• Title/Summary/Keyword: chlorine ($Cl_2$

Search Result 357, Processing Time 0.025 seconds

An Experimental Study on Corrosion Behavior in Steel of Concrete Applied with Arc Metal Spray Method Surface Treatment Technology Using EIS (EIS를 이용한 아크 금속용사 표면처리기법이 적용된 강재의 콘크리트 내 부식 거동에 관한 실험적 연구)

  • Yoon, Chang-Bok;Park, Jang hyun;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.87-95
    • /
    • 2020
  • As an experimental study on the corrosion behavior of steel materials to which ATMS method using EIS was applied in concrete, immersion of Ca(OH)2 saturated aqueous solution and NaCl aqueous solution simulating the environment inside concrete The corrosion behavior was tested. The equivalent circuit was derived through the analysis of the Nyquist plot, and the interfacial resistance and the polarization resistance of the Ca(OH)2 aqueous solution were compared, and Al ATMS was the best interfacial resistance and Zn ATMS was the best polarization resistance. After burying ATMS steel material of cement mortar, the initial immersion impedance measurement value was the highest in the Zn ATMS test body in the impedance measurement by the immersion time by immersing it in the NaCl aqueous solution. Al ATMS test piece has the highest impedance and is highly reliable. This is because Al, which has a high ionization tendency, is continuously oxidized in a strong alkaline environment to form a film and protect the steel from permeation of chlorine ions.

Investigation on the Cause of Malodor through the Reproduction of Chemicals (화학물질의 재현을 통한 악취발생원인 규명)

  • Park, Sang Jun;Oh, Young Hwan;Jo, Bo Yeon;Lee, Jae Shin;Kim, Eui Yong
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.392-398
    • /
    • 2014
  • It was confirmed that malodor connected with an air-conditioner in an automobile is caused by microbial volatile organic compounds (MVOCs) produced by microorganisms and through microorganisms coexisting with each other to form a biofilm on the evaporator surface. A bacterium, Methylobacterium aquaticum, can form a biofilm on the evaporator surface. The biofilm was composed of 45.79% C (Carbon), 42.36% O (Oxygen), 1.85% Na (Sodium), 5.42% Al (Aluminum), 1.39% P (Phosphorus), 0.74% Cl (Chlorine) and 2.45% K (Potassium). This result matches the composition of the biofilm formed on the surface of the used evaporator. It was determined that sulfur compounds (Hydrogen sulfide, Dimethyl sulfide) and organic acids (n-Butyric acid, n-Valeric acid, iso-Valeric acid) in the air which was blown into the automobile were generated by Methylobacterium aquaticum and Aspergillus versicolor, respectively. On the other hand, volatile organic compounds (Toluene, Xylene, 2-Ethylhexanol, 2-Phenyl- 2-propanol, Ethylbenzene) were not found. It is estimated that the reason is due to the low concentration of generated MVOCs or is caused by the change of some MVOCs depending on the nutrients (medium).

Orientation and Defects of $SnO_2$ Films Deposited by Spray Pyrolysis (무열분해법으로 증착한 $SnO_2$ 박막의 방향성과 결함구조)

  • Kim, Tae-Heui;Park, Kyung-Bong
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.137-144
    • /
    • 1998
  • Tin oxide films deposited by spray pyrolysis have defects and preferred orientations according to the temperature of substrate. The growth of crystalline deposits began at the substrate temperature of $300^{\circ}C$. With increasing substrate temperature the plane (200) groved preferentially and above $400^{\circ}C$, planes of higher indices. Grain size increased with increasing substrate temperature up to $400^{\circ}C$. Undoped film is composed of Sn and O, and contains oxygen vacancies. Film doped with antimony has defects such as oxygen vacancies, antimony substituted on Sn and chlorine on oxygen.

  • PDF

Identification of the Failure of VFD Heat Sink at Fossil Power Plant

  • Jung, Jine-sung;Lee, Han-sang;Kim, Min-tae;Kim, Eui-hyun
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.153-156
    • /
    • 2009
  • The water cooling system for VFD (Variable Frequency Drive) of a fossil fuel power plant was reported to be shut down due to a water leak at the metal connection of the heat-sink to the hoses. In order to identify the cause of the failure, the system was visually inspected, and corrosion products were analyzed with SEM equipped with EDX. The failure was observed repeatedly at the nipples of certain location, suggesting galvanic corrosion. In a U-shaped heat sink with two nipples, for inlet and outlet, only one nipple was corrosively damaged at the tip, while the other was not. Most of the corrosion products were observed at the sound nipple and in the filter, identified as $Cu(OH)_2$. Some other corrosion products, composed of mostly $Cu_2O$, were found at the corrosively attacked nipple. A fair amount of Cl was also detected on the surface of the damaged nipple. It was concluded that galvanic corrosion was occurred due to a current leakage over the whole system, and the damage was accelerated by the accumulated chlorine ions in the cooling water.

