• 제목/요약/키워드: chiral HPLC

검색결과 86건 처리시간 0.034초

Chromatographic chiral resolution of several racemic drugs containing primary amino moiety on a chiral stationary phase

  • Lee, Won-Jae;Baek, Chae-Sun;Jin, Jing-Yu
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.278.3-279
    • /
    • 2003
  • A chiral stationary phase (CSP) prepared by bonding (18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA) to aminopropyl silica gel by HPLC was used in resolving several racemic drugs containing primary amino moiety. Most compounds used in this study were resolved on the CSP using 80% methanol in water (V/V) containing 10mM sulfuric acid as a mobile phase. These results on the CSP were compared to those on the similar CSP derived from 18-C-6-TA of the same chiral selector by different connecting method.

  • PDF

Enantioseparation of Neutral Compounds on a Quinine Carbamate-Immobilized Zirconia in Reversed-Phase Capillary Electrochromatography

  • Lee, Mun-Rak;Gwon, Ju-Rim;Park, Jung-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권1호
    • /
    • pp.82-86
    • /
    • 2010
  • Quinine (QN) is a weak anion-exchange type chiral selector and QN-based silica stationary phases have been widely used for enantioseparation of acidic chiral analytes in HPLC and recently in CEC. In this work we report enantioseparation of non-acidic chiral analytes on a quinine carbamate-immobilized zirconia (QNZ) in reversed-phase (RP) CEC. Influences of pH, composition of the buffer, acetonitrile content and the applied voltage on enantioseparation were examined. Enantiomers of the analytes investigated are well separated in acetonitrile/phosphate buffer mobile phases. Separation data on QNZ were compared to those on QN-bonded silica (QNS). Retention was longer but better enantioselectivity and resolution were obtained on QNZ than QNS.

Chiral Separation of $\beta$-Blockers after Derivatization with (-)-Menthyl chloroformate by Reversed-Phase High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Choi, Pok-Wha;Hong, Seon-Pyo;Kim, Hyun-Ju
    • Archives of Pharmacal Research
    • /
    • 제22권6호
    • /
    • pp.608-613
    • /
    • 1999
  • Optimum conditions of chiral derivatization reaction of $\beta$-blockers (acebutolol, arotinolol, betaxolol, bisoprolol, celiprolol, metoprolol and pindolol) with (-)-menthyl chloroformate were investigated for the resolution by HPLC. With more than 30 times molar excess of (-)-methyl chloroformate chiral derivatization reactions were completed within one hour at room temperature except arotinolol and celiprolol. Diastereomeric derivatives of $\beta$-blockers were well resolved on the ODS column using acetonitrile-methanol-water as a mobile phase.

  • PDF

Propatation and Application of a New HPLC Chiral Stationary Phase Edrived from 2-Amino-1-indanolo

  • 현명호;장영수;민혜정;김도훈;엄봉호
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.401-404
    • /
    • 2001
  • A new chiral stationary phase (CSP) based on (1R,2S)-2-amino-1-indanol, which is expected to be conformationally rigid because of its cyclic nature, was prepared. The new CSP was applied in resolving various $N-acyl-\alpha-arylalkylamines$. The chromatographic resolution results on the new CSP were compared with those on the other CSP based on (1S,2R)-norephedrine, which is believed to be conformationally flexible. Comparison of the chromatographic resolution results on the two CSPs demonstrated that conformationally flexible analytes are resolved better on the conformationally rigid CSP while conformationally rigid analytes are resolved better on the conformationally flexible CSP. From these results it was concluded that conformational rigidity or flexibility of CSPs is the important factor for the chiral recognition.

Enantioseparation on HPLC Chiral Stationary Phases

  • Hyun Myung-Ho;Ryoo Jae-Jeong;Min Chung-Sik;William H. Pirkle
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권4호
    • /
    • pp.407-413
    • /
    • 1992
  • The chromatographic separation of the stereoisomers of the N-(3,5-dinitrobenzoyl) derivatives of fifteen dipeptide methyl esters and nine dipeptide alkyl esters was investigated on three different chiral stationary phases derived from N-acylated ${\alpha}-arylalkylamines$. Two of these CSPs contain second stereogenic centers. These secondary stereogenic centers of CSPs were proposed to provide secondary effects in terms of chiral recognition. From the elution orders of the four dipeptide stereoisomers and the separation factors of the enantiomeric pairs of the N-(3,5-dinitrobenzoyl) derivatives of the dipeptide alkyl esters having different alkoxy substituents, it was proposed that the intercalation of the alkoxy substituents of dipeptide derivatives between the connecting arm of CSPs may control the magnitude of chiral separations of dipeptide derivatives.

