• 제목/요약/키워드: chlorine water disinfection

검색결과 151건 처리시간 0.02초

D 정수처리장에서 소독부산물 발생 및 종분포 특성 (The Characteristics of Disinfection by-products Occurrence and Speciation in D Water Treatment Processes)

  • 김성준;김종민;전용태;박종은;원찬희
    • 한국물환경학회지
    • /
    • 제26권3호
    • /
    • pp.406-412
    • /
    • 2010
  • Concentrations and speciations of Trihalomethanes (THMs) and Haloacetic acids ($HAA_5$) that can be formed during chlorine disinfection by-product (DBPs) in full-scale drinking water treatment plants were investigated. Jeon-ju D water treatment plant that adopted conventional water treatment processes was chosen for investigation. SUVA values according to water treatment process changes were observed from 1.3 to 2.1. The process average concentrations of THMs was 7.4 ppb, 9.0 ppb and 14.7 ppb respectively, while the average concentrations of $HAA_5$ by each process which are precipitation water, filterater water, treated water, were 15.5 ppb, 14.9 ppb and 25.8 ppb respectively. DBPs concentrations was lower in the winter than summer. The major species of THMs was chloroform and the second highest was bromodichloromethane (BDCM) and the third highest was dibromochloromethane (DBCM). In case of $HAA_5$, the rate of trichloroacetic acid (TCAA) was detected. The species disribution of THMs is related to the change of SUVA and species disribution of $HAA_5$ is related to the concentrations of bromine and injection position of chlorine and injection quantity.

음용 원수의 염소소독에 의한 소독부산물 생성패턴에 관한 연구 II (A Study on Formation Pattern of DBPs by Disinfection of Drinking Raw Water II)

  • 이강진;홍지은;표희수;박송자;유제강;이대운
    • 분석과학
    • /
    • 제17권1호
    • /
    • pp.69-81
    • /
    • 2004
  • 한강과 낙동강에서 채취한 원수에 염소소독제인 hypochlorite를 $10{\mu}g/mL$의 농도로 투여한 후 1시간 ~ 14일까지 TOC (total organic carbon), 잔류염소량 및 14종의 염소소독부산물 생성율을 조사하였다. 그 결과 TOC 및 탁도는 큰 차이가 없었으며 잔류염소량은 한강에서 투여 후 1시간 경과 시 $6{\mu}g/mL$ 이상에서 14일째에 $1.23{\mu}g/mL$으로 감소한 반면 낙동강의 경우 3일 이후 거의 존재하지 않았다. 7일 후 발생한 총 소독부산물의 농도는 한강의 경우 101.3 ng/mL (789.6 nM)이며 이 중 THMs (trihalomethanes)가 68%로 가장 큰 비중을 차지하였다. 그 외에 HAAs (haloacetic acids, 19%), chloral hydrate(10%)가 검출되었으며, 낙동강의 경우 총 소독부산물의 농도가 98.4 ng/mL (678.6 nM)이며 이 중 HAAs가 57%로 가장 큰 비중을 차지하였다. 그 외에 THMs (34%), HANs (haloacetonitriles, 5%) 및 chloropicrin등 질소화합물의 농도가 증가하였다. 이는 낙동강의 경우 한강에 비해 상대적으로 많이 포함된 암모니아성 질소가 소독제인 염소와 반응하여 클로라민을 생성함으로써 염소에 의한 소독효과와 클로라민에 의한 소독효과를 함께 나타내기 때문인 것으로 사료되며 전체적인 소독부산물들의 생성비율 경향을 살펴보면 소독제의 종류에 따라 소독부산물의 생성패턴에 차이가 있으나 산성도가 큰 HAAs의 초기 생성농도가 높고 점차 THMs의 생성속도가 증가하였다.

Post-Chlorination Process Control based on Flow Prediction by Time Series Neural Network in Water Treatment Plant

  • Lee, HoHyun;Shin, GangWook;Hong, SungTaek;Choi, JongWoong;Chun, MyungGeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권3호
    • /
    • pp.197-207
    • /
    • 2016
  • It is very important to maintain a constant chlorine concentration in the post chlorination process, which is the final step in the water treatment process (hereafter WTP) before servicing water to citizens. Even though a flow meter between the filtration basin and clear well must be installed for the post chlorination process, it is not easy to install owing to poor installation conditions. In such a case, a raw water flow meter has been used as an alternative and has led to dosage errors due to detention time. Therefore, the inlet flow to the clear well is estimated by a time series neural network for the plant without a measurement value, a new residual chlorine meter is installed in the inlet of the clear well to decrease the control period, and the proposed modeling and controller to analyze the chlorine concentration change in the well is a neuro fuzzy algorithm and cascade method. The proposed algorithm led to post chlorination and chlorination improvements of 1.75 times and 1.96 times respectively when it was applied to an operating WTP. As a result, a hygienically safer drinking water is supplied with preemptive response for the time delay and inherent characteristics of the disinfection process.

