• Title/Summary/Keyword: chipping

Search Result 180, Processing Time 0.027 seconds

Development of Polycrystalline Diamond Tungsten Carbide Combination Circular Saw and Comparison of Tool Wear (PCD 초경 복합 원형 톱 개발과 공구마모 비교)

  • Joo, Chang-Min;Park, Yoon-Ok;Kim, Su-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.48-56
    • /
    • 2021
  • Tungsten carbide (WC) circular saws have been widely used to cut plywood. Recently, expensive polycrystalline diamond (PCD) were adopted to extend the tool life of circular saws. This study developed a PCD-WC combination circular saw and compared its performance with that of existing WC and PCD saws. Flank wear of WC saw blades and edge chipping of rectangular PCD was observed during the experiments. The PCD-WC saw replaced half of the chamfered teeth with PCD and applied tough WC for all rectangular teeth. In the experiments, edge chipping was not observed in rectangular WC teeth and the flank wear of chamfered teeth was decreased compared with that of conventional circular saws.

A Numerical Study on the Rock Fragmentation by TBM Cutter Penetration (TBM 커터 관입에 의한 암석 파쇄의 수치해석적 연구)

  • 백승한;문현구
    • Tunnel and Underground Space
    • /
    • v.13 no.6
    • /
    • pp.444-454
    • /
    • 2003
  • Rock fragmentation technique by cutter penetration has widely been used in the mechanical tunnel excavation. Microcracks propagate and interact because of locally concentrated high stress induced by cutter penetration. which is caused by heterogeneity of rocks. In this study Weibull distribution function and degradation index are used to consider the strength heterogeneity of a rock and the degradation of rock properties after failure. Through the numerical analyses, it is shown that the lateral pressure has an important influence on the rock fragmentation. In the single cutter penetration, large chips are formed as lateral pressure increase. The cutter spacing is also an important factor that affects the rock fragmentation in the double cutter penetration. The fragmentation efficiency of the double cutter penetration is better when cutter spacing is 70 mm than 40 mm and 100 mm. From the results, it is expected that this study can be applied to a TBM tunnel design by understanding of chipping process and mechanism of rock due to cutter penetration.

Adaptability and yield of Korean chipping potato varieties (Solanum tuberosum L.) in vietnam conditions

  • Luu, Thi thuy;Im, Seon yeong;Jeon, Young ji;Cho, Ji hong;Lee, Dong Jin
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.309-309
    • /
    • 2017
  • The experiments were carried out in open experimental field of Field Crops Research Institute, Hai Duong, Vietnam in Winter Spring seasons 2015-2016 and 2016-2017 for finding high yielding of Korean chipping potato varieties which are adaptable to Vietnam condition. Six varieties of Korean potato (G1, G2, G4, G10, B1, B2) were experimented. The control variety (G6) was Atlantic which has long been a standard chip variety. The results showed that, for a hill, there was positive correlation between number of stems and number of tubers. The hill yield also showed highly relation to the plant height and number of tubers. Even though the growth and yield of potatoes grown in the season 2016-2017 were significant higher than these of potatoes grown in the season 2015-2016, their percentages of tubers infected by scab disease were much higher. This is probably because of irregular soil moisture content at the tuber forming duration. While G1, G6 and B1 are white flesh varieties, the remaining are yellow flesh varieties. There are two shapes types among experimented varieties: oblong (G1, G10, B1) and round shape (G2, G4, G6, B2). The total yields of varieties G1, G2, B1, B2 were higher than the total yield of the control variety from 16.5-49.4% in the season 2015-2016 and from 39.8-75.6% in the season 2016-2017.

  • PDF

Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

  • Carrabba, Michele;Vichi, Alessandro;Louca, Chris;Ferrari, Marco
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.257-264
    • /
    • 2017
  • PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.

Assessing Dust and Crystalline Silica Exposures among Workers in Some Quarries in Korea (국내 일부 채석장 작업자들의 분진 및 결정형 유리규산 노출평가 사례)

  • Won-Seok Cha;Eun-Young Kim;Sung-Won Choi;Mi-Yeon Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.284-290
    • /
    • 2023
  • Objectives: Work environment assessments were conducted to investigate epidemiologically several cases of lung cancer and COPD (chronic obstructive pulmonary disease) among workers in domestic quarries. Methods: We visited three quarries in South Korea where an epidemiological investigation was requested and measured total dust, respirable dust, and crystalline silica on rock drilling workers (4 people) and rock chipping workers (13 people). Measurement and analysis were conducted according to NIOSH (National Institute for Occupational Safety & Health) method 0500, NIOSH method 0600 for respirable dust, and NIOSH method 7500 for crystalline silica. Results: Among rock drilling workers the AMs (arithmetic mean) of total dust concentrations, respirable dust concentrations, and crystalline silica concentrations were 3.462 mg/m3 (range: 0.764~6.085 mg/m3), 0.613 mg/m3 (range: 0.153~1.251 mg/m3), and 0.105 mg/m3 (range: 0.012~0.228 mg/m3), respectively. Among rock chipping workers, the AMs of total dust concentrations, respirable dust concentrations, and crystalline silica concentrations were 2.446 mg/m3 (range: 0.156~8.494 mg/m3), 0.488 mg/m3 (range: 0.028~1.536 mg/m3), and 0.099 mg/m3 (range: 0.004~0.274 mg/m3), respectively. Conclusions: Although it cannot be said that the dust concentrations were high for both rock drilling workers and rock chipping workers, the concentrations of crystalline silica were found to be high. If such work is performed for a long period of time, diseases such as lung cancer and COPD may occur, so the work environment needs to be improved.

Esthetic Full Zirconia Fixed Detachable Implant-Retained Restorations Manufactured from Monolithic Zirconia : Clinical Report (Monolithic zirconia framework으로 제작된 fixed detachable prostheses를 이용한 심미적인 임플란트 전악 수복 증례)

  • Hong, Jun-Tae;Choi, Yu-Sung;Han, Se-Jin;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.253-268
    • /
    • 2012
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption, since this includes the gingival area and restricts the position of the implants. however, hard- and soft-tissue grafting may allow the implants to be placed into the desired position. Although it is possible to regenerate lost tissues, an alternative is to use fixed detachable prostheses that restore the function and the esthetics of the gingiva and teeth. Various material combinations including metal/acrylic, metal/ceramic, and zirconia/ceramic have been used for constructing this type of restoration. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. With virtually unbreakable, chip-proof, life-like nature, monolithic zirconia frameworks can prospectively replace other framework materials. This clinical report describes the restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with dental implants. The occluding surfaces were made of monolithic zirconia, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.