• Title/Summary/Keyword: circuit-level model

Search Result 167, Processing Time 0.038 seconds

An Implementation of the switch-Level Fault Simulator for CMOS Circuits with a Gate-to-Drain/Source short Fault (게이트와 드레인/소오스 단락결함을 갖는 CMOS 회로의 스위치 레벨 결함 시뮬레이터 구현)

  • 정금섭;전흥우
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.116-126
    • /
    • 1994
  • In this paper, the switch-level fault simulator for CMOS circuits with a gate-to-drain/source short fault is implemented. A fault model used in this paper is based on the graphical analysis of the electrical characteristics of the faulty MOS devices and the conversion of the faulty CMOS circuit to the equivalent faulty CMOS inverter in order to find its effect on the successive stage. This technique is very simple and has the increased accuracy of the simulation. The simulation result of the faulty circuit using the implemented fault simulator is compared with the result of the SPICE simulation.

  • PDF

A Hierarchical Test Generation for Asynchronous Circuits

  • Eunjung Oh;Kim, Soo-Hyun;Lee, Dong-Ik;Park, Ho-Yong
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1968-1971
    • /
    • 2002
  • In this paper, we have presented a test- ing method for a kind of asynchronous circuits. Tar- get circuit model is the 3D machine that is one of the most successful implementation of extended burst-mode (XBM) machines. We present a high-level test generation method for the 3D machine using the specification of the circuit. We also present a gate-level test pattern generation method using a synchronous test pattern generator. Experimental results show that the combination of the above two methods achieves high fault coverage over 3D machines and saves test generation time.

  • PDF

The oscillation conduction characteristics of ZnO varistor fabricated with 3-composition seed grain method (3-성분 종입자법으로 제조한 저전압 ZnO 바리스터의 발진 전도특성)

  • 장경욱;김영천;황석영;김용주;이준웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1019-1026
    • /
    • 1996
  • In this study, we may be presented the carrier oscillation properties for the low-voltage varistor fabricated by a new method of three composition seed grain, in order to analyze the behavior of carriers at the its equivalent circuit model. The oscillation phenomena of carriers appeared from current-voltage characteristics under knee voltage is shown by the transient flow of nontrapped carriers group in the trap level of intergranular layer, surface state and/or depletion layer. In particularly, current oscillation phenomena is hardly shown in the high electric field. It is that the injected carriers from both electrodes are directly from the conduction band of forward biased ZnO grain through the intergranular layer into the reverse biased ZnO grain, because the trap level in the electric field above the knee voltage is mostly filled.

  • PDF

Switching Pattern-Independent Simulation Model for Brushless DC Motors

  • Kang, Yong-Jin;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.173-178
    • /
    • 2011
  • In order to verify the performance of brushless DC (BLDC) motors, the simulation method has been widely used. The current of a BLDC motors flows on two phase windings to obtain a constant torque. However, the freewheeling current caused by the inductance component of a BLDC motor exists at the commutation point so that the current can flow on three phase windings at the same time. Due to the changes of the excited phases, the model equations are frequently changed during BLDC motor drive operation. The model equations can be also changed by the applied switching pattern since the current path in the inverter circuit changes according to switching pattern. A BLDC motor system can utilize various switching patterns for many different purposes. However, such changes of the model equations complicate the simulation procedure. In this paper, the technique to set up model equations is proposed to ease the simulation of a BLDC motor system through an inverter circuit analysis. The proposed technique will be verified using the C language. Although this method does not provide the level of detail obtainable from commercial simulation tools like PSIM or SIMULINK, it can provide an efficient way to quickly compare various conditions.

