• Title/Summary/Keyword: chromium ($Cr^{3+}$

Search Result 461, Processing Time 0.029 seconds

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

Influence of Fly Ash Application on Content of Heavy Metal in the Soil II. Content Change by the Successive Application (석탄회(石炭灰) 시용(施用)이 토양중(土壤中) 중금속(重金屬) 함량(含量)에 미치는 영향(影響) II. 운용(連用)에 따른 함량변화(含量變化))

  • Kim, Bok-Young;Lim, Sun-Uk;Park, Jong-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.2
    • /
    • pp.72-77
    • /
    • 1994
  • This study was conducted to investigate the influence of treatment of fly ash on heavy metal contents of the arable soil. Rice was cultivated on the two types of paddy field clay loam and sandy loam with 0, 12ton/10a of anthracite fly ash and bituminous coal fly ash application. And soybean was cultivated at the same type of upland fields with those ashes of 0, 9ton/10a, yearly for three years. At the harvest time, the heavy metal contents in the different layer were investigated. The results were summarized as follows : 1. The contents of some heavy metal were increased in the surface soils but didn't show the tendency in the deeper layer or soil texture. 2. In the paddy fields, the contents of Cd, Cu, Zn, Cr were increased. Meanwhile and the upland fields, the contents of Cd and Cr were increased with the successive application of Anthracite fly ash, but the others didn't show those tendency. 3. The contents of Cd, Cu and Zn in the paddy field, were increased but the upland field, the contents of Cd, Cr and Ni were increased by the successive application of bituminous coal fly ash.

  • PDF

MECHANICAL PROPERTIES OF LASER WELDED Co-Cr ALLOY (레이저 융합된 Co-Cr 합금의 물리적 성질에 관한 연구)

  • Bae Ki-Chang;Woo Yi-Hyung;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.440-450
    • /
    • 2003
  • Statement of problem : The joints of removable partial denture alloys have failed frequently after routine usage. Purpose : The purpose of this study was to evaluate the mechanical properties of the laser welded Co-Cr alloys. Material and method : For this study 20 Co-Cr specimens were casted and 10 of them were seperated on the middle area and laser welded with Alpha laser welding machine(Siro Lasertec, Pforzheim, Germany). Rest of them which were as cast, were used as a control group. For the section of the experimental specimens, wire cutting machine was used to make a even gap of the all specimens. Laser welding was done with manufacturer's instrunction and tested each specimen by Instron Machine. Tensile strength, 0.2% yield strength and % elongations were recorded. Fractured surfaces were investigated with SEM. Results : The results were as follows : 1. The tensile strength of the laser welded group(617.7MPa) was about 75% of the as cast group(820.4MPa). It had stastically significant differences(p<0.05). 2. The % elongation of the experimental group was 6.6 which was lower than the control group(14.3). 3. Fracture of the experimental group occured in the welded surface and showed many voids. In contrast, the fracture surface of the control group was showed rough surfaces without any voids. Conclusion : The tensile strengths of the as-cast joints were higher than those for the laser welded joints, and the % elongation of the experimental group was lower than the control group. Porosity was found in laser-welded joints.

Effect of Intermediate Layer Coated Diamond Particles on Performance of Diamond Tool (다이아몬드 입자에 형성된 중간층이 다이아몬드 공구 성능에 미치는 영향)

  • Son, Kyung-Sik;Lee, Jung-Hoon;Choi, Yong-Je;Jung, Uoo-Chang;Chung, Won-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.5
    • /
    • pp.216-222
    • /
    • 2013
  • In order to improve the performance of electrodeposited diamond-nickel composite, surface modification of diamond particles was carried out using powder immersion reaction assisted coating (PIRAC). Titanium and chromium were selected as coating elements, which are known as carbide former. With respect to the powder elements, various phases were formed on diamond; metallic Ti and TiC for Ti powder, $Cr_3C_2$ for Cr powder, and TiC and $Cr_3C_2$ for Ti-Cr mixed powder. Surface modified diamond particle showed higher specific surface area, especially Ti coating induced considerable increase of specific surface area. The increase of specific surface area suggests increase of surface roughness, and that was confirmed by surface observation using FE-SEM. In addition, wear properties of diamond-nickel composite including surface modified diamonds were improved, and Ti coated diamond showed the highest performance. The wear property of diamond-nickel composite is dependent on adhesion strength between diamond particle and nickel layer. Therefore, surface modification of diamond particle by PIRAC increasing surface roughness is effective to improve the properties of diamond-nickel composite.