전기분해수 처리에 의한 딸기의 살균 효과 및 저장 중 품질변화 (Disinfection Effects of Electrolyzed Water on Strawberry and Quality Changes during Storage)

  • 정진웅;김종훈;권기현;박기재
    • 한국식품저장유통학회지
    • /
    • 제13권3호
    • /
    • pp.316-321
    • /
    • 2006
  • 전해 방식에 따라 제조된 전기분해수로 세정처리한 딸기의 살균효과 및 저장중 품질변화를 살펴본 결과, 전기분해수에 의한 딸기의 미생물학적 살균효과는 침지수량은 중량 대비 10배수, 침지시간은 20분 처리시 초기균수에 대하여 2 log cycle 정도 감소하며 저장중 균증식 속도도 다소 느리게 나타났다. 폐기율은 $5^{\circ}C$ 저장시 EW-2 처리구에서 저장 5일째까지 10%수준을 보여 무처리 및 염소수 처리에 비해 낮은 폐기율을 보여주었고, 조직감도 $5^{\circ}C$ 저장 전기분해수 처리구에서는 저장 3일까지는 조직감 변화가 거의 없다가 그 이후 오히려 증가하는 경향을 나타내었다. 딸기의 표면색도 변화는 저장기간이 경과할 수록 무처리구와 CW 처리구는 전반적으로 L값이 증가하는 경향을 보인 반면에 전기분해수 처리구는 감소하는 경향을 보여 주었고, 저장기간별 색차(${\Delta}E$)값은 저장 3일까지는 무처리구가 가장 적은 변화를 나타내었다. 전기분해수 처리에 의한 초기 잔류염소량은 $0.04{\sim}0.06ppm$수준이며 저장 1-3일 경과 후에는 모든 처리구에서 $0.02{\sim}0.03ppm$ 수준으로 잔류염소량이 거의 동일하게 나타났다. 저장중 관능적 특성은 전기분해수 처리구(EW-1 및 EW-2)가 무처리 및 CW 처리구에 비해 높게 나타났다.

녹조류(Chlamydomonas pulsatilla)에 의한 염소소독부산물 생성과 그 특성 (Characterization of Disinfection By-Products by Chlamydomonas pulsatilla)

  • 금희정;김준성;정용
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.535-540
    • /
    • 2005
  • This study was conducted to evaluate the chlorinated disinfection by-products formation potential (DBPFP) produced from the cell and extracellular product (ECP) of Chlamydomonas pulsatilla after chlorination. Reaction yields of DBPs produced by C. pulsatilla of ECP and the cell were $0.007{\mu}mol/mg{\cdot}C$ and $0.808{\mu}mol/mg{\cdot}C$ respectively, Also, SUVA values of ECP and the cell were measured as $0.313L/mg{\cdot}m$ and $1.052L/mg{\cdot}m$ respectively, The DOC of cell was found to be lower than that of ECP, while the SUVA value and reaction yields for the cell were higher than those of ECP. For ECP, most of the DBPFP was composed of trihalomethanes (THM; 47.3%) and haloacetonitriles (HAN; 38,83%). THM and HAN were the major DBPFP produced by the cell. Chloroform was found to be the major THM compound; 98.3% for ECP and 99.98% for the cell. Dichloroacetic acid (DCAA) and dichloroacetonitrile (DCAN) were identified as the major haloacetic acid (HAA) and HAN compounds formed by ECP and the cell as a precursor, respectively. As the chlorine dose was increased, concentrations of DOC, THMs, and HANs were increased. However, the chlorine dose decreased the concentration of chlorophyll-a.

Ecotoxicological effects of ballast water effluent teated by an electrolytic method on marine environment

  • Kim, Tae Won;Kim, Keun-Yong;Shon, Myung-Baek;Kim, Young-Soo;Lee, Ji Hyun;Moon, Chang Ho;Son, Min Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.1010-1020
    • /
    • 2014
  • Ballast water effluent treated by an electrolytic method contains reactive chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on marine environment. WET testing was carried out for three marine pelagic organisms, i.e., diatom Skeletonema costatum, rotifer Brachionus plicatilis and fish Paralichthys olivaceus. The biological toxicity test revealed that S. costatum was the only organism that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50% (EC50) values of 12.5%, 25.0% and 83.3%, respectively, at brackish water condition. In contrast, it showed insignificant toxicity at seawater condition. B. plicatilis and P. olivaceus also showed no toxicities to the effluent at the both salinity conditions. Meanwhile, chemical analysis revealed that the ballast water effluent contained total residual oxidants (TROs) below $0.03{\mu}g/L$ and a total of 20 DBPs including bromate, volatile halogenated organic compounds (VOCs), halogenated acetonitriles (HANs), halogenated acetic acids (HAAs) and chloropicrin. Based on ERA, the 20 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. Except monobromoacetic acid, the ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the other 19 DBPs did not exceed 1. Thus, our results of WET testing and ERA indicated that the ballast water effluent treated by electrolysis and subsequently neutralization was considered to have no adverse impacts on marine environment.

