• 제목/요약/키워드: chlorine-hypochlorite solution

검색결과 23건 처리시간 0.029초

Influence of Acetylation on the Antimicrobial Properties of Chitosan Non-Woven Fabrics

  • Shin, Hye Kyoung;Park, Mira;Kim, Hak-Yong;Jin, Fan-Long;Choi, Heung Soap;Kim, Keziah H.;Kim, David S.;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2441-2445
    • /
    • 2013
  • Chitosan non-woven fabrics were acetylated to improve their antimicrobial properties. The active chlorine content, antimicrobial properties, storage stability, and surface properties of acetylated chitosan non-woven fabrics were investigated. The active chlorine content of the fabrics increased upon reduction of the degree of the acetylation or increase in sodium hypochlorite concentration. Acetylated chitosan non-woven fabrics showed powerful antimicrobial activity by efficiently killing Escherichia coli and forming a growth inhibition zone for Staphylococcus aureus. Furthermore, scanning electron microscopy observations demonstrated that the acetylated chitosan non-woven fabrics were not damaged in sodium hypochlorite solution.

샐러드의 미생물학적 위해 감소를 위한 세척 조건 확립 (Establishment of Washing Conditions for Salad to Reduce the Microbial Hazard)

  • 김정원;김수희
    • 한국식품조리과학회지
    • /
    • 제21권5호
    • /
    • pp.703-708
    • /
    • 2005
  • The purposes of this study were to establish washing conditions for vegetable salad to reduce the microbial hazard by using sodium hypochlorite solution and eventually to implement HACCP for salad processing. By using the salad production line of Shinkeum Co. located in Gwacheon, Gyunggi-do, salad samples were washed under several washing conditions (chlorine dip period, chlorine concentration, rinse time, etc.) to determine the most effective conditions. The original washing line consisted of 3 baths (100 ppm chlorine water dip, water rinse, and water rinse), each with a capacity of 100 L of tap water and 5 kg of salad. First, the salad samples were washed with 100 ppm of sodium hypochlorite solution for various dip times (3, 6, 9, 12 min); however, only a 1 log- or less-reduction in total microbial counts was achieved in all groups and the time of chlorine water dip was not a significant factor in reducing the microbial hazard. When another water bath was added before the chlorine water dip (4-bath washing), a 2 log-reduction in total microbial counts was achieved. This result suggested the importance of pre-dipping salad materials in water before chlorine treatment to reduce the organic load on the surface of the vegetables. Coliforms were not detected at all after washing. As the concentration of chlorine $(50{\sim}150\;ppm)$ and rinse time $(0.5{\sim}2\;min)$ increased, greater microbial reduction was achieved; however, physical damage of the salad was observed. Finally, the optimum washing conditions for salad were determined as 3 min-water dip, 3 min-chlorine (100 ppm) dip, 2 min-rinse, and 2 min-rinse.

전기분해 염소소독공정의 반응표면분석법을 이용한 차아염소산나트륨 발생 최적화 (Application of Response Surface Methodology to Optimize the Performance of the Electro-Chlorination Process)

  • 주재현;박찬규
    • 한국환경보건학회지
    • /
    • 제48권3호
    • /
    • pp.167-175
    • /
    • 2022
  • Background: Disinfection is essential to provide drinking water from a water source. The disinfection process mainly consists of the use of chlorine and ozone, but when chlorine is used as a disinfectant, the problem of disinfection by-products arises. In order to resolve the issue of disinfection by-products, electro-chlorination technology that produces chlorine-based disinfectants from salt water through electrochemical principles should be applied. Objectives: This study surveys the possibility of optimally producing active chlorine from synthetic NaCl solutions using an electro-chlorination system through RSM. Methods: Response surface methodology (RSM) has been used for modeling and optimizing a variety of water and wastewater treatment processes. This study surveys the possibility of optimally producing active chlorine from synthetic saline solutions using electrolysis through RSM. Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. Results: Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. A central composite design (CCD) was applied to determine the optimal experimental factors for chlorine production. Conclusions: The concentration of the synthetic NaCl solution and the distance between electrodes had the greatest influence on the generation of hypochlorite disinfectant. The closer the distance between the electrodes and the higher the concentration of the synthetic NaCl solution, the more hypochlorous acid disinfectant was produced.