Chemical Properties of Indoor Individual Particles Collected at the Daily Behavior Spaces of a Factory Worker

  • Ma, Chang-Jin;Kang, Gong-Unn;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.2
    • /
    • pp.122-130
    • /
    • 2017
  • The main purpose of the study was to clarify the properties of individual particles collected at each behavior space of a factory worker. The samplings of size-segregated ($PM_{2.1-1.1}$ and $PM_{4.7-3.3}$) indoor particles were conducted at three different behavior spaces of a factory worker who is engaged in an auto parts manufacturing plant (i.e., his home, his work place in factory, and his favorite restaurant). Elemental specification (i.e., relative elemental content and distribution in and/or on individual particles) was performed by a micro-PIXE system. Every element detected from the coarse particulate matters of home was classified into three groups, i.e., a group of high net-counts (Na, Al, and Si), a group of intermediate net-counts (Mg, S, Cl, K, and Ca), and a group of minor trace elements (P, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, and Pb). The results of EF for $PM_{4.7-3.3}$ in home indicated that several heavy metals were generated from the sources within the house itself. An exceptional feature shown in the individual particles in workplace is that Cr, Mn, and Co were clearly detected in both fine and coarse particles. Cluster analysis suggested that the individual coarse particles ($PM_{4.7-3.3}$) collected at the indoor of factory were chemically heterogeneous and they modified with sea-salt, mineral, and artificially derived elements. The principal components in individual coarse particles collected at restaurant were sea-salt and mineral without mixing with harmful trace elements like chromium and manganese. Compared to the indoor fine particles of home and restaurant, many elements, especially, Cl, Na, Cr, Mn, Pb, and Zn showed overwhelmingly high net-counts in those of factory.

Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires

  • Arici, Nursel;Akdeniz, Berat S.;Oz, Abdullah A.;Gencer, Yucel;Tarakci, Mehmet;Arici, Selim
    • The korean journal of orthodontics
    • /
    • v.51 no.4
    • /
    • pp.270-281
    • /
    • 2021
  • Objective: The aim of this in vitro study was to evaluate the changes in friction between orthodontic brackets and archwires coated with aluminum oxide (Al2O3), titanium nitride (TiN), or chromium nitride (CrN). In addition, the resistance of the coatings to intraoral conditions was evaluated. Methods: Stainless steel canine brackets, 0.016-inch round nickel-titanium archwires, and 0.019 × 0.025-inch stainless steel archwires were coated with Al2O3, TiN, and CrN using radio frequency magnetron sputtering. The coated materials were examined using scanning electron microscopy, an X-ray diffractometer, atomic force microscopy, and surface profilometry. In addition, the samples were subjected to thermal cycling and in vitro brushing tests, and the effects of the simulated intraoral conditions on the coating structure were evaluated. Results: Coating of the metal bracket as well as nickel-titanium archwire with Al2O3 reduced the coefficients of friction (CoFs) for the bracket-archwire combination (p < 0.01). When the bracket and stainless steel archwire were coated with Al2O3 and TiN, the CoFs were significantly lower (0.207 and 0.372, respectively) than that recorded when this bracket-archwire combination was left uncoated (0.552; p < 0.01). The friction, thermal, and brushing tests did not deteriorate the overall quality of the Al2O3 coatings; however, some small areas of peeling were evident for the TiN coatings, whereas comparatively larger areas of peeling were observed for the CrN coatings. Conclusions: Our findings suggest that the CoFs for metal bracket-archwire combinations used in orthodontic treatment can be decreased by coating with Al2O3 and TiN thin films.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Heavy Metals in Paddy Soil of Korea (우리나라 논 토양중(土壤中) 중금속(重金屬) 자연함량(自然含量))

