• Title/Summary/Keyword: chlorine ion

Search Result 160, Processing Time 0.027 seconds

Chlorine effect on ion migration for PCBs under temperature-humidity bias test (고온고습 전원인가 시험에서 Cl에 의한 이온 마이그레이션 불량)

  • Huh, Seok-Hwan;Shin, An-Seob
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.47-53
    • /
    • 2015
  • By the trends of electronic package to be more integrative, the fine Cu trace pitch of organic PCB is required to be a robust design. In this study, the short circuit failure mechanism of PCB with a Cl element under the Temperature humidity bias test ($85^{\circ}C$/85%RH/3.5V) was examined by micro-structural study. A focused ion beam (FIB) and an electron probe micro analysis (EPMA) were used to polish the cross sections to reveal details of the microstructure of the failure mode. It is found that $CuCl_x$ were formed and grown on Cu trace during the $170^{\circ}C$/3hrs and that $CuCl_x$ was decomposed into Cu dendrite and $Cl_2$ gas during the $85^{\circ}C$/85%RH/3.5V. It is suggested that Cu dendrites formed on Cu trace lead to a short circuit failure between a pair of Cu traces.

Kinetic Studies of Chlorine Exchange between Benzyl Chloride and Radioactive Chloride Ion (Benzyl Chloride의 Chlorine 交換反應)

  • Park, Yong-Ja;Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 1965
  • Halogen exchanges between benzyl chloride and chloride ion have been studied in 90% ethanol-water mixture, and activation parameters in the exchange reaction have been determined; ${\Delta}H^{\neq}$ = 18. 50 Kcal and ${\Delta}S^{\neq}$ = -22. 09 e. u. Results indicated that the reaction proceeded via a typical bimolecular mechanism. The importance of nucleophilic ability of attacking anion in $S_N2$ process has been stressed giving some experimental evidence. The order of reactivity of halides in the exchange reaction is better explained with the Swain's nucleophilic parameter than with the bond dissociation energies.

  • PDF

Development of Catalytic Characteristics for Enhancement of Iso-Butene Yield in Isomerization of 1-butene (1-butene의 골격 이성질화 반응에 있어서의 Iso-butene 수율 제고를 위한 촉매 특성 개발)

  • Kim, Jin Gul
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.191-196
    • /
    • 1997
  • The isothermal reduction on $Pt/MoO_3/SiO_2$ at $50^{\circ}C$ demonstrates that the rate of hydrogen spillover is increased as calciantion temperature increases. That is due to the overlayer formation over the surface of Pt crystallites, investigated by TEM and CO chemisorption. It is known that reaction mechanism of skeletal isomerization of 1-butene into iso-butene is composed of 2 step such as formation of carbonium ion and isomerization of methyl group. It is expected that the increase of i-butene yield after calcination at $250^{\circ}C$ is due to increased rate of hydrogen spillover coming from first, overlayer formation over Pt surface and second, chlorine lessoning from $PtCl_x$ precursor.

  • PDF

Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique (CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석)

  • Jeong, Jongsik;Lee, Seungjae;Lee, Jaebok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

Diagnostics of Inductively Coupled $BCl_3/Ar$ Plasma Characteristics Using Quadrupole Mass Spectrometer (사중극자 질량 분석기를 이용한 $BCl_3/Ar$ 유도결합 플라즈마 특성 진단)

  • Kim, Gwan-Ha;Kim, Chang-Il
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.204-208
    • /
    • 2006
  • In this study, we investigated the ion energy distributions in a chlorine based inductively coupled plasma by quadrupole mass spectrometer with an electrostatic ion energy analyzer. Ion energy distributions are presented for various plasma parameters such as $BCl_3/Ar$ gas mixing ratio, RF power, and process pressure. As the $BCl_3/Ar$ gas mixing ratio and process pressure decreases, and RF power increases, the saddle-shaped structures is enhanced. The reason is that there are ionized energy difference between $BCl_3$ and Ar, change of plasma potential, alteration of mean free path. and variety of ion collision in the sheath.