Determination of Enantiomeric Purity of (S)-(+)-Ibuprofen by $^1$H-NMR using (-)- Cinchonidine as a Chiral Solvating Agent

  • Lee, Jae-Yong;Seo, Sang-Hun;Kang, Jong-Seong;Kim, Kyeong-Ho
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.219.1-219.1
    • /
    • 2003
  • $^1$H-NMR method for the determination of enantiomeric purity of (S)-(+)-ibuprofen was developed using (-)-cinchonidine as a chiral solvating agent. (S)-(+)-ibuprofen was prepared by optical resolution of racemic ibuprofen using preferential recrystallization method with (S)-(-)-${\alpha}$-methylbenzylamine and (R)-(-)-ibuprofen by semi-preparative chiral HPLC using chiral OD column and n-hexane/2-propanol/trifluoroacetic acid as a mobile phase. Several concentrations of synthetic mixture of (S)-(+)-ibuprofen and (R)-(-)-ibuprofen were added to the (-)-cinchonidine disolved in CDCl$_3$. (omitted)

  • PDF

Enantioseparation by Sonochromatography

  • Ryoo, Jae-Jeong;Song, Young-Ae;Jeong, Young Han;Hyun, Myung-Ho;Park, Jung-Hag;Lee, Won-jae
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권5호
    • /
    • pp.637-641
    • /
    • 2006
  • Although chiral separation has been one of the main topics of chromatographic practice for over twenty-five years, it still presents many difficulties. In this work, the ultrasonic dependence of chiral resolution was investigated at various temperatures to improve resolution and reduce analysis time. The chiral resolution was performed on recently commercialized two HPLC chiral stationary phases (CSP 1 and CSP 2) with the analogues of racemic N-acylnaphthylethylamines (1a-d) and racemic amino acid derivatives (2a-c, 3a-c) as analytes. The CSP 1 was prepared from a (R)-N-(3,5-dinitrobenzoyl)phenylglycinol and the CSP 2 was prepared from a (S)-N-3,5-(dinitrobenzoyl) leucine. From the comparison of the chromatographic results under sonic condition with those under non-sonic condition, we found that the ultrasound decreased the elution time in chiral chromatography at all temperatures and improved the enantioselectivity at high temperature (45, 50, 60 ${^{\circ}C}$).

키랄 컬럼을 사용한 아미노산 에스테르의 니트로벤조옥사디아졸 유도체의 광학분리 (Enantiomer Separation of α-Amino Acid Esters as Nitrobenzoxadiazole Derivatives Using Chiral Columns)

  • 윤원남;김지연;이원재
    • KSBB Journal
    • /
    • 제28권6호
    • /
    • pp.423-427
    • /
    • 2013
  • A new convenient derivatization method of ${\alpha}$-amino acid esters as nitrobenzoxadiazole (NBD) derivatives for chiral resolution was introduced and the enantiomer separation of ${\alpha}$-amino acid esters as NBD derivatives was performed by normal HPLC using chiral columns based on polysaccharide derivatives. The NBD derivatives were readily prepared by stirring NBD-Cl and ${\alpha}$-amino acid methyl ester HCl with $NaHCO_3$ in ethanol. The performance of Chiralpak IA was superior to the other chiral stationary phases for enantiomer resolution of NBD derivatives of several ${\alpha}$-amino acid methyl esters. Owing to fluorescence detection as well as strong UV absorption, it is expected that the convenient analytical method developed in this study will be very useful for enantiomer separation of ${\alpha}$-amino acid esters as NBD derivatives on polysaccharide-derived chiral columns.

Liquid Chromatographic Reaolution of N-Protected α -Amino Acids as Their Anilide and 3,5-Dimethylanilide Derivatives on Chiral Syationary Phases Derived fron (S)-Leucine

  • Hyun, Myung-Ho;Cho, Yoon-Jae;Baik, In-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권9호
    • /
    • pp.1291-1294
    • /
    • 2002
  • Various racemic N-protected ${\alpha}-amino$ acids such as N-t-BOC-(tert-butoxycarbonyl), N-CBZ-(benzyloxycarbonyl) and N-FMOC-(9-fluorenylmethyloxycarbonyl) ${\alpha}-amino$ acids were resolved as their anilide and 3,5-dimethylanilde derivatives on an HPLC chira l stationary phase (CSP) developed by modifying a commercial (S)-leucine CSP. The chromatographic resolution results were compared to those on the commercial (S)-leucine CSP. The resolutions were greater on the modified CSP than those on the commercial CSP with only one exception, the resolution of N-t-BOC-phenylglycine anilide. In addition, the chromatographic resolution behaviors were quite consistent except for the resolution of N-protected phenylglycine derivatives, the (S)-enantiomers being retained longer. Based on the chromatographic resolution behaviors and with the aid of CPK molecular model studies, we proposed a chiral recognition mechanism for the resolution of N-protected ${\alpha}-amino$ acid derivatives. However, for the resolution of N-protected phenylglycine derivatives, a second chiral recognition mechanism, which competes in the opposite sense with the first chiral recognition mechanism, was proposed. The two competing chiral recognition mechanisms were successfully used in the rationalization of the chromatographic behaviors for the resolution of N-protected phenylglycine derivatives.