• 제목/요약/키워드: chemical defense

검색결과 395건 처리시간 0.026초

Nanosecond Gated Raman Spectroscopy for Standoff Detection of Hazardous Materials

  • Chung, Jin Hyuk;Cho, Soo Gyeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권12호
    • /
    • pp.3547-3552
    • /
    • 2014
  • Laser Raman spectroscopy is one of the most powerful technologies for standoff detection of hazardous materials including explosives. Supported by recent development of laser and sensitive ICCD camera, the technology can identify trace amount of unknown substances in a distance. Using this concept, we built a standoff detection system, in which nanosecond pulse laser and nanosecond gating ICCD technique were delicately devised to avoid the large background noise which suppressed weak Raman signals from the target sample. In standoff detection of explosives which have large kill radius, one of the most important technical issues is the detection distance from the target. Hence, we focused to increase the detection distance up to 54 m by careful optimization of optics and laser settings. The Raman spectra of hazardous materials observed at the distance of 54 m were fully identifiable. We succeeded to detect and identify eleven hazardous materials of liquid or solid particles, which were either explosives or chemical substances used frequently in chemical plants. We also performed experiments to establish the limit of detection (LOD) of HMX at 10 m, which was estimated to be 6 mg.

Man-in-Simulant Test(MIST) 실험을 위한 다양한 흡착제의 화학증기 흡착용 샘플러 제작 (Facile Fabrication of Chemical Vapor Samplers with Various Adsorbents for Man-in-Simulant Test(MIST))

  • 정현숙;이규원;최근섭;박명규;이해완
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.129-134
    • /
    • 2014
  • We have developed a cost-effective and facile method to manufacture a pouch-type chemical vapor sampler. Originally, the sampler was developed by U. S. Army Natick Soldier Research, Development, and Engineering Center(NSRDEC) to determine the protective capability of individual protective ensembles or Man-in-Simulant Test (MIST). They used a selectively permeable high density polyethylene(HDPE) as front membrane and aluminum/ Nylon barrier film as an impermeable back sheet in order to mimic the actual adsorption process that occurs when the skin is exposed to chemical weapons. However, it costs over twenty dollars per sampler and the minimum of quantity is 2500 per order. In addition, it is inconvenient to employ a variety of adsorbents into the sampler, which could prevent MIST researchers to do various tests for development of MIST methodologies. Here, we report the simple method to manufacture the sampler in a laboratory scale. All the materials we used are easily obtainable and inexpensive. In addition, all the procedures we perform are generally known. We used methyl salicylate(MeS) vapor to be adsorbed into the sampler and employed several different adsorbents to evaluate the performance of samplers. The results obtained by home-made samplers and commercially avaliable one showed no significant differences. Also, MeS vapor was selectively adsorbed into the sampler depending on adsorbents. We conclude that home-made samplers are capable of collecting any kind of chemical vapor for a variety of purposes.

GC-TSQ CI 분석법을 이용한 제32차 OPCW 숙련도 시험 시료 분석 연구 (Analysis Study on 32nd OPCW Proficiency Test Sample with GC-TSQ CI)

  • 김현석;정창희;이용한
    • 한국군사과학기술학회지
    • /
    • 제17권6호
    • /
    • pp.828-835
    • /
    • 2014
  • GC-TSQ CI technique was applied for analysis of samples for the $32^{nd}$ OPCW proficiency test. Eight chemical weapon convention(CWC) related chemicals were identified by product ion mode analysis with GC-TSQ in the samples. Choice of specific precursor ion made it possible to supply selective total ion chromatograms(TICs) of target molecule. GC-TSQ CI anaylsis technique was useful method for chemical warfare agent verification because analysis selectivity was improved by choice of mother molecule as precursor ion and gave mass spectra.

Discrimination of Bacillus anthracis Spores by Direct in-situ Analysis of Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight Mass Spectrometry

  • Jeong, Young-Su;Lee, Jonghee;Kim, Seong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2635-2639
    • /
    • 2013
  • The rapid and accurate identification of biological agents is a critical step in the case of bio-terror and biological warfare attacks. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been widely used for the identification of microorganisms. In this study, we describe a method for the rapid and accurate discrimination of Bacillus anthracis spores using MALDI-TOF MS. Our direct in-situ analysis of MALDI-TOF MS does not involve subsequent high-resolution mass analyses and sample preparation steps. This method allowed the detection of species-specific biomarkers from each Bacillus spores. Especially, B. anthracis spores had specific biomarker peaks at 2503, 3089, 3376, 6684, 6698, 6753, and 6840 m/z. Cluster and PCA analyses of the mass spectra of Bacillus spores revealed distinctively separated clusters and within-groups similarity. Therefore, we believe that this method is effective in the real-time identification of biological warfare agents such as B. anthracis as well as other microorganisms in the field.