Corrosion Properties of Duplex Stainless Steels - STS329LD and STS329J3L - for the Seawater Systems in Nuclear Power Plant

  • Chang, Hyun-Young;Park, Heung-Bae;Kim, Young-Sik;Ahn, Sang-Kon;Jang, Yoon-Young
    • Corrosion Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Lean duplex stainless steels have been developed in Korea for the purpose of being used in the seawater systems of industry. There are also many important seawater systems in nuclear power plants. These systems supply seawater to cooling water condenser tubes, heat exchanger tubes, related pipes and chlorine injection systems. The flow velocity of some part of seawater systems in nuclear power plants is high and damages of components from corrosion are severe. The considered lean duplex stainless steels are STS329LD (20.3Cr-2.2Ni-1.4Mo) and STS329J3L (22.4Cr-5.7Ni-3Mo) and PRENs of them are 29.4 and 37.3 respectively. Physical, mechanical and micro-structural properties of them are evaluated, and electrochemical corrosion resistance is measured quantitatively in NaCl solution. Critical Pitting Temperatures (CPT)s are measured on these alloys and pit depths are evaluated using laser microscope. Long period field tests on these alloys are now being performed, and some results are going to be presented in the following study.

The Crystal and Molecular Structure of Theophylline Hydrochloride (Theophylline 鹽酸鹽의 結晶 및 分子構造)

  • Chung Hoe Koo;Hyun So Shin;Sun Suk Oh
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.86-94
    • /
    • 1978
  • The crystal and molecular structure of theophylline hydrochloride has been determined from X-ray data by Patterson techniques. The structure has been refined by block-diagonal least-squares and Fourier synthesis on three dimensional data. The unit cell is orthorhombic, space group $P_{na21}$, with a = 14.01, b = 11.49, c = 6.77${\AA}$, and contains four molecules. The final R value based on 743 observed reflexions is 12.2%. The intramolecular distances are similar to those in other compounds containing a purine or pyrimidine group. The molecules are nearly planar and are stacked in layers parallel to the (001)plane. The chlorine atom is coordinated to N(1) atom at a distance of 3.06${\AA}$. The structure is stabilized mainly by van der Waals interactions; however, a short N${\cdot}{\cdot}{\cdot}$Cl contact of length $3.06\AA$, which is slightly less than the expected van der Waals separation, suggest that weak charge transfer interaction may be present. The relationship between this structure and the known structures of theophylline monohydrate and caffeine monohydrate are discussed.

  • PDF

Regeneration of PCB Etchants and Copper Recovery in a Batch-type Electrolytic Cell (회분식 전해조에서 PCB 식각폐수의 재생 및 구리의 회수)

  • Nam, Sang Cheol;Nam, Chong Woo;Tak, Yongsug;Oh, Seung Mo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.161-171
    • /
    • 1997
  • Anodic regeneration of PCB enchant and cathodic deposition of copper using electrochemical method has been studied. Cu(I)/Cu(II) concentration ratio as a function of Cu(I) oxidation at the anode was measured from the potential difference between platinum and Ag/AgCl/4M KCl electrodes. Chlorine gas evolution was minimized by maintaining Cu(I) concentration above a specific concentration and using non-porous graphite electrode. Dendritic copper deposition was observed at the cathode and the optimum conditions for Cu deposition was identified as the current density of $360mA/cm^2$, and copper concentration of 12 g/l. Titanium was the most effective cathode material which showed a higher current efficiency and copper recovery. The current efficiency decreased with increasing temperature, but the highest power efficiency was achieved at $50^{\circ}C$.

