• 제목/요약/키워드: chemical leak

검색결과 129건 처리시간 0.028초

국내 안전등급 배관에 대한 손상사례 분석 (Piping Failure Analysis In Domestic Nuclear Safety Piping System)

  • 최선영;최영환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

가속기 저장링 삽입장치 진공 챔버의 용접 (The welding Characteristics of the Insertion Device Vacuum Chamber of PLS Storage Ring)

  • 최만호;한영진;김창균;정진화;권영각
    • Journal of Welding and Joining
    • /
    • 제17권4호
    • /
    • pp.32-38
    • /
    • 1999
  • PAL(Pohang Accelerator Laboratory) designed and manufactured a 5m-long straight vacuum chamber to adopt U7 undulator that is the first insertion device. Top and bottom plates of the vacuum chamber were made of Al alloy A5083-H321, and welded together by the GTAW welding. The leak rate is less than 1×{TEX}$10^{-10}${/TEX} torr·ℓ/s with negligible welding deformation. The pressure has been maintained below {TEX}$10^{-10}${/TEX} torr after installation. This paper reports the welding process and the method applied to achieve ultimate vacuum performance and t satisfy integrity of welds.

  • PDF

독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 - (A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia -)

  • 윤영삼;조문식;김기준;박연신;황동건;윤준헌;최경희
    • 한국위험물학회지
    • /
    • 제2권1호
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구 (Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis)

  • 고재선;박선영;김효
    • 한국가스학회지
    • /
    • 제12권3호
    • /
    • pp.56-63
    • /
    • 2008
  • 본 연구에서는 1991년부터 최근까지 16년간 발생된 3,593건의 가스사고[천연가스(NG) 및 액화석유가스(LPG)]사례를 수집하여 Database를 구축하였으며, 이를 근거로 사고의 발생건수를 형태 및 원인별로 분석하였다. 분석결과를 살펴보면 사고의 형태로는 누출, 폭발, 그리고 화재의 순서로 많이 발생하였다. 사고발생위치로는 화재는 밸브부위에서, 폭발은 호스부위에서, 그리고 누출은 배관부근에서 가스사고가 많이 발생한 것으로 나타났다. 또한 화재, 폭발, 누출의 각각의 경우에 Poisson 분석법을 적용하여 향후 5년 이내의 화재, 폭발 및 누출에 대한 가장 가능성이 높은 발생확률을 예측하였다. 향후 본 연구에서 구축한 국내가스사고 Database를 매년 지속적으로 보완 개정을 하면 국내 가스사고 예측에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있어 효과적인 가스안전관리 대책수립에 기여할 것으로 기대된다.

  • PDF

가스의 배경 온도 차이(방사율)가 OGI(Optical Gas Image)의 선명도에 미치는 영향 (Effects of Gas Background Temperature Difference(Emissivity) on OGI(Optical Gas Image) Clarity)

  • 박수리;한상욱;김병직;홍철재
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.1-8
    • /
    • 2017
  • 현재 산업현장의 가스 안전관리는 접촉식은 LDAR(Leak Detection and Repair), 비접촉식은 레이저 메탄검지기와 IR 카메라를 사용하고 있다. LDAR 방식은 전체 관리를 하는데 많은 인력과 소요시간이 들고, 관리자가 측정을 위해 가까이 접근해야 하므로 안전의 위협을 받을 수 있어 비접촉식이 더 효율적이다. 비접촉식에서 IR(infrared)을 이용한 가스 측정 방안에 대한 연구가 주목받고 있다. 산업 가스 중 메탄가스를 활용하여 측정 거리에 따라 가스 분출량을 변화시켜 OGI(optical gas image)를 촬영하였다. 본 논문은 가스의 배경온도차이가 OGI 의 선명도에 미치는 영향을 확인하기 위한 실험이다. OGI를 통해 가스의 구름모형을 정확하고, 선명하게 보기 위하여 배경온도 조절판을 제작하였다. 배경온도 조절판을 통해 배경온도와 대기온도 차이가 ${\Delta}T0^{\circ}C$일 때 보다 ${\Delta}T-6^{\circ}C$ 차이의 낮은 온도 조건으로 OGI 촬영을 한 결과가 육안을 확인하였을 때 더 선명한 차이가 나타났다. 선명도 차이의 객관성을 부여하기 위하여 추가로 MATLAB 의 RGB 분석법으로 확인한 결과, ${\Delta}T$$-6^{\circ}C$ 일 경우 RGB 값의 수치가 약 20% 낮게 나왔다. 배경온도가 대기온도보다 $-6^{\circ}C$ 낮을 때 더 선명하게 보이는 것은 총 복사법칙으로 설명이 가능하다. 가스의 배경온도가 대기온도에 비해 낮게 될 때 OGI 렌즈로 들어오는 가스의 복사에너지가 증가되어 가스가 더 선명하게 보이게 된다.

석유화학업종에서의 비산배출원 배출 특성 분석 (Analysis Characteristic of Non-point source in Petrochemical)

  • 구치완;안승효;마병철
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.45-51
    • /
    • 2022
  • 고정된 점배출원(Point source)에서 배출되는 오염물질을 포집하여 처리하는 기술은 꾸준히 개발되고 있으나, 비산배출원(Non-point source)의 경우 배출원이 다양하고, 일정하지 않아 배출물질 처리기술 및 실효성 있는 배출계수 등을 개발하는 것은 어려운 실정이다. 그렇지만, 비산배출원은 국내 배출량의 약 60%를 차지하고 있기 때문에 배출량 산정방법이 타당하여야 하며 이를 토대로 사업장은 배출저감기술 등을 개발하여야 한다. 이에, 본 연구에서는 배출량이 많은 석유화학업종을 대상으로 현재 사용되고 있는 배출계수의 실효성과 개선 방안 등을 제시하고자 한다. 이를 위하여, 전남 여수 소재 OO회사의 최근 5년간의 LDAR(Leak Detection And Repair)데이터를 분석하여 비산배출원의 배출특성 확인하였다. 그 결과, 유체 성상에 따른 배출 특성의 차이는 없으나 장치의 크기, 제조사별 특성의 차이가 있음을 확인할 수 있었다. 또한, 석유화학 업종에서 적용하는 자체 배출계수가 정유업종에 비해 크게 나타나는 것을 확인하였으며 이에 대한 개선방안 등을 제시하였다. 이러한 연구를 통하여 석유화학업종에 특화된 배출계수를 적용할 수 있으며 사업장 스스로 이를 획기적으로 감할 수 있는 기술을 개발하는데 기여할 것으로 기대한다.

국소마취하에 비디오 흉강경을 이용한 폐기포절제술 (Video-Assisted Thoracoscopic Bullectomy under Local Anesthesia)

  • 박만실
    • Journal of Chest Surgery
    • /
    • 제27권2호
    • /
    • pp.128-131
    • /
    • 1994
  • Recently we performed video-assisted thoracoscopic[VAT] examination and bullectomy under local anesthesia. Of the 10 patients undergoing VAT examination under local anesthesia with primary spontaneous pneumothorax, 8 patients underwent VAT bullectomy under local anesthesia using endo-GIA; 7 patients discharged within 24 hours after operation; 1 patient had an air leak after operation, so chemical pleurodesis with doxycycline was performed and discharged postoperative day 3. There have been no recurrence to date[60-120 days after operation]. We think spontaneous pneumothorax can be treated on an out-patient basis.

  • PDF