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

Formation Mechanism of Chlorate ($ClO_3\;^-$) by Electrochemical Process (전기화학적 공정에 의한 클로레이트의 생성메커니즘)

  • Baek, Ko-Woon;Jung, Yeon-Jung;Kang, Joon-Wun;Oh, Byung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.627-634
    • /
    • 2009
  • This study was done to find out the formation mechanism of chlorate by electrochemical process using chloride ion ($Cl^-$) as an electrolyte. Firstly, the effective factors such as pH and initial chloride concentration were figured out to see the formation property of chlorate during electrolysis. And the relation of free chlorine, and mixed oxidants such as OH radical and ozone with chlorate were estimated to concretize the formation mechanism. As a result, it was found that the major reaction of chlorate formation would be electrochemical reaction with free chlorine, and also the direct oxidation of chloride ion and the reaction by OH radical were participated in the formation of chlorate. Moreover, it was observed that formed chlorate was oxidized to perchlorate. Lastly, the optimum condition was recommended by comparing free chlorine with chlorate concentration during the electrochemical process with the different electrode separation.

A Study on the NOx Reduction of Flue Gas Using Seawater Electrolysis (해수 전기분해를 적용한 배연 탈질 기술에 관한 연구)

  • Kim, Tae-Woo;Kim, Jong-Hwa;Song, Ju-Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.570-576
    • /
    • 2012
  • In this study, we investigated the characteristics of NO oxidation using un-divided electrolyzed seawater as oxidant. The concentration of available chlorine and the temperature of electrolyzed seawater are increased with electrolysis time in the closed-loop constant current electrolysis system. While NO gas flow through bubbling reactor which is filled with electrolyzed seawater, the oxidation rate of NO to $NO_2$ is increased with the concentration of available chlorine and the temperature. $NO_2$, generated by oxidation reaction, is dissolved in electrolyzed seawater and existed as $HNO_3{^-}$ ion.

Effect of Power Intensity on the Phenol and Chlorinated Compounds Mixture Solutions by Ultrasound (초음파로 페놀 분해 시 염소계화합물의 첨가와 음향 강도의 영향)

  • Lim, Myunghee;Son, Younggyu;Yang, Jaekeun;Khim, Jeehyeong
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.118-122
    • /
    • 2008
  • Degradations of phenol and chlorinated compounds mixtures were studied with ultrasound of 20 kHz and 0.57, 1.14 W/mL. In presence of carbon tetrachloride (CT), degradation rate of phenol is faster than chloroform (CF), dichloromethane (DCM) and phenol solution. It is due to that CT generates of free chlorine (HOCl and $OCl^-$) from the sonochemical degradation and plays a role of hydrogen atom scavenger. CF and DCM are react with free chlorine, so amount of free chlorine is smaller than CT solution. The degradation rates of chlorinated compounds decreased with co-presence of phenol in the solution due to the distribution ultrasonic energy to both compounds. The measured chloride ion was lower than the theoretical concentration assuming complete degradation. This means not all the contaminants destructed went through complete degradation.

The Characteristics of Wiper Blade Rubber with Surface Treatments (와이퍼 블레이드 고무의 표면 처리에 따른 특성)

  • Rho, Seung-Baik;Lim, Mi-Ae;Park, Jin-Kyu;Son, Jeon-Ik
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.27-36
    • /
    • 1998
  • The surface of wiper blade(W/B) rubber was chlorinated by chemical treatment method using the hydrochloric acid(HCI) and sodium hypochlorite(NaOCl). From the results of contact angle measurement, friction coefficient measurement, and ATR-IR spectra, the surface characteristics of chlorinated W/B rubber with time of chlorination were studied. Contact angles for W/B rubber with increasing time of chlorination and chlorine concentration were measured for the water and ethylene glycol. From the results, contact angle fell rapidly with increasing time of chlorination and chlorine concentration, reaching a constant value after about 10min. And the wettability of W/B rubber surface by means of chlorination has been improved. For an unchlorinated W/B rubber, the friction coefficient with time of chlorination decreased from 1.27 to 0.20~0.23 on full chlorination. As the results it was considered that abrasion resistance of W/B rubber surface has been also improved. The values of pH and $Cl^-$ ion concentration in a chlorine treatment solution decreased as the extent of chlorination of W/B rubber surface increased. From the results of ATR-IR spectra, it was observed that C=C double band of W/B rubber surface transformed into C-Cl band, but quantitative determination of the extent of chlorination was not feasible because of the complexity of chlorination reactions.

  • PDF