담배추출물의 알카로이드감소에 미치는 산화제의 영향 (The Effect of Oxidizing Agents on Alkaloid Reduction of Tobacco Extract)

  • 황건중
    • 한국환경보건학회지
    • /
    • 제8권2호
    • /
    • pp.33-46
    • /
    • 1982
  • This experiment was carried out for the purpose of reducing alkaloid in reconstituted tobacco sheet and effluent of reconstituted tobacco sheet manufacturing company by treating oxidizing agents such as ozone, sodium hypochlorite, perchloric acid and hydrogen peroxide to tobacco extract created from the manufacturing process of reconstituted tobacco sheet. The effect of alkaloid reduction in tobacco extract by the volume added, time of treatment and pH of oxidizing agents were as follows: 1. When the solid rate of tobacco extract stood at 10 percent, the content of alkaloid, total sugar, total nitrogen and chlorine was 1,600mg/l, 11,000mg/l, 3,200mg/l and 4,000mg/l, respectively. 2. The effect of alkaloid reduction through ozone treatment was in proportion to time of ozone treatment. Alkaloid showed a 31.2 percent reduction under 8 hours' ozone treatment and 0.23g ozone consumed to remove lmg alkaloid. 3. Alkaloid reduction through sodium hypochlorite treatment was influenced by quantity of chlorine in sodium hypochlorite solution. To remove lmg alkaloid, 36.3mg chlorine was used. Reduction of alkaloid was not affected by time of sodium hypochlorite treatment, while showed the best reaction under pH 5-7. 4. The effect of alkaloid reduction by perchloric acid was under the control of the volume added and time of treatment of perchloric acid. The volume of perchloric acid required to remove alkaloid was on the decrease as time of treatment was getting longer. lmg alkaloid was removed by 0.15g perchloric acid under 8 hours' perchloric acid treatment. 5. Alkaloid reduction reacted slowly to the volume added and time of treatment of hydrogen peroxide. Under 8 hours' hydrogen peroxide treatment, it showed maximum removal, registering 10 percent alkaloid reduction.

  • PDF

닭고기에서 병원성 및 변질미생물의 감소를 위한 염소와 유산의 병용처리 효과 (Efficacy of chlorine and lactic acid for reducing pathogenic and spoilage microorganisms on chicken skin)

  • 이철현;변유성;황보원;강호조
    • 한국동물위생학회지
    • /
    • 제22권4호
    • /
    • pp.411-418
    • /
    • 1999
  • In this studies, the ability of chlorine and lactic acid to reduce bacterial population of the pathogenic microorganisms were examined on artificially inoculated chicken skin. About 10$^{5}$ cells of staphylococcus aureus, salmonella enteritidis, listeria monocytogenes and escherichia coli O157:H7 were inoculated in chicken skin. The contaminated samples were washed for 1 min with sodium hypochlorite solutions that contained 2, 5, 10, 20 and 50mg/$\ell$ available chlorine and counted number of the agents. Viable population were no significantly difference (p$\geq$0.05) between concentration of chlorine and strains of the pathogens. In the samples inoculated with pathogens were washed in 20mg/$\ell$ chlorine and then stored at $^5{\circ}C$ for up to 10 days, the initial counts of psychrotrophs and aerobic plate counts were 4.02 to 4.36 log cfu/$\textrm{cm}^2$ and increased slightly in course of time. But 10 days after, the pathogens were a little reduced from 3.66~4.91 log cfu/$\textrm{cm}^2$ to 2.54~4.66 log cfu/$\textrm{cm}^2$. In the case of washed skin with solution of 20mg/$\ell$ chlorine and 0.5% lactic acid then store at $^5{\circ}C$ for up to 10 days, population of psychrotrophs and aerobic plate counts on chicken skin were markedly reduced immediately after treatment, but the numbers of contaminants were slightly increased after 6 and 8 days. Specifically, numbers of St aureus, S enteritidis, L monocytogenes and E coli O157:H7 were reduced to 0.5, 0.4, 0.3 and 1.15 log cfu/$\textrm{cm}^2$ after 10 days of storage, respectively, on aerobic plate counts.

