• Title/Summary/Keyword: chemical filter

Search Result 521, Processing Time 0.033 seconds

Treatment Study on the Combustion Gas of Medical Waste (의료폐기물 소각가스 처리에 관한 연구)

  • Lee, Sung-Jin;Seo, Man-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • Currently, medical waste stoker incinerator is widely used in the emission control technology of health-care risk waste and miscellaneous contaminated waste. In the past, wet type control technology was used to remove the major harmful gaseous contaminants of medical waste such as HCl, $NO_x,\;SO_2$, CO, DUST, Dioxin. However, the treatment cost for wastewater was high and it has a disadvantage for frozen system during winter season. Therefore, in order to obtain effective treatment, the dry type control technology was developed and widely used to remove the gaseous contaminants. In this study, pre-coated bag filter using hydrated lime, ($Ca(OH)_2$), was applied to the dry type control system and the optimum dose of hydrated lime was investigated. The treatment results showed that the dust collection rate was approximately 26.7%. Moreover, the HCl removal rate using pre-coated bag filter ($50mg/sm^3\;Ca(OH)_2$) was 13.52%, which was significantly higher than 3.26% obtained from conventional bag filter.

Characteristics analysis of Piezoelectric Thin Film SAW filter using Mg-doped GaN/Sapphire Structure (Mg-Doped GaN/Sapphire 구조로 제작된 압전 박막 SAW 필터의 특성분석)

  • 장철영;정은자;정영철;최현철;이정희;이용현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.759-762
    • /
    • 2003
  • The epitaxially grown Mg-doped GaN thin film was prepared by MOCVD (Metal Organic Chemical Vapor Deposition) for a SAW(Surface Acoustic Wave) filter. Mg-doped GaN thin film had enough properties for a SAW filter which include crystallinity and morphology. The surface morphology and crystalline of the Mg-doped GaN thin films were characterized using AFM and an X-ray rocking curve. The SAW filter, which was fabricated by lift-off process and frequency response, was measured by HP 8753C network analyzer. Center frequency was 96.687 MHz and SAW velocity was 5801 m/s when wavelength(λ) was 60${\mu}{\textrm}{m}$. Insertion loss was over -10 dB, Q was factor over 200, and side lobe attenuation was over 22 dB which was suitable for use as a SAW filter. Electro-mechanical coupling coefficient (k$^2$) was calculated from the measured data. k$^2$ was from 1 % to 1.44 %. The fabricated SAW filter using Mg-doped GaN/sapphire structure has good qualities as a filter and will be used as a SAW filter for operating RF frequency.

  • PDF

Optimal Design Study for Development of Washable Faucet Assembly Housing Including Filtration Filter (여과필터를 포함한 세척이 가능한 수도꼭지 어셈블리 하우징 개발을 위한 최적설계 연구)

  • Son, In-Soo;Bae, Sang-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.581-587
    • /
    • 2021
  • In recent years, contamination of drinking water sources has emerged as a serious social problem, such as a large number of impurities in tap water or groundwater or the supply of suitable water due to rust of pipes. Although the government and public institutions are implementing various measures to protect water sources, they cannot improve water quality in a short period of time because of the enormous cost involved. Therefore, in recent years, preference has been given to a device that converts tap water, which is hard water, into soft water by installing a separate water softener at the faucet from which tap water is discharged. However, the existing filtration device has a problem that filtration performance is gradually lowered when impurities accumulate in the filter, requiring continuous filter replacement. In this study, the optimal design of the filter housing was performed to develop a water softener that can be washed when impurities accumulate on the filter inside the water softener connected to the faucet. For optimal design of the filter housing, fluid and fluid-structural interaction analysis were performed on the design pressure to determine the shape and thickness of the housing, and design review was performed through prototype.