In-situ Blockage Monitoring of Sensing Line

  • Mangi, Aijaz Ahmed;Shahid, Syed Salman;Mirza, Sikander Hayat
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.98-113
    • /
    • 2016
  • A reactor vessel level monitoring system measures the water level in a reactor during normal operation and abnormal conditions. A drop in the water level can expose nuclear fuel, which may lead to fuel meltdown and radiation spread in accident conditions. A level monitoring system mainly consists of a sensing line and pressure transmitter. Over a period of time boron sediments or other impurities can clog the line which may degrade the accuracy of the monitoring system. The aim of this study is to determine blockage in a sensing line using the energy of the composite signal. An equivalent Pi circuit model is used to simulate blockages in the sensing line and the system's response is examined under different blockage levels. Composite signals obtained from the model and plant's unblocked and blocked channels are decomposed into six levels of details and approximations using a wavelet filter bank. The percentage of energy is calculated at each level for approximations. It is observed that the percentage of energy reduces as the blockage level in the sensing line increases. The results of the model and operational data are well correlated. Thus, in our opinion variation in the energy levels of approximations can be used as an index to determine the presence and degree of blockage in a sensing line.

Comparison of Various Methods to Mitigate the Flicker Level of DFIG in Considering the Effect of Grid Conditions

  • Kim, Yun-Seong;Marathe, Aditya;Won, Dong-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.612-622
    • /
    • 2009
  • The short circuit ratio (SCR) of a given grid is able to show the stability of the system in the case of unwanted elements, such as wind turbulence. This paper presents the simulation of a model of the doubly fed induction generator in the simulation software PSCAD/EMTDC. This model has been used to study flicker during continuous operation and the effect of SCR and grid impedance angle on flicker emission. Simulation results show that compensation of the stator reactive power is an effective method to considerably reduce the flicker levels, irrespective of the grid conditions.

A Coupled Circuit and Field Analysis of a Stand-Alone Permanent-Magnet Synchronous Generator with Inset Rotor

  • Chan T. F.;Yan Lie-Tong;Lai L. L.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.253-257
    • /
    • 2005
  • By using a coupled circuit, time-stepping, two-dimensional finite element method (2-D FEM), the performance of a stand-alone permanent-magnet synchronous generator (PMSG) with inset rotor can be computed without involving the classical two-axis model. The effects of interpolar air gap length and armature resistance on the load characteristics are investigated. It is shown that the interpolar flux density, and hence the amount of voltage compensation, is affected by magnetic saturation. Validity of the coupled circuit and field analysis is confirmed by experiments on a prototype generator. The machine exhibits an approximately level load characteristic when it is supplying an isolated unity-power-factor load.

The variable hysteresis modeling circuit for spintronic device (자성반도체의 가변 히스테리시스 특성 모델링 회로)

  • Hwang WonSeok;cho Chung-Hyun;kim Bumsoo;Lee GabYong;Lee ChangWoo;Kim Dong Myong;Min Keung-Sik;Kim Daejeong
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.447-450
    • /
    • 2004
  • The modeling circuit becomes more important in developing various magnetic devices regarding the fact that the competitive architecture and circuitry should be developed simultaneously. In this paper, we introduce a modeling circuit for hysteresis characteristic of a magnetic device, which is a major characteristic in the spin dependent magnetic material. This transistor-level model is conspicuous in that it can be usefully embodied in real circuits rather than conventional SPICE models are only for simulations.

  • PDF

Multi-mode noise reduction of using piezoelectric shunt damping smart panels (압전션트를 이용한 패널의 다중 모드 소음 저감에 관한 연구)

  • Kim, Joon-Hyoung;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.216-221
    • /
    • 2002
  • In this paper, the transmitted noise reduction of smart panels of which passive piezoelectric shunt damping is used, is experimentally studied. Shunt damping experiments are based on the measured electrical impedance model. A passive shunt circuit composed of inductors, and a load resistor is devised to dissipate the maximum energy into the joule heat energy. For multi-mode shunt damping, the shunt circuit is redesigned by adding a blocking circuit. Also the optimal location of the piezoelectric patch is studied by FEM in order to cause the maximum admittance from the patch for each mode of aluminum plate. In results, the transmitted sound pressure level of panels is efficiently reduced for multi-modes

  • PDF

Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.