• 제목/요약/키워드: chloride treatment

검색결과 1,086건 처리시간 0.028초

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • 제13권5호
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.

Influence of counter anions on metal separation and water transport in electrodialysis treating plating wastewater

  • Oh, Eunjoo;Kim, Joohyeong;Ryu, Jun Hee;Min, Kyung Jin;Shin, Hyun-Gon;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.201-206
    • /
    • 2020
  • Electrodialysis (ED) is used in wastewater treatment, during the processing and recovery of beneficial materials, to produce usable water. In this study, sulfate and chlorine ions, which are the anions majorly used for electroplating, were studied as factors affecting the recovery of copper, nickel and water from wastewater by electrodialysis. Although the removal rates of copper and nickel ions were slightly higher with the use of chlorine ions than of sulfate ions, the removal efficiencies were above 99.9% under all experimental conditions. The metal ions of the plating wastewater flowed through the ion exchange membrane of the diluate tank and the concentrate tank while all the water moved together due to electro-osmosis. The migration of water from the diluate tank to the concentrate tank was higher in the presence of a monovalent chloride ion compared to that of a divalent sulfate ion. When sulfate was the anion used, the recoveries of copper and nickel increased by about 25% and 30%, respectively, as compared to the chloride ion. Therefore, when divalent ions such as sulfate are present in the electrodialysis, it is possible to reduce the movement amount of water and highly concentrate the copper and nickel in the plating wastewater.

Study of chemical coagulation conditions for a disperse red dye removal from aqueous solutions

  • Tiaiba, Mohammed;Merzouk, Belkacem;Mazour, Mohammed;Leclerc, Jean P.;Lapicque, Francois
    • Membrane and Water Treatment
    • /
    • 제9권1호
    • /
    • pp.9-15
    • /
    • 2018
  • Coagulation process using aluminum sulfate ($Al_2(SO_4)_3$) and ferric chloride ($FeCl_3$) was employed as a treatment method for decolorization of a synthetic textile wastewater containing red dye in this paper. Factors such as initial pH, coagulant dosage, initial concentration, conductivity and mixing conditions that influence color removal efficiency were experimentally tested. It was found that $Al_2(SO_4)_3$ is more efficient than $FeCl_3$ as coagulant. When $40mgL^{-1}$ aluminum sulfate was used, results showed that color induced by the red dye was efficiently removed (> 90 %) and was obtained in a large range of initial pH from 4 to 8 with, and for a dye concentration lower than $235mg\;L^{-1}$. After addition of the coagulant, the medium had to be mixed for 30 min at 60 rpm, then allowed to settle for 40 min. The effects of water conductivity in the range $0.035-2.42mS\;cm^{-1}$ and dye concentration up to $380mg\;L^{-1}$ were also followed and discussed.

Pore Structure Characterization of Poly(vinylidene chloride)-Derived Nanoporous Carbons

  • Jung, Hwan Jung;Kim, Yong-Jung;Lee, Dae Ho;Han, Jong Hun;Yang, Kap Seung;Yang, Cheol-Min
    • Carbon letters
    • /
    • 제13권4호
    • /
    • pp.236-242
    • /
    • 2012
  • Poly(vinylidene chloride) (PVDC)-derived nanoporous carbons were prepared by various activation methods: heat-treatment under an inert atmosphere, steam activation, and potassium hydroxide (KOH) activation at 873, 1073, and 1273 K. The pore structures of PVDC-derived nanoporous carbons were characterized by the $N_2$ adsorption technique at 77 K. Heat treatment in an inert atmosphere increased the specific surface area and micropore volume with elevating temperature, while the average micropore width near 0.65 nm was not significantly changed, reflecting the characteristic pore structure of ultramicroporous carbon. Steam activation for PVDC at 873 and 1073 K also yielded ultramicroporosity. On the other hand, the steam activated sample at 1273 K had a wider average micropore width of 1.48 nm, correlating with a supermicropore. The KOH activation increased the micropore volume with elevating temperature, which is accompanied by enlargement of the average micropore width from 0.67 to 1.12 nm. The average pore widths of KOH-activated samples were strongly governed by the activation temperature. We expect that these approaches can be utilized to simply control the porosity of PVDC-derived nanoporous carbons.

