연돌 효과를 이용한 태양열 굴뚝의 자연환기 성능에 관한 연구 (A Study on the Performance of Natural Ventilation of Solar Chimney Using Stack Effect)

  • 조성우;이재윤
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.35-43
    • /
    • 2001
  • The results of numerical simulation on the performance of a solar chimney system in building are described. The inside surface temperature of four walls within the solar chimney arc calculated with solar radiation and outdoor temperature in summer. The air within the solar chimney is heated by conduction, convection and radiation. Air temperature distribution from the bottom to the top and outlet air temperature can be obtained by solving energy balance equation. Since the buoyance or stack effect is affected by temperature difference between the bottom and the top within the solar chimney. It is evaluated using inlet and outlet temperatures. It is expected that natural ventilation by the solar chimney of witch the height is 7.8m and the cross sectional area is $4.93m^2$ can provide about $6400m^3/h$ on sunny day.

  • PDF

무창 분만 ${\cdot}$ 자돈사 환기 형태가 돈사내 환경에 미치는 영향 (Effects of Ventilation Types on Interior Environment of the Enclosed Farrowing-Nursery Pig House)

  • 유용희;송준익;강희설;전병수;김태일;김형호
    • 한국축산시설환경학회지
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 2002
  • This study was conducted to collect basic data about the effects of ventilation types on the interior environment of the enclosed farrowing-nursery pig house in Anseong, Icheon and Jeungpyong. Surveyed ventilation types in the enclosed farrowing-nursery pig house are classified in to 4 types. In V1 type, air enters through a planar slot inlet placed on the juncture of the entering wall and exit through the chimney fan outlet; in V2 type, air enters through a perforated ceiling inlet and exits chimney fan outlet(V2); in V3 type, air enters through a circular duct inlet and exit chimney fan outlet(V3); in V4 type, enters through a circular duct inlet and exits side wall exhaust fan outlet(V4). Temperature, relative humidity, air velocity and ammonia concentration($NH_3$) were measured in the interior of swine building in the summer. Interior temperature was not remarkably different in all ventilation types in this study. However, temperature of the V4 was somewhat lower than that of the other types. Air velocity of the V4 was higher and $NH_3$ concentration of the V4 was lower than those of other ventilation types. It is suggested that the V4 ventilation type be applicable in the enclosed farrowing-nursery pig house in Korea.

  • PDF

하나로 원형 조사공의 안내관 유동특성 (Flow Characteristics for Guide Tube of Circular Irradiation Hole in HANARO)

  • 박용철;우종섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1835-1840
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum,. rises up through the grid plate and the core channel and comes out from the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by a jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the guide jet is suppressed under the top of the chimney after modifying the orifice diameter of 37.5 mm to 31 mm.

  • PDF

저온기 육용계사의 적정 환기체계 구명

  • 이덕수;나재천;최희철;송준익;이상진;김형호
    • 한국가금학회:학술대회논문집
    • /
    • 한국가금학회 2002년도 가을 학술발표논문집
    • /
    • pp.108-109
    • /
    • 2002
  • 환기체계별 내부환경 조사에서 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 NH$_3$ 농도 4.2ppm으로 윈치창 입기방식보다 유리하였고, 사육 성적에서는 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 일당 증체량 45.6g, 사료요구율 1.71, 수당 연료비 35.4원으로 다른 환기방식보다 우수하였으며, 입기관 길이별 풍속은 4m 가 1m 입기관보다 공기가 고루 퍼져가는 경향이었고 지점별 계사내 온도는 입기관 입기방식이 5.9 ~ 7.7$^{\circ}C$(평균 7.$0^{\circ}C$) 높아 연료절감 효과가 기대되었다.

  • PDF

하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석 (The Analytic Analysis of Suppressing Jet Flow at Guide Tube of Circular Irradiation Hole in HANARO)

  • 박용철;우상익
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.214-219
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve m (12 m) depth of the reactor pool and cold by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and exit through the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be Quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to study the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, about fourteen kilogram per second (14 kg/s) suppressed the guide tube jet and met the design cooling flow rate in a circular flow tube, and that the fission moly target cooling flow rate met the minimum flow rate to cool the target.