  • PDF

와이퍼 블레이드 고무의 표면 처리에 따른 특성 (The Characteristics of Wiper Blade Rubber with Surface Treatments)

  • 노승백;임미애;박진규;손전익
    • Elastomers and Composites
    • /
    • 제33권1호
    • /
    • pp.27-36
    • /
    • 1998
  • The surface of wiper blade(W/B) rubber was chlorinated by chemical treatment method using the hydrochloric acid(HCI) and sodium hypochlorite(NaOCl). From the results of contact angle measurement, friction coefficient measurement, and ATR-IR spectra, the surface characteristics of chlorinated W/B rubber with time of chlorination were studied. Contact angles for W/B rubber with increasing time of chlorination and chlorine concentration were measured for the water and ethylene glycol. From the results, contact angle fell rapidly with increasing time of chlorination and chlorine concentration, reaching a constant value after about 10min. And the wettability of W/B rubber surface by means of chlorination has been improved. For an unchlorinated W/B rubber, the friction coefficient with time of chlorination decreased from 1.27 to 0.20~0.23 on full chlorination. As the results it was considered that abrasion resistance of W/B rubber surface has been also improved. The values of pH and $Cl^-$ ion concentration in a chlorine treatment solution decreased as the extent of chlorination of W/B rubber surface increased. From the results of ATR-IR spectra, it was observed that C=C double band of W/B rubber surface transformed into C-Cl band, but quantitative determination of the extent of chlorination was not feasible because of the complexity of chlorination reactions.

  • PDF

Enhanced performance of thin-film nanocomposite RO/NWF membrane by adding ZnO nanospheres in aqueous phase during interfacial polymerization process

  • Li, Hongbin;Shi, Wenying;Su, Yuheng;Hou, Hongxiang;Du, Qiyun;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.225-244
    • /
    • 2017
  • A novel thin-film nanocomposite (TFN) reverse osmosis (RO)/non-woven fabric (NWF) membrane was prepared by adding zinc oxide (ZnO) nanospheres ($30{\pm}10nm$) during the interfacial polymerization process of m-phenylenediamine (MPD) and trimesoyl chloride (TMC) on self-made polysulfone (PSF) membrane/polyester (PET) non-woven fabric support. The improved performance of TFN RO membrane was verified in terms of water contact angle (WCA), water flux, salt rejection, antifouling properties and chlorine resistance. The results showed that the WCA value of TFN RO surface had a continuous decrease with the increasing of ZnO content in MPD aqueous solution. The water flux of composite TFN RO membranes acquired a remarkable increase with a stable high solute rejection (94.5 %) in $1g{\cdot}L^{-1}$ NaCl aqueous solution under the optimized addition amount of ZnO (1 wt%). The continuous testing of membrane separation performance after the immersion in sodium hypochlorite solution indicated that the introduction of ZnO nanospheres also dramatically enhanced the antifouling properties and the chlorine resistance of composite RO membranes.

찰옥수수 산화전분의 이화학적 특성 (Physicochemical Properties of Oxidized Waxy Maize Starches with Sodium Hypochlorite)

  • 정만곤;전영승;이서구;박종문;임번삼
    • 한국식품과학회지
    • /
    • 제30권1호
    • /
    • pp.42-48
    • /
    • 1998
  • 찰옥수수 전분을 차아염소산 나트륨$(0{\sim}60{\;}mg/s{\;}starch)$과 반응시켜 제조한 찰옥수수 산화전분의 이화학적 특성 및 유화 안정성에 미치는 영향에 대하여 연구하였다. 찰옥수수 산화전분의 일반성분 중 조지방질 및 조단백질 함량은 차아염소산 나트륨 처리량의 증가에 따라 감소하여 조단백질 함량과 백색도와 부의 상관관계$(R^2=0.9847)$를 나타내었고 조회분 함량은 증가하여 염소 함량과정의 상관관계$(R^2=0.9693)$를 나타내었다. 산화전분의 카르복시기 함량은 활성염소 첨가 농도에 비례하여 증가하였다. 호화액의 점도는 차아염소산 나트륨 처리량에 따라 현저히 감소하였고, 용해도와 팽윤력은 산화도가 높을 수록 증가하었으며, 광투과도는 치환도가 증가할 수록 낮은 온도에서 높은 투과도를 나타내어 화화개시온도가 약 $15^{\circ}C$낮아졌고, 호화액의 투명도 또한 개선되었다. 물결합능력은 치환도가 증가할 수록 생성된 카르복시기로 인하여 감소하였다. 찰옥수수 전분의 입자는 다각형과 원형의 혼합물로 크기는 $3.7{\sim}20\;{\mu}m$였으며, 차아염소산 나트륨 처리량이 증가할 수록 전분 표면이 거칠어졌다. 찰옥수수 산화전분과 옥배유를 균질화하여 저장하는 동안 유화액은 산화전분의 치환도가 높을 수록 전분의 농도가 증가할 수록 유화 안정성이 증가하였다.

  • PDF

전해수의 특성에 관한 연구 (The Study of Characteristics of Electrolytic Water)

  • 이찬우;배기서
    • 한국염색가공학회지
    • /
    • 제18권6호
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.