Cyclized Induction of Phenylalanine Ammonia-Lyase Gene Expression in Rhizoctonia solani-Infected Stems of Tomato

  • Yeo, Yun-Soo;Kim, Soo-Jin;Koo, Bon-Sung;Lee, Churl-Ho;Lee, Shin-Woo
    • Journal of Plant Biotechnology
    • /
    • 제6권3호
    • /
    • pp.151-156
    • /
    • 2004
  • Soil-borne fungal pathogens such as Verticillium and Rhizoctonia can colonize in the stem tissue of plant through root and lead to wilting symptoms of plant by blocking. water transportation. During the colonization of Rhizoctonia solani in the vascular tissue of tomato stems, particularly, phenylalanine ammonia-lyase (PAL) gene induction pattern was cyclized showing peak induction at two different time points (10 and 80 h) after fungal spores inoculation in vivo. In leaves or roots, however, no such cycling pattern was observed. The first induction peak may be due to an initial sporulation events leading to a second induction peak by a proliferation of fungal spores to the upper stems or other tissues from an initial spore trapping sites. Tomato PAL gene was also dramatically induced by wounding, light illumination and mercury chloride treatment but was not cyclized. Mercury chloride showed the earliest induction with all tissues even at half an hour after treatment.

건축재로 국산목질과 포틀랜드 시멘트 (Korean Lignocellulosics and Portland Cement as a Structural Material)

  • 안원영;알리 에이 모슬레미
    • Journal of the Korean Wood Science and Technology
    • /
    • 제12권4호
    • /
    • pp.36-46
    • /
    • 1984
  • 한국식목질과 포틀랜드 시멘트(Type I)로 건축재개발가능성을 구명하기 위하여 소나무, 리기다 소나무, 잣나무, 일본잎갈나무, 현사시나무 목질과 왕겨 및 볏짚과 포틀랜드 시멘트 그리고 물과 혼합하여 24시간동알 수화열을 측정하고 수화억제지수를 산출한 바 리기다 소나무와 소나무가 한정된 조건하에서 목질-시멘트 복합체에 적절한 수종이며, 열수추출 수행하면 경화억제지수가 개선되어 왕겨, 잣나무, 일본잎갈나무는 한정된 조건하에서 적절한 수종이고 열수추출과 경화촉진제와 염화칼슘이나 염화마그네슘을 경울하면 현사시나무 일본 잎 갈나무도 리기다 소나무와 아울러 우수한 수종으로 판명되었다.

  • PDF

Corrosion Behavior and Oxide Film Formation of T91 Steel under Different Water Chemistry Operation Conditions

  • Zhang, D.Q.;Shi, C.;Li, J.;Gao, L.X.;Lee, K.Y.
    • Corrosion Science and Technology
    • /
    • 제16권1호
    • /
    • pp.8-14
    • /
    • 2017
  • The corrosion behavior of a ferritic/martensitic steel T91 exposed to an aqueous solution containing chloride and sulfate ions is investigated depending on the stimulated all-volatile treatment (AVT) and under oxygenated treatment (OT) conditions. The corrosion of T91 steel under OT condition is severe, while the corrosion under AVT condition is not. The co-existence of chloride and sulfate ions has antagonistic effect on the corrosion of T91 steel in both AVT and OT conditions. Unlike to corrosion resistance in the aqueous solution, OT pretreatment provides T91 steel lower oxidation-resistance than VAT pretreatment. From scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) and X-ray diffraction (XRD) analysis, the lower corrosion resistance in the aqueous solution by VAT conditions possibly is due to the formation of pits. In addition, the lower oxidation resistance of T91 steel pretreated by OT conditions is explained as follows: the cracks formed during the immersion under OT conditions accelerated peeling-off rate of the oxide film.

