• Title/Summary/Keyword: chemical cleaning

Search Result 528, Processing Time 0.03 seconds

A Study on the Fabrication of Multi-Walled Nanotubes (MWCNT) Based Thin Film and Chemical Sensor Operation Characteristics (Multi-Walled Carbon Nanotubes (MWCNT) 인쇄박막의 제작과 화학센서 동작 특성에 관한 연구)

  • Noh, Jae Ha;Choi, Junseck;Ko, Dongwan;Seo, Joonyoung;Lee, Sangtae;Jung, Jung-Yeul;Chang, Jiho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.181-185
    • /
    • 2020
  • Hazardous and noxious substance (HNS) detection sensors were fabricated using multi-walled carbon nanotubes (MWCNTs) and various binder materials for ion batteries. To obtain uniformly printed films, the printing precision according to the substrate cleaning method was monitored, and the printing paste mixing ratio was investigated. Binders were prepared using styrene butadiene rubber + carboxymethyl cellulose (SBR+CMC), polyvinylidene fluoride + n-methyl-2-pyrrolidene (PVDF+NMP), and mixed with MWCNTs. The surface morphology of the printed films was examined using an optical microscope and a scanning electron microscope, and their electrical properties are investigated using an I-V sourcemeter. Finally, sensing properties of MWCNT printed films were measured according to changes in the concentration of the chemical under the various applied voltages. In conclusion, the MWCNT printed films made of (SBR+CMC) were found to be feasible for application to the detection of hazardous and noxious chemicals spilled in seawater.

Transmembrane Pressure of Backwashing, Filtration/Relaxation and the Sinusoidal Flux Continuous Operation Modes for Submerged Plate Membrane (역세척, 여과/이완 및 사인파형 연속투과 운전방식에 따른 침지형 평막의 막간차압)

  • Kim, Jae Hyo;Kim, Eun Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.29 no.4
    • /
    • pp.216-222
    • /
    • 2019
  • In this study, permeation experiments were conducted using naturally circulating spherical beads, backwashable plate membrane and the air supplied from the bottom of the MBR. The activated sludge solution was maintained at 8,000 mg/L of MLSS and compared transmembrane pressure (TMP) with respect to FR (filtration and relaxation), FR/BW (filtration and relaxation/backwashing), SFCO (sinusoidal filtration continuous operation) and SFCO/BW (sinusoidal filtration continuous operation/backwashing). As the backwashing flux decreased from 47 to $14L/m^2{\cdot}hr$, the TMP increased generally, but the TMP of FR system increased significantly comparing with SFCO. In addition, the backwashing method reduced more TMP comparing to the cleaning method using spherical beads, and it was confirmed that the operation method using the spherical beads and the backwashing simultaneously is more effective than each method.

A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process (화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구)

  • Shin, Sung-Hoon;Jung, Jong-Tai;Cho, Yong-Chul
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

Characteristics of Humidifier Disinfectant-like Products Containing NaDCC (sodium dichloroisocyanurate) and Their Use in Hospitals (NaDCC (sodium dichloroisocyanurate) 성분 가습기살균제 유사제품의 특성과 의료기관에서의 사용 사례)

  • Jo, Eun-Kyung;Han, Kyunghee;Ju, Min Jae;Yang, Wonho;Cho, Yoon-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.495-503
    • /
    • 2020
  • Objective: This study aimed to compare the characteristics of humidifier disinfectant-like products (HD-like products) and humidifier disinfectant products (HD products) and introduce actual cases of the usage of HD-like products in hospitals based on an on-site investigation. Methods: The characteristics, chemical components, and usage of HD-like products (Hichlor or Biospot) and HD products (N-with) containing NaDCC (sodium dichloroisocyanurate) were compared. In the process of conducting the on-site investigation, four hospitals were identified as previously using HD-like products. Each on-site investigation to identify the use of HD-like products was composed of four parts: 1) hospital infection control guidelines, 2) manual for humidifiers in patient's rooms, 3) interviews with nursing staff, infection managers, and purchase managers, 4) searching on the product purchase system. Results: Although HD-like products (Hichlor and Biospot) and HD products (N-with) were sold for different usage purposes, they were all white-colored and coin-shaped foaming tablets with the same chemical component, NaDCC. The manual for using HD-like products and HD products was similar (inserting the tablet in a humidifier container with water). Among the four hospitals, one had used Hichlor in the same manner as HD (N-with) by inserting a tablet in 1L of water in a filled humidifier container and Biospot as a kind of detergent for humidifier container cleaning. Another two hospitals had used Biospot and/or Aniosyme as a kind of detergent for humidifier container cleaning. The other hospital had used unknown product in the same manner as N-with, so we thus assumed it was either an HD products (N-with) or HD-like products (Hichlor, Biospot). Conclusion: This study raises the possibility of the development of adverse health effects similar to exposure to an HD-products when exposed to an HD-like products and the possibility of further use in other medical institutions or multi-use facilities. Therefore, an expansion of the investigation is needed in order to confirm whether there have been similar cases in the past.