Effects of Consumable on STI-CMP Process (STI-CMP 공정에서 Consumable의 영향)

  • Kim, Sang-Yong;Park, Sung-Woo;Jeong, So-Young;Lee, Woo-Sun;Kim, Chang-Il;Chang, Eui-Goo;Seo, Yong-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.185-188
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process is widely used for global planarization of inter-metal dielectric (IMD) layer and inter-layer dielectric (ILD) for deep sub-micron technology. However, as the IMD and ILD layer gets thinner, defects such as micro-scratch lead to severe circuit failure, which affect yield. In this paper, for the improvement of CMP process, deionized water (DIW) pressure, purified $N_2 \; (PN_2)$ gas, slurry filter and high spray bar were installed. Our experimental results show that DIW pressure and $PN_2$ gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. Also, the filter installation in CMP polisher could reduce defects after CMP process, it is shown that slurry filter plays an important role in determining consumable pad lifetime. The filter lifetime is dominated by the defects. However, the slurry filter is impossible to prevent defect-causing particles perfectly. Thus, we suggest that it is necessary to install the high spray bar of de-ionized water (DIW) with high pressure, to overcome the weak-point of slurry filter. Finally, we could expect the improvements of throughput, yield and stability in the ULSI fabrication process.

  • PDF

Preparation of Zeolite Membranes on Papers or Fibers (종이나 섬유를 지지체로 이용한 제올라이트 박막의 제조)

  • Song, Kyeong-Keun;Ha, Kwang
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.691-695
    • /
    • 2005
  • Zeolite membranes on various supports such as filter paper, cotton fiber, and glass fiber filter were prepared by secondary growth hydrothermal synthesis. First, zeolite NaA (${\approx}0.5{\mu}m$) and silicalite-1 (${\approx}0.2{\mu}m$) crystals were synthesized as zeolite seed crystals, and they were attached to the surfaces of the supports via chemical bonding. Zeolite NaA or silicalite-1 membranes could be synthesized on the supports coated with the seed crystals. The prepared zeolite membranes were observed by scanning electron microscope and analyzed by X-ray diffraction.

Thermally Stable Photoreactive Polymers as a Color Filter Resist Bearing Acrylate and Cinnamate Double Bonds

  • Cho, Seung-Hyun;Lim, Hyun-Soon;Jeon, Byung-Kuk;Ko, Jung-Min;Lee, Jun-Young;Ki, Whan-Gun
    • Macromolecular Research
    • /
    • v.16 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • Photoreactive polymers as a color filter resist containing both photoreactive acrylate and cinnamate double bonds were synthesized usin two step reactions. The chemical structures of the synthesized polymers were confirmed by $^1H$-NMR and FT-IR spectroscopy. The photoreactive polymers were quite soluble in most common organic solvents and produced excellent quality thin films by spin-coating. The photocuring kinetics of the acrylate and cinnamate double bonds were examined by FT-IR and UV- Vis spectroscopy, which confirmed the excellent photoreactivity of both the acrylate and cinnamate double bonds in the polymers. Upon UV irradiation, photocuring was almost completed within approximately 5 min, irrespective of the type of the prepolymers. The polymers also exhibited superior thermal stability, showing little change in transmittance in the visible region even after heating to $250^{\circ}C$ for one hour. Photolithographic micropatterns could be obtained with a resolution of a few microns.

HEPA Filter Tests Using PLS and Composite Nanospheres (PLS 및 복합 나노구체를 이용한 HEPA 필터 시험)

  • Hwang, Min-Jin;Sung, Dong Chan;Moon, Hee
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.357-362
    • /
    • 2013
  • Monodispersed polystyrene latex spheres (PLS) and PS-MPS/silica composite nanospheres were used to test high efficiency particulate air (HEPA) filters. Prior to filter tests, all nanospheres used in this work were characterized by measuring their average particle diameters and coefficients of variation (CV) for assessing them as artificial dusts. The average particle sizes of PLS and composite nanospheres could be well controlled in the range of 100~300 nm well by changing reaction temperature and the amount of a stabilizer during emulsion polymerization. The CV of all nanospheres were also in the range of 3~7%, lower than 15% that is the criterion for monodispersed particle distributions. Furthermore the results of HEPA filter tests show that all nanospheres used were quite proper as artificial dusts for testing air filters.

