Kim, Deok-Jong;Kim, Jae-Yun;Park, Sang-Jin;Heo, Pil-U;Yun, Ui-Su
연구논문집
/
s.33
/
pp.17-25
/
2003
In this work, thermal design of a PCR chip for LOC is systematically conducted. From the numerical simulation of a PCR chip based on the finite volume method, how to control the average temperature of a PCR chip and the temperature difference between the denaturation zone and the annealing zone is presented. The average temperature is shown to be controlled by adjusting heat input and a cooler as well as a heater is shown to be necessary to obtain three individual temperature zones for polymerase chain reaction. To reduce the time required, a heat sink for the cooler is not included in the calculation domain for the PCR chip and heat sink design is conducted separately by using a compact modeling method, the porous medium approach.
PCR-chip-based ultra-rapid multiplex PCRs for detection of six major infectious pathogens in honeybee were developed. The 6 kinds of major infectious pathogens in honeybee included Paenibacillus larvae causing American Foulbrood, Melissococcus plutonius causing European Foulbrood as bacteria, Ascosphaera apis (Chalkbrood), Aspergillus flavus (Stonebrood), Nosema apis and Nosema ceranae (Nosemosis) as fungi. The developed PCR-chip-based ultra-rapid multiplex PCR showed successful amplification for all six major pathogens in the presence of more than $10^3$ molecules. The time for confirming amplification (Threshold cycles; Ct-time) was about 7 minutes for two species, and about 9 minutes for four species. Total 40 cycles of PCR took 11 minutes 42 seconds and time for melting point analysis was 1 minute 15 seconds. Total time for whole PCR detection was estimated 12 minutes 57 seconds (40 cycles of PCR and melting point analysis). PCR-chip based ultra-rapid multiplex PCR using standard DNA substrates showed close to 100% accuracy and no false-amplification was found with honeybee genomic DNA. Ultra-rapid multiplex PCR is expected to be a fast and efficient pathogen detection method not only in the laboratory but also in the apiary field.
Transactions of the Korean Society of Mechanical Engineers A
/
v.32
no.4
/
pp.371-377
/
2008
Our precedent study has reported glass-PDMS (polydimethylsiloxane) based biochip for the gene PCR (polymerase chain reaction). To prevent the contamination of bio sample, the once used biochip must not be used repeatedly. However, the fabrication cost of microheater and microsensor of the biochip was not cheap to use it as a disposable chip. This paper proposes new PCR-chip where the glass substrate integrated with the microheater and microsensor is detachable from the reaction chamber where the sample is injected. That makes it possible to reuse the glass substrate repeatedly. The performance of the proposed detachable PCR-chip was compared with that of the precedent monolithic PCR-chip. The results showed that the SRY (sex determining Y chromosome) gene PCR was successfully performed in the detachable chip compared with the monolithic chip. However, the more efforts to improve the efficiency of surface treatment of PDMS chip are needed to increase the possibility of applying the detachable chip to the detecting of male infertility.
A rapid PCR-based assay for detecting hepatitis B viral DNA(HBV DNA) in serum and plasma was developed using a new PCR instrument named GenSpector(TMC-1000, Samsung electronics). PCR was carried out using a chip-based platform, which enabled 50 PCR cycles with internal controls, and melting-curve analysis in 30 minutes. Verification of the amplified HBV DNA product and the internal control was based on specific melting temperatures(Tm) analysis, executed by the GenSpector software. Primers were designed within the region conserved through HBV genotypes A to F. The lower limit of detection was 840 copies/ml serum, conducted with serial dilutions of a HBV DNA positive control(ACCURUN 325 series 700, Boston Biomedica Inc.). The assay was also compared to another assay for HBV DNA(Versant HBV DNA 3.0 assay, Bayer HealthCare) for 200 samples(each 100 clinical negative and positive samples). The sensitivity and specificity were 100% matched. This rapid PCR-based assay is specific, reproducible, and enables qualitative detection of HBV DNA.
Kim, Jeeyong;Lim, Da Hye;Mihn, Do-CiC;Nam, Jeonghun;Jang, Woong Sik;Lim, Chae Seung
Parasites, Hosts and Diseases
/
v.59
no.1
/
pp.77-82
/
2021
As malaria remains a major health problem worldwide, various diagnostic tests have been developed, including microscopy-based and rapid diagnostic tests. LabChip real-time PCR (LRP) is a small and portable device used to diagnose malaria using lab-on-a-chip technology. This study aimed to evaluate the diagnostic performance of LRP for detecting malaria parasites. Two hundred thirteen patients and 150 healthy individuals were enrolled from May 2009 to October 2015. A diagnostic detectability of LRP for malaria parasites was compared to that of conventional RT-PCR. Sensitivity of LRP for Plasmodium vivax, P. falciparum, P. malariae, and P. ovale was 95.5%, 96.0%, 100%, and 100%, respectively. Specificity of LRP for P. vivax, P. falciparum, P. malariae, and P. ovale was 100%, 99.3%, 100%, and 100%, respectively. Cohen's Kappa coefficients between LRP and CFX96 for detecting P. vivax, P. falciparum, P. malariae, and P. ovale were 0.96, 0.98, 1.00, and 1.00, respectively. Significant difference was not observed between the results of LRP and conventional RT-PCR and microscopic examination. A time required to amplify DNAs using LRP and conventional RT-PCR was 27 min and 86 min, respectively. LRP amplified DNAs 2 times more fast than conventional RT-PCR due to the faster heat transfer. Therefore, LRP could be employed as a useful tool for detecting malaria parasites in clinical laboratories.