화학적 침전공정에 의한 염색가공폐수의 처리 (Treatment of Dye-Processing Wastewater by Chemical Precipitation)

  • Han, Myung-Ho;Huh, Man-Woo;Kim, Jeong-Mog;Lee, Jin-Sik;Lim, Hak-Sang
    • 한국염색가공학회지
    • /
    • 제9권6호
    • /
    • pp.26-32
    • /
    • 1997
  • In order to remove the pollutants effectively in the dye-processing wastewater by chemical precipitation, coagulation and flocculation test was carried out using several coagulants on various reaction conditions. It was found that the Ferric sulfate was best coagulant for the treatment of mixed dye-processing wastewater. When the Ferric sulfate dosage was 1,100mg/$\ell$, the COD removal rate was very high(50%), and the color was removed very effectively. The COD was decreased relatively well up to 40%, when Alum was dosed as coagulant. But it was difficult to remove the color effectively. Test results about COD removal for the Ferrous sulfate and the Ferric chloride used were mostly same as those of the Alum used. However, the color removal by the Ferrous sulfate was much better than the case of the Alum or the Ferric chloride. It was found that the COD removal was increased and the sludge yield was decreased by pH control before polymer flocculant addition, during the jar test for the Ferrous sulfate and the Ferric sulfate as a coagulant.

  • PDF

기수지역 선박평형수의 염소 생성 효율에 미치는 전기화학 처리의 영향 (Effect of Electrochemical Treatment on the Chlorine Generation Efficiency of Ballast Water in the Brackish Zone)

  • 최용선;이유기
    • 한국재료학회지
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2019
  • Indirect oxidation using chlorine species oxidizing agents is often effective in wastewater treatment using an electrochemical oxidation process. When chlorine ions are contained in the wastewater, oxidizing agents of various chlorine species are produced during electrolysis. In a ballast water management system, it is also used to treat ballast water by electrolyzing seawater to produce a chlorine species oxidizer. However, ballast water in the brackish zone and some wastewater has a low chlorine ion concentration. Therefore, it is necessary to study the chlorine generation current efficiency at various chlorine concentration conditions. In this study, the chlorine generating current efficiency of a boron-doped diamond(BDD) electrode and insoluble electrodes are compared with various chloride ion concentrations. The results of this study show that the current efficiency of the BDD electrode is better than that of the insoluble electrodes. The chlorine generation current efficiency is better in the order of BDD, MMO(mixed metal oxide), $Ti/RuO_2$, and $Ti/IrO_2$ electrodes. In particular, when the concentration of sodium chloride is 10 g/L or less, the current efficiency of the BDD electrode is excellent.

정수 슬러지로부터 알루미늄 응집제의 회수에 관한 연구 (Recovery of Aluminium Coagulants from Water Treatment Plant Sludges)

  • 이재복;황정욱;김진재
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.30-40
    • /
    • 1998
  • Increasing water consumption produced sludge problems of the water treatment plants. The objective of this study is to investigate aluminium coagulants recovery n acidic and alkaline conditions. Water treatment plant sludge produced in Pusan Metropolitan City were tested for the aluminium extraction process. Experiment samples were obtained in summer from water treatment plants of Deoksan and Myongjang. Aluminium coagulants used in these plants during the test period were polyaluminium chloride(PAC), polyaluminium sulfate organic(PSO), polyaluminium sulfate silicate(PASS). Aluminium contents of water treatment sludge were in the range of 7.2~10.9% of the total solids. The recovery percentages for aluminium and iron by acidic extraction method was evaluated to 88% and 42% respectively. Extracted mass variation for other materials such as iron, manganese, total organic carbon was observed during the extraction operation. Alkaline extraction produced more than two times amount of total organic carbon than that in the acidic extraction process.

  • PDF