  • PDF

A study on the needs to improve Korea abattoir's critical control point of HACCP system

  • Kim, Seongjoon;Choi, Kwanghoon;Myung, Donghoon;Chung, Hangsung;Kim, Sukwon;Choe, Nonghoon
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.105-108
    • /
    • 2020
  • These days abattoirs' hygiene of Korea is regulated by Hazzard Analysis Critical Control Point (HACCP). Although 20 years have been left since first HACCP was adjusted in Korea, 12% of abattoirs got inconsistence on evaluations. Food poisoning caused by bacteria feces like pathogenic Escherichia coli and Salmonella has not decreased. These bacteria on meat cross-contaminate at the abattoir. Therefore, field verification of abattoir's critical control point (CCP) and experiments to find alternative ways of the CCP were conducted. The aerobic bacteria were measured before and after high-pressure water based washing process set as CCP in most abattoirs. Four parts of cattle carcasses were selected to apply sponge-swab method. The effects were < 1 log reduction which is not significant. Lactic acid (LC), chlorine dioxide (ClO2) and slightly acidic electrolyzed water (SAEW) were used to measure the effect of reducing bacteria on beef by the different time. LC has 1.24-2.02 log reduction for aerobic bacteria. ClO2 has 1.44-1.96 log reduction for aerobic bacteria. SAEW has 1.1-1.91 log reduction for aerobic bacteria. There was significant difference according to concentrations (p < 0.05). This study presents legitimacy for hygiene improvement of CCP by field verification. In addition, chemical disinfectants that can be mechanically applied have better reduction effects of high-pressure washing.

Effects of Deposition Parameters on TiN Film by Plasma Assisted Chemical Vapor Deposition(I) -Influence of Temperature on the TiN Deposition- (플라즈마 화학 증착법(PACVD)에 의한 TiN 증착시 증착변수가 미치는 영향(I) -증착온도를 중심으로-)

  • Shin, Y.S.;Ha, S.H.;Kim, M.I.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.4
    • /
    • pp.1-10
    • /
    • 1989
  • To investigate the influence of temperature on the TiN film, it was deposited on the STC-3 steel and Si-wafer from $TiCl_4/N_2/H_2$ gas mixture by using the radio frequency plasma assisted chemical vapor deposition. The deposition was performed at temperature of $400^{\circ}C-500^{\circ}C$. The results showed that crystalline TiN film was deposited over $480^{\circ}C$, and all specimens showed the crystalline TiN X-ray diffraction peaks after vacuum heat treatment for 3 hrs, at $1000^{\circ}C$, $10^{-5}torr$. While the film thickness was increased above $480^{\circ}C$, it was decreased under $480^{\circ}C$ as temperature increased. And the contents of titanium were increased and it of chlorine were decreased as temperature increased. Because temperature increase was attributed to the increase in the density of TiN film, surface hardness of TiN film was increased with temperature.

  • PDF

Effect of Combined Treatment of Ultraviolet-C with Aqueous Chlorine Dioxide or Fumaric Acid on the Postharvest Quality of Strawberry Fruit "Flamengo" during Storage ("플라멩고" 딸기의 수확 후 Ultraviolet-C와 이산화염소수 또는 푸마르산 병합 처리에 따른 저장 중 품질에 미치는 영향)

  • Kim, Ju-Yeon;Kim, Hyun-Jin;Lim, Geum-Ok;Jang, Sung-Ae;Song, Kyung-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.1
    • /
    • pp.138-145
    • /
    • 2010
  • The combined effect of 50 ppm aqueous chlorine dioxide ($ClO_2$) or 0.5% fumaric acid with $5 kJ/m^2$ ultraviolet-C (UV-C) on the postharvest quality of "Flamengo" strawberries was examined. After non-thermal treatment, the samples were stored at $4\pm1^{\circ}C$ for 12 days. The combined treatment of fumaric acid/UV-C reduced the initial populations of total aerobic bacteria and yeast and molds in the strawberries by 2.09 and 2.02 log CFU/g, respectively, compared to those of the control. In addition, after 12 days of storage the yeast and molds population in the combined treatment was 1.72 log CFU/g, compared to 5.10 log CFU/g for the control, resulting in a significant decrease of 3.38 log CFU/g. Postharvest treatments used in this study caused negligible changes in the color of the strawberries. Sensory evaluation results indicated that the combined postharvest treatment provided better sensory scores than did the control. In particular, the overall acceptability scores were higher for the combined treatment groups after 5 days of storage. These results suggest that combined treatment of either 50 ppm $ClO_2$ or 0.5% fumaric acid with $5 kJ/m^2$ UV-C can be useful for maintaining the quality of strawberries.