수돗물의 앙금발생규명 및 저감기술방안 (Study on the alternatives to trace the origin and to diminish the sediments of drinking water)

  • 김갑수;임병진;권은미
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.17-28
    • /
    • 1994
  • There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.

  • PDF

정수처리공정에서 NOM 거동과 소독부산물 발생특성 (Characterization of NOM Behavior and DBPs Formation in Water Treatment Processes)

  • 김상은;구윤희;유명진;장현성;이수원;한선희
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.395-407
    • /
    • 2007
  • Disinfection by-products(DBPs) are formed through the reaction between chlorine and natural organic matter(NOM) in water treatment. For reducing the formation of chlorinated DBPs in the drinking water treatment, there is a need to evaluate the behavior of NOM fractions and the occurrence of DBPs for each fraction. Among the six fractions of NOM, the removal of HPOA and HPIN got accomplished through coagulation and sedimentation processes. Advanced water treatment processes were found to be most significant to remove the HPOA and HPON. It was found that HPOA made the most THMFP level than any other fractions and HPIA and HPOA formed higher HAAFP. The fraction of NOM with MW less than 1k Da was 32.5~54.3% in intake raw water. Mostly the organic matter with MW more than 1k Da was removed through coagulation and sedimentation in the drinking water treatment processes. In case of advanced water treatment processes, the organic matter with MW 1k~100k Da decreased by means of ozone oxidation for high molecular weight substances. As the result low molecular organic matter increased. In the BAC and GAC processes, the organic matter with MW less than 100k Da decreased.

THMs, HAAs의 종분포 (Speciation of THMs, HAAs)

  • 김진근
    • 대한환경공학회지
    • /
    • 제28권11호
    • /
    • pp.1135-1140
    • /
    • 2006
  • 국내 정수장에서 염소소독시 발생하는 소독부산물인 트리할로메탄(THMs), 할로아세틱에시드(HAAs)의 발생농도와 각각의 종별 분포현황을 조사하였다. 조사대상은 일반적인 정수처리공정으로 구성된 한강, 금강, 섬진강, 낙동강 수계의 1개 정수장씩 총 4개소였다. THMs의 발생농도는 평균 26.9 ppb, 최대 46.7 ppb, 최소 11.0 ppb였으며, $HAA_5$의 발생농도는 평균 25.4 ppb, 최대 57.1 ppb, 최소 9.7 ppb였다. 계절적으로는 동절기에 농도가 낮았고 하절기에 높았다. THMs의 종별 분포를 조사한 결과 클로로포름의 비율이 평균 77%로 가장 높았고 다음으로는 브로모디클로로메탄(20%)이 높게 검출되었으며, 브로모포름의 농도는 정량한계 미만이었다. $HAA_5$의 경우 디클로로아세틱에시드(DCAA)와 트리클로로아세틱에시드(TCAA)의 합이 $HAA_5$의 97%를 차지하는 것으로 조사되었다. 그러나 한강수계의 경우는 이 비율이 평균 90%로 다소 낮았으며, 특히 겨울철에 비율이 가장 낮았다. 한편, 하절기를 제외하고는 DCAA가 TCAA보다 높은 것으로 조사되었다.

음용수 소독 미량 유기오염물질 생성에 대한 생물활성탄(Biological Activated Carbon)의 흡착제거 특성 (The Adsorption Removal Characteristics of Trace Organic By-Products in Disinfection of Drinking Water by Biological Activated Carbon(BAC))

  • 옥치상;김정아;배기철
    • 한국환경과학회지
    • /
    • 제1권1호
    • /
    • pp.53-68
    • /
    • 1992
  • In order to research the adsorption removal characteristics of trace organic by-products in disinfection of drinking water by biological activated carbon(BAC), water samples disinfect- ted with $Cl_2$, $O_3$ and $ClO_2$ after treatment by fluidized-bed system with water added with humic acid(10mg/L) were investigated the formation and the removal of trihalomethanes (THMs), and the trace organic by-products by gas chromatography(GC) II gas chromatography/mass selective detector(GC/MSD). Control was used by activated carbon(AC) and water added with humic acid(HA). The results were summarized as follow : The THMs removal effect of BAC by chlorination was in lower 90 % than that of control(HA), the sorts of oxidants formed by $Cl_2$ , $O_3$ and $ClO_2$ were that $O_3$ was very fewer than $Cl_2$ or $ClO_2$, and that $ClO_2$ was fewer than $Cl_2$. The trace organic by-products were esters and phthalates etc. Based on results above, it is concluded that BAC was appeared the more desirable adsorbtion-degradation removal characteristics than that of AC.

  • PDF