Standoff Raman Spectroscopic Detection of Explosive Molecules

  • Chung, Jin Hyuk;Cho, Soo Gyeong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1668-1672
    • /
    • 2013
  • We developed a standoff Raman detection system for explosive molecules (EMs). Our system was composed of reflective telescope with 310 mm diameter lens, 532 nm pulse laser, and Intensified Charge-Coupled Device (ICCD) camera. In order to remove huge background noise coming from ambient light, laser pulses with nanosecond time width were fired to target sample and ICCD was gated to open only during the time when the scattered Raman signal from the sample arrived at ICCD camera. We performed standoff experiments with military EMs by putting the detector at 10, 20 and 30 m away from the source. The standoff results were compared with the confocal Raman results. Based on our standoff experiments, we were able to observe the peaks in the range of 1200 and $1600cm^{-1}$, where vibrational modes of nitro groups were appeared. The wave numbers and shapes of these peaks may serve as good references in detecting and identifying various EMs.

원거리 화학영상탐지시스템의 시야각에 대한 연구 (A Study on the Field of View of the Remote FTIR Chemical Imaging Detection System)

  • 이종민;강영일;김주현
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.122-128
    • /
    • 2014
  • Remote fourier transform infrared(FTIR) chemical imaging detection system allows detection and identification of gases in the atmosphere from long distances. In this paper, the appropriate field of view(FOV) of the FTIR imaging system was examined and the main performance of the system for the interferometer was described. For the determination of the FOV, simulations of gas dispersion range were performed with the NBC reporting and modeling software(NBC-RAMS) developed by ADD. As a result, minimum 192 mrad of FOV was required for the remote FTIR imaging system to visualize chemical warfare agents dispersed in several hundred meters. At the same time, 0.75 mrad of instantaneous field of view(IFOV) for a linear interferometer proper to take a FOV for the chemical agent imaging.

준실시간 소형 풍동 시스템을 이용한 화학작용제(HD) 증발특성 연구 (A Near Real-Time Wind Tunnel System for Studying Evaporation of Chemical Agents(HD))

  • 가동하;정현숙;서지윤;이준오;이해완
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.135-140
    • /
    • 2019
  • Upon chemical agent release, it is of importance to study the characteristic persistence and evaporation of chemical agents from surfaces for the prediction of dispersion hazard. We have recently developed a fast and near real-time wind tunnel system proving the controlled environment(air flow, temperature, and humidity), continuously collects agent vapor and analyzes it. A thermal sorber/desorber is unnecessary to collect the vapor in the system we have developed. Instead, a tandem thermal sorber collects the vapor, which is then directly transferred to a fast gas chromatography(GC) for analysis. As a proof of concept, the evaporation of sulfur mustard agent(HD) was studied from glass, sand and concrete. The results were in an excellent agreement with those obtained from the conventional wind tunnel system.

Sulfur Mustard(HD)의 가수분해 (Hydrolysis of Sulfur Mustard(HD) in Water)

  • 이용한;이종철;최수;홍대식
    • Korean Chemical Engineering Research
    • /
    • 제45권3호
    • /
    • pp.291-297
    • /
    • 2007
  • 수포작용제의 일종인 sulfur mustard(HD, bis 2-chloroethylsulfide)를 무해한 물질로 전환하기 위한 공정 운영조건을 찾기 위하여 물에 의한 HD 가수분해 반응을 연구하고 분석절차를 수립하였다. 반응은 2단계로 진행하였다. 먼저, HD 10~20 wt%를 $90^{\circ}C$ 물에서 2시간 동안 가수분해 한 후 상온에서 가성소다 수용액(2.1 당량)을 주입하면서 반응시간에 따른 HD의 농도변화를 측정하였다. 이 실험조건에서 HD의 분해효율은 99.99% 이상 이었으며 가수분해 후의 최종 분해물질은 thiodiglycol 68 wt%, 1,2-bis(2-hydroxyethylthio)ethane 8 wt% 및 bis(2-hydroxyethylthioethyl)ether 24 wt% 이었다.