• Title/Summary/Keyword: chromaticity

Search Result 667, Processing Time 0.035 seconds

Development of a Portable Colorimeter (소형 칼라미터의 개발에 관한 연구)

  • 김재형;황정연;서대식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

Analysis of Requirements for Night Vision Imaging System (야시조명계통 요구도 분석)

  • Kwon, Jong-Kwang;Lee, Dae-Yearl;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

The Variation in Chromaticity of Optical System having the Truncated Incident Beam (입사광의 단락된 정도에 따른 광학계의 색도 변화)

  • Park, Seong Jong;Chung, Chang Sub;Sim, Sang Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • In this paper, we use the C light which is a daylight and consider the incident beam having the Gaussian amplitude. We investigated the illuminance distributions and the variation in chromaticity of optical system having the truncated Gaussian amplitude on the focal plane and along the optical axis using the C light source. We also use the three sensitivity functions of human eye(CIE 1931) for wavelengths which are from 380nm to 780nm. When the truncation grade of incident beam having Gaussian amplitude decreases, the size of central spot on the focal plane and the depth of focus along the optical axis decrease, and the variation in chromaticity on the focal plane and along the axis increases rapidly. As the illuminance on the focal plane decreases the variation in chromaticity of optical system increases rapidly, and as the depth of focus increases the variation in chromaticity of optical system decreases.

  • PDF

Chromaticity (b*) and Transmittance of ITO Thin Films Deposited on PET Substrate by Using Roll-to-Roll Sputter System (롤투롤 스퍼터를 이용하여 PET 기판 위에 제조된 ITO 박막의 색도(b*) 및 투과도 연구)

  • Seo, Sung-Man;Kang, Bo-Gab;Kim, Hu-Sik;Lim, Woo-Taik;Choi, Sik-Young
    • Korean Journal of Materials Research
    • /
    • v.19 no.7
    • /
    • pp.376-381
    • /
    • 2009
  • Indium Tin Oxide (ITO) thin films on Polyethylene Terephtalate (PET) substrate were prepared by Roll-to-Roll sputter system with targets of 5 wt% and 10 wt% $SnO_2$ at room temperature. The influence of the chromaticity (b*) and transmittance properties of the ITO Films were investigated. The ITO thin films were deposited as a function of the DC power, rolling speed, and Ar/$O_2$ gas flow ratio, and then characterized by spectrophotometer. Their crystallinity and surface resistance were also analyzed by X-ray diffractometer and 4-point probe. As a result, the chromaticity (b*) and transmittance of the ITO films were broadly dependent on the thickness, which was controlled by the rolling speed. When the ITO films were prepared with the DC power of 300 W and the Ar/$O_2$ gas flow ratio of 30/1 sccm using 10 wt% $SnO_2$ target as a function of the rolling speeds 0.01 through 0.10 m/min, its chromaticity (b*) and transmittance were about -4.01 to 11.28 and 75.76 to 86.60%, respectively. In addition, when the ITO films were deposited with the DC power of 400W and the Ar/$O_2$ gas flow ratio of 30/2 sccm used in 5 wt% $SnO_2$ target, its chromaticity (b*) and transmittance were about -2.98 to 14.22 and 74.29 to 88.52%, respectively.

Chromaticity(b*), Sheet Resistance and Transmittance of SiO2-ITO Thin Films Deposited on PET Film by Using Roll-to-Roll Sputter System (롤투롤시스템을 이용하여 PET 필름위에 제조된 SiO2-ITO 박막의 색도(b*), 면저항과 투과도 연구)