The efficiency variation of UF(tubular)/RO(spiral wound) process using acrylic wastewater treated by different pretreatment processes (아크릴 폐수의 전처리공정에 따른 UF(tubular)/RO(spiral wound) 공정의 성능변화)

  • Lee, Kwang-Hyun;Han, Sung-Bum;Choi, Dae-Woong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.387-394
    • /
    • 2002
  • The efficiency variation of UF(tubular)/RO(spiral wound) process using acrylic wastewater treated by photo-catalyst pretreatment and coagulant-filter-neutralization pretreatment processes were discussed wit the variation of appled pressure and temperature. Ultrafiltration tubular module using acrylic wastewater treated by photo-catalyst pretreatment and coagulant-filter-neutralization pretreatment processes was shown that COD and T-N were not highly affected with the variation of appled pressure and temperature. It was shown that removal efficiency of COD and T-N was low. Removal efficiency of TDS and turbidity with ultrafiltration tubular module was better with the acrylic wastewater by photo-catalyst pretreatment than acrylic wastewater by coagulant-filter-neutralization pretreatment. T-N and TDS were shown high removal efficiency in reverse osmosis membrane process.

Application of brass scrubber filter with copper hydroxide nanocomposite structure for phosphate removal

  • Hong, Ki-Ho;Yoo, In-Sang;Kim, Sae-Hoon;Chang, Duk;Sunwoo, Young;Kim, Dae-Gun
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.199-204
    • /
    • 2015
  • In this study, a novel phosphorus removal filter made of brass scrubber with higher porosity of over 96% was fabricated and evaluated. The brass scrubber was surface-modified to form copper hydroxide on the surface of the brass, which could be a phosphate removal filter for advanced wastewater treatment because the phosphates could be removed by the ion exchange with hydroxyl ions of copper hydroxide. The evaluation of phosphate removal was performed under the conditions of the batch type in wastewater and continuous type through filters. Filter recycling was also evaluated with retreatment of the surface modification process. The phosphate was rapidly removed within a very shorter contact time by the surface-modified brass scrubber filter, and the phosphate mass of 1.57 mg was removed per gram of the filter. The possibility of this surface-modified brass scrubber filter for phosphorus removal was shown without undesirable sludge production of existing chemical phosphorus removal techniques, and we feel that it would be very meaningful as a new wastewater treatment.

Preparation and Characterization of Polyurethane Waterproof Coatings Containing Fly Ash

  • Lee, Sung-Il;Kim, Duk-Bae;Yang, Go-Su;Kim, Wan-Young;Byoun, Youn-Seop;Lee, Youn-Sik
    • Elastomers and Composites
    • /
    • v.38 no.3
    • /
    • pp.243-250
    • /
    • 2003
  • Polyurethane waterproof (PW) coatings are increasingly demanded in Korea for repairing cracks on old building roofs and construction of many sporting facilities. Calcium carbonate, a common filler, is incorporated in PW compositions. In this study, PW coatings were prepared by substituting a part of calcium carbonate with fly ash. The maximum amounts of calcium carbonate which can be substituted by fly ash obtained in the cyclone and bag filter dust collectors were 20 and 10%, respectively. It was found that the curing rate of PWs ran be controlled by varying the amount of Pb-octoate catalyst. The elongations at break as well as tensile strength and tear strength of PW coatings containing fly ash could also be adjusted such that their values were comparable to those of a standard PW coating by varying relative amounts of some components. However, the amount of cadmium, mercury, and lead leached from PW coatings containing fly ash obtained from the bag filter collector exceeded the respective allowed upper limits, mainly due to the initial high contents of them in the fly ash. On the other hand, PW coatings containing fly ash obtained from the cyclone collector exhibited better mechanical properties and did not release any significant amounts of the heavy metals. Thus, it was concluded that PW coatings containing fly ash can be utilized for practical applications as long as an appropriate fly ash is used.