  • PDF

하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석 (THE ANALYTIC ANALYSIS OF SUPPRESSING JET FLOW AT GUIDE TUBE OF CIRCULAR IRRADIATION HOLE IN HANARO)

  • 박용철;우상익
    • 한국전산유체공학회지
    • /
    • 제10권2호
    • /
    • pp.1-6
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed af inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and comes out from the outlet of chimney. A fission moly guide tube is extended from the reactor core to the top of the reactor chimney for easily loading a fission moly target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, reduced to about fourteen kilogram per second (14 kg/s) from the original flow rate of sixteen point three kilogram per second (16.3 kg/s) did not show the guide tube jet.

무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사 (Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2004
  • 본 연구는 국내의 있는 무창 분만ㆍ자돈사에 대하여 환기시스템 정립의 기초자료를 수집하고자 수행하였다. 측벽상단입기 지붕굴뚝배기, 천공천장입기 지붕굴뚝배기, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기의 4종류 무창분만ㆍ자돈사 환기 형태에 대하여 조사하였다. 겨울철 돈사 내 온도, 습도, 공기유속, 암모니아가스 농도의 환경상태를 조사하였다. 겨울철 각 환기 형태별 돈사 내 온도는 환기형태에 따른 온도의 차이는 없었다. 공기유속은 측벽덕트입기 측벽배기가 다른 환기 형태보다 높은 공기 유속이 있었다. 돈사 공간내 각 환기형태별 공기유동은 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기 환기형태가 비교적 다른 환기 시스템에 비교하여 원활한 공기유동이 있는 것으로 나타났다. 암모니아(NH$_3$) 농도도 다른 환기형태보다 측벽덕트입기 측벽배기가 낮은 경향을 보였다. 따라서, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기가 국내의 무창 분만ㆍ자돈사 환기방식에 적용할 수 있을 것으로 판단되었다.

  • PDF

육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구 (Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea)

  • 송준익;유용희;정종원;김태일;최희철;강희설;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권2호
    • /
    • pp.93-100
    • /
    • 2004
  • 본 연구는 우리나라에 건축되어져 있는 개방식 육성$\cdot$비육돈사나 무창식 육성$\cdot$비육돈사에 대한 효율 비교분석 연구가 없는 실정으로 개방식 육성$\cdot$비육돈사와 무창식 육성$\cdot$비육돈사의 환경효율을 검증하고자 하였다. 겨울철과 여름철로 나누어 실시한 실험결과는 다음과 같다. 1. 무창식 육성 비육돈사는 외부의 기온 변화가 심하더라도 돈사내부의 온도는 외부기온의 영향을 받지 않고 여름철 $31.8\~33.8^{\circ}C$, 겨울철 $17.9\~19.5^{\circ}C$를 유지하였으나 개방식 육성$\cdot$비육돈사는 여름철 32.1$\~$32.9, 겨울철 $15.8\~16.7^{\circ}C$를 유지하여 온도효율이 낮았다. 2. G2, G4 육성$\cdot$비육돈사는 돼지생활 공간(하부) 지점에서의 공기유속은 겨울철 최소환기($5\%$) 수준으로 하였을 때 0.2$\~$0.3 m/s 였으며, 여름철 최대환기($95\%$) 수준에서는 0.5$\~$0.6 m/s로 분포되어 여름철 및 겨울철의 육성$\cdot$비육돈사내 공기유속이 G1, G3 육성$\cdot$비육돈사보다 양호하였다. 3. 암모니아 농도를 측정한 바 G2, G4 육성$\cdot$비육돈사는 여름철 13.3$\~$16.6 ppm, 겨울철14.0$\~$~14.6 ppm으로 측정되었으며, G1, G3 육성$\cdot$비육돈사는 여름철 14.6$\~$20.3 ppm, 겨울철 20.3$\~$25 ppm을 유지하여 G1, G3 육성$\cdot$비육 돈사보다는 낮게 나타났다.

  • PDF