gas velocity at the point of reducing the circulation fan power.

  • PDF

배풍열 회수장치를 이용한 고추의 건조특성에 관한 연구 (Drying Characteristics of Red Pepper using Exhaust Heat Recovery System)

  • 백이;조기현;정형길
    • 한국산업융합학회 논문집
    • /
    • 제6권2호
    • /
    • pp.103-108
    • /
    • 2003
  • This study was performed to find out drying characteristics and develop waste heat recovery dryer. this system was initiated in order to recover discharged waste heat of drying air from drying chamber in agricultural products dryer and recycle for additional heat source that could save drying cost. The system consists of drying chamber, fan, burner, circulation pump and heat exchanger made of fins and tubes. For the system performance, drying experiments with fresh pepper were conducted, and comparisons on fuel consumption amount and drying performance were made between conventional dryer and the heat recovery system attached dryer.

  • PDF

HVDC 시스템의 수냉식 냉각 시스템 (Water-Cooling System of HVDC System)

  • 김찬기
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.257-267
    • /
    • 1999
  • 본 논문은 대용량 컨버터의 수냉식 방열 시스템에 관한 내용을 담고 있다. 본 논문은 수냉식 방열 시스템의 이론적 근거와 모델링을 제시하고 전력용 반도체(싸이리스터)의 열량 계산을 수학적인 모델링에 근거하여 제시하였으며 실제로 우리나라에 설치되어 있는 제주-해남 HVDC 시스템에 적용하여 타당성을 검증하였다.

  • PDF

난황유와 공기순환팬의 상추 흰가루병 방제효과 및 생산에 미치는 영향 (Effect of COY (Cooking Oil and Yolk mixture) and ACF (Air-circulation Fan) on Control of Powdery Mildew and Production of Organic Lettuce)

  • 지형진;류경열;박종호;최두회;류갑희;류재기;신순선
    • 식물병연구
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2008
  • Podosphaera fusca에 의한 상추 흰가루병은 최근에 보고된 새로운 병해이나 심하게 발생될 경우에는 수량을 50% 이상 감소시켜 유기농 상추재배에 큰 위협요인 되고 있다. 본 연구에서는 비닐하우스 내부에 소형의 공기순환팬을 6 m 간격으로 설치하여 상추 주변의 기상환경을 개선한 결과 수량 57% 증가와 정식묘 고사율 71.4% 감소 효과를 얻었다. 공기순환팬을 설치한 하우스에서 식용유를 계란노른자로 유화시킨 난황유 0.3% 용액을 처리한 경우에는 농가 관행재배 하우스에 비해 묘 고사율은 $89.3{\sim}92.9%$ 감소되었고 상추 흰가루병 방제효과는 89.6-96.3%로 매우 높게 나타나 살균제(azoxystrobin)와 대등하였다. 난황유 처리구별로 상추 수량은 $23.3{\sim}26.5\;kg$으로 대조 하우스의 11.86 kg과 비교할 때 약 2배 정도 높았고 상추 잎의 경도는 다소 낮고 엽록소 함량은 높아지는 등 상추 품질을 개선하는 효과도 나타났다. 본 연구 결과를 볼 때 채종유를 계란노른자로 유화시켜 만든 난황유는 상추 흰가루병 방제효과가 매우 높고 유기농 상추 생산에 유용하게 활용할 수 있을 것으로 기대되는데 공기순환팬을 설치하여 재배환경을 개선하면 상승효과를 얻을 수 있는 것으로 나타났다.

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

해군 함정 VRTU의 과열방지를 위한 열전소자 냉각장치의 적용에 따른 기관실 및 VRTU 내부 열 유동특성 분석 (An Analysis of the Thermal Flow Characteristics in Engine-Room and VTRU in accordance with Application of Thermoelectric Device Cooling System to Prevent Overheating of the Korean Navy Ship VRTU)

  • 정영인
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.610-616
    • /
    • 2020
  • 본 연구에서는 대한민국 해군 함정의 하절기 운용 및 적도지병 파병 간 발생하고 있는 VRTU 과열로 인한 고온경보 발생과 장비정지 발생현상을 해결하기 위하여 해군 군수사령부 함정기술연구소와 공동연구를 수행하였다. 열전소자 냉각장치 설치에 따른 냉각효과를 확인하고, 전산 열 유동해석을 수행하여 VRTU 내부 열 유동특성을 분석하였다. 또 해석을 통해 기관실(디젤엔진룸) 내부의 온도분포를 살펴보고 VRTU 과열방지를 위한 최적의 설치위치를 알아보았다. 분석결과, 냉각장치를 설치함에 따라 VRTU 내부 평균 체적온도가 약 10 ℃ 감소하는 것을 확인하였으며 냉각장치에 설치된 Fan은 열 순환을 원활하게 하여 냉각효과를 높였다. 기관실 내부는 디젤엔진 상부에서 높은 온도분포를 나타냈고 통풍관 디퓨저 하부에서 가장 낮은 온도분포를 보였다. 열전소자 냉각장치는 높은 냉각성능을 나타내었으며, VRTU는 과열방지를 위하여 기관실의 통풍관 디퓨저 하부에 설치하는 것이 적절할 것으로 판단된다.

시설하우스 온도 조절을 위한 수직형 교반 히터 자동제어 시스템 (Automatic Control System of Vertical Agitation Heater for Controlling Temperature of Greenhouse)

  • 곽연아;박경욱;김응곤
    • 한국전자통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.623-628
    • /
    • 2015
  • 현재의 시설하우스에서의 난방 방식은 한 곳에 고정되어져서 위치에 따른 온도 편차가 심해 질 수밖에 없는 실정이다. 채소나 과일 작물 등을 재배하는 시설하우스는 적정 온도의 유지가 필수적인데 하우스 내부의 상하 온도 차이로 인해 적정 난방 또는 냉방을 위한 에너지 소모가 많다. 본 논문에서는 하우스 내부의 공기 순환을 효율적으로 할 수 있는 새로운 형태의 난방 방식인 수직형 교반 히터 자동 제어 시스템을 제안한다. 시설하우스 상 하부의 온도를 이용하여 수직형 교반 히터의 공기 순환 팬과 히팅을 상황에 맞게 독립적으로 제어함으로써 최소한의 전기 소비로 난방의 효율을 극대화 시켜 계획 가능한 작물 생산과 난방비 절감이 가능하다.