  • Kim, Bok-Young;Jung, Beung-Kan;Choi, Jeong-Weon;Yun, Eul-Soo;Choi, Sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.4
    • /
    • pp.295-300
    • /
    • 1995
  • In order to find out the natural content of heavy metals(Cd, Cu, Pb, Zn, Cr, Ni)in paddy soil of Korea, a total of 1,196 soil samples of 15cm top layers all over the country 1995 were collected and analyzed. The average heavy metal contents in soils were 0.133mg/kg of Cd, 4.52mg/kg of Cu, 4.62mg/kg of Pb, 3.90mg/kg of Zn, 0.362mg/kg of Cr and 1.38mg/kg of Ni. These results are similar to the results of survey conducted in 1981.

  • PDF

A study on heavy metal concentration of cosmetics on the market (국내 시판중인 일부 화장품의 중금속 농도에 관한 연구)

  • Lee, Hun;Yoo, Yoo-Jung;Park, Myoung-Hee;Kim, Jung-Ho;Lee, Yong-Hee;Moon, Chan-Seok;Hwang, Yong-Shik;Moon, Deog-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.666-679
    • /
    • 1998
  • This study aims at providing the fundamental data on the field of cosmetics by comparing heavy metal concentration in terms of domestic/foreign products, items, companies and colors. This study has determined the concentration of chromium, lead, mangagnese, nickel, copper and vanadium in cosmetics such as moisturizer, concealer, foundation (Ivory-yellow), compact powder (Ivory-yellow), lip colo. (Red, brown), eye shadow (Red, brwon and dark green) and eye liner (Black) manufactured by five domestic cosmetic companies and five foreign cosmetic companies on the market. The samples have been collected in cosmetic stores in Pusan from Dec. lst 1996 to Jan. 3lst 1997. The results are as follows : 1. The heavy metal concentration in cosmetics was $2.420{\mu}g/g$ for chromium, $0.82{\mu}g/g$ for lead, $4.49{\mu}g/g$ for manganese, $1.69{\mu}g/g$for nickel, $0.53{\mu}g/g$ for copper, and $51{\mu}g/g$ for vanadium, respectively. 2. Lead and vanadium concentration were significantly higher in domestic cosmetics than foreign cosmetics(p<0.05). 3. The mean(GM) concentrations of heavy metal were different significantly (p<0.01) when classified with cosmetic items. The highest means shown at eye shadow in $Cr(14.96{\mu}g/g),\;Cu(1.32{\mu}g/g),\;V(1.28{\mu}g/g),\;and\;Ni(8.30{\mu}g/g)$, compact powder in $Pb(2.50{\mu}g/g)$, eye liner in $Mn(90.62{\mu}g/g)$. 4. The mean(GM) concentrations of heavy metal were different significantly (p<0.01) among colored cosmetics. The highest mean concentration of Cr, Ni, Cu and V were dark green-colored cosmetics, that of Mn was black-colored cosmetics, and that of Pb was ivory yellow- colored cosmetics.

  • PDF

Oxidation of STS304 Stainless Steel between 1050 and 1200℃ for 1 Hour in Air (STS 304 스테인리스강의 대기중 1050~1200℃, 1시간 동안의 산화)

  • Nguyen, Thuan Dinh;Lee, Dong Bok
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.4
    • /
    • pp.235-241
    • /
    • 2009
  • The STS304 stainless steel was oxidized isothermally and cyclically at temperatures between 1050 and $1200^{\circ}C$ for 1 hr in air. During isothermal oxidation, it displayed good oxidation resistance at $1050^{\circ}C$. However, it suffered from breakaway oxidation above $1100^{\circ}C$, being accompanied with internal oxidation. During cyclic oxidation, it also displayed good oxidation resistance at $1050^{\circ}C$, but it suffered from massive weight loss above $1125^{\circ}C$. The oxide scales formed consisted primarily of $Fe_2O_3$, $Fe_3O_4$ with and without $Cr_2O_3$. They were generally non-adherent.