Cho Chul-Ho;Cho Woong;Hwang Seung-Yong;Ahn Yoo-Min
Transactions of the Korean Society of Mechanical Engineers A
/
v.30
no.10
s.253
/
pp.1261-1268
/
2006
This paper reports low-cost microreactor $(10{\mu}{\ell})$ biochip for the DNA PCR (polymerase chain reaction). The microbiochip $(20mm{\times}28mm)$ is a hybrid type which is composed of PDMS (polydimethylsiloxane) layer with serpentine micochannel $(360{\mu}m{\times}100{\mu}m)$ chamber and glass substrate integrated with microheater and thermal microsensor. Undesirable bubble is usually created during sample loading to PMDS-based microchip because of hydrophobic chip surface. Created bubbles interrupt stable biochemical reaction. We designed improved microreactor chamber using microfluidic simulation. The designed reactor has a coner-rounded serpentine channel architecture, which enables stable injection into hydrophobic surface using micropipette only. Reactor temperature needed to PCR reaction is controlled within ${\pm}0.5^{\circ}C$ by PID controller of LabVIEW software. It is experimentally confirmed that SRY gene PCR by the fabricated microreactor chip is performed for less than 54 min.
Kim, Jung-Min;Lim, Su-Jin;Kim, SoMin;Kim, MoonJung;Kim, ByoungHee;Tai, Truong A;Kim, Seonmi;Yoon, ByoungSu
Journal of Veterinary Science
/
v.21
no.1
/
pp.4.1-4.9
/
2020
Fast and accurate detection of viral RNA pathogens is important in apiculture. A polymerase chain reaction (PCR)-based detection method has been developed, which is simple, specific, and sensitive. In this study, we rapidly (in 1 min) synthesized cDNA from the RNA of deformed wing virus (DWV)-infected bees (Apis mellifera), and then, within 10 min, amplified the target cDNA by ultra-rapid qPCR. The PCR products were hybridized to a DNA-chip for confirmation of target gene specificity. The results of this study suggest that our method might be a useful tool for detecting DWV, as well as for the diagnosis of RNA virus-mediated diseases on-site.
Kim, Seok Hwan;Lee, Yu-Si;Joo, In-Sun;Kwak, Hyo Sun;Chung, Gyung Tae;Kim, Soon Han
Journal of Food Hygiene and Safety
/
v.33
no.1
/
pp.50-57
/
2018
Salmonella continue to be a major cause of food poisoning worldwide. The rapid detection method of food-borne Salmonella is an important food safety tool. A real-time polymerase chain reaction (PCR) has been used as a rapid method for the detection of pathogens. It has been recently reported that NBS LabChip real-time PCR is a novel, ultrafast, and chip-type-convenient real-time PCR system. We developed the assay method based on NBS LabChip real-time PCR for the rapid detection of Salmonella, which its reaction time was within 20 minutes. Two target genes (invA and stn) were selected to design target specific primers and probes. The new method was validated by checking specificity and sensitivity (limit of detection). This study included forty-two target and twenty-one non-target strains to assess the specificity. This assay was able to identify the 42 Salmonella strains correctly. The limit of detection (LOD) was $10^1copies/{\mu}L$ in Salmonella genomes DNA, while LOD incubated for 4 hr in the inoculated sausage sample ranged from $10^1CFU/g$ to $10^2CFU/g$ as an inoculated cell count. The assay developed in this study could be applied for the investigation of food poisoning pathogens.
An oligonucleotide microarray system was developed for the simultaneous detection of porcine epidemic diarrhea virus, transmissible gastroenteritis virus, porcine enteric calicivirus, porcine group A and C rotavirus. RNAs of the reference viruses and porcine diarrhea samples were extracted and amplified using one-step multiplex RT-PCR in the presence of cyanine 5-dCTP and hybridized on the microarray chip that spotted the virus-specific oligonucleotides. This system were approximately 10-to 100-fold higher in sensitivity than conventional RT-PCR, and the assay time was less than 3 hours. The relative sensitivity and specificity were 92% and 72.2%, respectively, based on 102 porcine diarrhea samples using RT-PCR as gold standard. These results suggested that the oligonucleotide microarray system in this study be probably more reliable and reproducible means for detecting porcine enteric viruses and that it could be of substantial use in routine diagnostic laboratories.
Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.