  • Park, Mi-Young;Kang, Bo-Gab;Kim, Jung-Soo;Kim, Hye-Young;Kim, Hu-Sik;Lim, Woo-Taik;Choi, Sik-Young
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.255-262
    • /
    • 2011
  • This paper has relatively high technical standard and experimental skill. The fabrication of TCO film with high transparency, low resistance and low chromaticity require exact control of several competing factors. This paper has resolved these problems reasonably well, thus recommended for publication. Indium tin oxide(ITO) thin films were by D.C. magnetron roll-to-roll sputter system utilizing ITO and $SiO_2$ targets of ITO and $SiO_2$. In this experiment, the effect of D.C. power, winding speed, and oxygen flow rate on electrical and optical properties of ITO thin films were investigated from the view point of sheet resistance, transmittance, and chromaticity($b^*$). The deposition of $SiO_2$ was performed with RF power of 400W, Ar gas of 50 sccm and the deposition of ITO, DC power of 600W, Ar gas of 50 sccm, $O^2$ gas of 0.2 sccm, and winding speed of 0.56m/min. High quality ITO thin films without $SiO_2$ layer had chromaticity of 2.87, sheet resistivity of 400 ohm/square, and transmittance of 88% and $SiO_2$-doped ITO Thin film with chromaticity of 2.01, sheet resistivity of 709 ohm/square, and transmittance of more than 90% were obtained. As a result, $SiO_2$ was coated on PET before deposition of ITO, their chromaticity($b^*$) and transmittance were better than previous results of ITO films. These results show that coating of $SiO_2$ induced arising chromaticity($b^*$) and transmittance. If the thickness of $SiO_2$ is controlled, sheet resistance value of ITO film will be expected to be better for touch screen. A four point probe and spectrophotometer are used to investigate the properties of ITO thin films.

Application of Photocatalytic Degradation for Efficient Treatment of Organic Matter in Landfill Leachate in Jeju Island (제주도 매립장 침출수 중 유기물의 효율적 처리를 위한 광촉매 분해 반응의 응용)

  • Lee, Chang-Han;Lee, Taek-Kwan;Cho, Eun-Il;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.31 no.8
    • /
    • pp.677-689
    • /
    • 2022
  • In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3·6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3·6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.

Illumination Chromaticity Estimation in Single and Multiple Colored Image using Dichromatic Line Space (단일 및 다중 컬러 영상에서 이색성 선 공간을 이용한 조명 색도 추정)

  • Choi Yoo Jin;Yoon Kuk-Jin;Kweon In So
    • Journal of KIISE:Software and Applications
    • /
    • v.33 no.1
    • /
    • pp.84-94
    • /
    • 2006
  • The color information in an image changes as the illuminant condition varies. The mechanism to find canonical color of an object by estimating illumination color in an image is generally referred as color constancy. In color constancy, computing robust and precise dichromatic line is most important to estimate illumination chromaticity. In this paper, a novel approach to estimate the color of a single illuminant for noisy and micro-textured images is introduced. An accurate dichromatic line is found by using Dichromatic Line Space (DLS), proposed in this paper. which has information about diffuse chromaticity and illumination chromaticity.

Transformation of Illuminant Chromaticity for Arbitrary Color Temperature (임의 색온도에 대한 조명 색 변환기법)

  • Kim Jeong-Yeop;Kim Sang-Hyun;Hyun Ki-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.10
    • /
    • pp.1370-1377
    • /
    • 2004
  • The still image and video of the same scene taken under various condition show different color, and the most important factor of capture condition is scene illuminant. The average color of contents is determined along the color temperature of scene illuminant, the method for conversion of scene illuminant chromaticity is needed. In this paper, the method for converting the scene illuminant chromaticity from arbitrary correlated color temperature to another arbitrary one is proposed. Conventional method only defines several set of color temperature conversion that can be evaluated as representative ones. The proposed method has the merit of calculating the conversion function directly from arbitrary color temperature to another one.

  • PDF

Brightness and chromaticity characteristics of ZnGa$_{2}$O$_{4}$:Mn,O phosphors (ZnGa$_{2}$O$_{4}$:Mn,O 형광체의 휘도 및 색도 특성)

  • 박용구;한정인;곽민기;한종근;주성후
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.262-267
    • /
    • 1997
  • In order to improve the brightness and chromaticity of green emitting low voltage phosphor for FED, we examine PL, PLE and CL emission characteristics of ZnGa$_{2}$O$_{4}$:Mn,O prepared in Ar and vacuum. ZnGa$_{2}$O$_{4}$:Mn,O sintered in vacuum shows about 16 times as bright as the one fabricated in Ar and excellent chromaticity. In PL emission spectra of ZnGa$_{2}$O$_{4}$:Mn,O at low temperature of 9 K, two peaks are observed at 504 nm and 513 nm. At room temperature, the two peaks are superimposed due to the lattice thermal vibrational energy, and only one peak is observed at 509 nm. From PLE measurements, it is believed that the energy levels of the host lattice and Mn ions are coexisted. The energy transfer from the host lattice to the emission center of Mn$^{2+}$ ions occurs.s.

  • PDF