Simultaneous Transfer and Patterning of CVD-Grown Graphene with No Polymeric Residues by Using a Metal Etch Mask

  • Jang, Mi;Jeong, Jin-Hyeok;Trung, T.Q.;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.642-642
    • /
    • 2013
  • Graphene, two dimensional single layer of carbon atoms, has tremendous attention due to its superior property such as high electron mobility, high thermal conductivity and optical transparency. Especially, chemical vapor deposition (CVD) grown graphene has been used as a promising material for high quality and large-scale graphene film. Unfortunately, although CVD-grown graphene has strong advantages, application of the CVD-grown graphene is limited due to ineffective transfer process that delivers the graphene onto a desired substrate by using polymer support layer such as PMMA(polymethyl methacrylate). The transferred CVD-grown graphene has serious drawback due to remaining polymeric residues generated during transfer process, which induces the poor physical and electrical characteristics by a p-doping effect and impurity scattering. To solve such issue incurred during polymer transfer process of CVD-grown graphene, various approaches including thermal annealing, chemical cleaning, mechanical cleaning have been tried but were not successful in getting rid of polymeric residues. On the other hand, lithographical patterning of graphene is an essential step in any form of microelectronic processing and most of conventional lithographic techniques employ photoresist for the definition of graphene patterns on substrates. But, application of photoresist is undesirable because of the presence of residual polymers that contaminate the graphene surface consistent with the effects generated during transfer process. Therefore, in order to fully utilize the excellent properties of CVD-grown graphene, new approach of transfer and patterning techniques which can avoid polymeric residue problem needs to be developed. In this work, we carried out transfer and patterning process simultaneously with no polymeric residue by using a metal etch mask. The patterned thin gold layer was deposited on CVD-grown graphene instead of photoresists in order to make much cleaner and smoother surface and then transferred onto a desired substrate with PMMA, which does not directly contact with graphene surface. We compare the surface properties and patterning morphology of graphene by scanning electron microscopy (SEM), atomic force microscopy(AFM) and Raman spectroscopy. Comparison with the effect of residual polymer and metal on performance of graphene FET will be discussed.

  • PDF

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

Effects of Pretreatment of Alkali-degreasing Solution for Cu Seed Layer (약알칼리탈지 용액에서의 구리 Seed 층의 전처리 효과)

  • Lee, Youn-Seoung;Kim, Sung-Soo;Rha, Sa-Kyun
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.1
    • /
    • pp.6-11
    • /
    • 2012
  • In order to understand a process of contaminants removal on surface of Cu seed layer (Cu seed/Ti/Si) by sputter deposition, we investigated the changed morphology and states of Cu seed surface after pretreatment in alkali degreasing Metex TS-40A solution according to dipping time. After TS-40A pretreatment, the surface morphology with clearer grains was observed by Field emission scanning electron microscope and the changed surface chemical states and impurities on surface of samples were checked by X-ray photoelectron spectroscopy. Dipping time in TS-40A solution had very little effect on surface of Cu seed layer. After pretreatment, much carbons and little oxygens on surface of Cu seed were eliminated and the decrease of peaks corresponded to O=C and $Cu(OH)_2$ was estimated. However, Si content (=silicate) was detected on sample surface. We think that the silicate impurity forms on Cu seed by chemical reaction of TS-40A solution included silicate component. By pretreatment of alkali degreasing Metex TS-40A solution, it showed an excellent effect in removal of O=C and $Cu(OH)_2$ on Cu seed layer, but the silicate was formed on surface of Cu seed. Therefore, another cleaning process such as acid cleaning is required for removal of this silicate in use of this alkali degreasing.

Cleaning Effects of Environmental-Friendly Washing Detergent on Milking Installation in Dairy Farms (젖소농가의 착유시설에 따른 친환경세제의 세척에 미치는 영향)

  • Kim, Chang-Hyun;Park, Joong-Kook
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.346-353
    • /
    • 2010
  • This study was conducted to determine cleaning effects of environmental-friendly washing detergent on milking installation in dairy farms. Milking machine, cooling machine and milking liner were washed by alkaline detergent and acid detergent for first three weeks and alkaline detergent and environmental~friendly detergent for next three weeks and the results get through microorganism and physico-chemistry analysis at the five district dairy farms different from environment. E-coli, coliform, fecal coliform, staphylococcus aureus, fecal streptococcus, prsudomonas aeruginosa and yersinia were not found in all of the dairy farms, and total colony counts were no difference compared with chemical detergent. The water for washing exceeded the determining acceptable level of nitrate nitrogen in the Anseong, Onyang and Cheonan and the remaining substance of washed water was also high levels. The cause of the result was that the level of nitrate nitrogen of water is basically high. Therefore, this study indicated that washing effect is no differences between environmental-friendly detergent and chemical detergent by washing for milking machine and cooling machine. Above all, producing high quality milk is to manage the water quality as well as using detergent.

A Study on Reactivity of ZnO-CuO Sorbent for Hot Gas Desulfurization (고온 연료가스 정제를 위한 ZnO-CuO 혼성탈황제의 반응 특성연구)

  • Jung, Yong-Kgil;Park, No-Kuk;Jun, Jin Hyuk;Lee, Jong-Dae;Ryu, Si-Ok;Lee, Tae-Jin
    • Clean Technology
    • /
    • v.9 no.4
    • /
    • pp.189-196
    • /
    • 2003
  • ZnO-CuO mixed sorbents for desulfurization in hot gas cleaning process Were prepared and investigation on their characteristics was performed in this study. The rate of sulfidation increased as the amount of copper oxide in the composite sorbent was raised. TPO experiments were carried out to investigate the characteristics of the regeneration of the sorbents with severa1 different ratios of Zno to CuO. Copper sulfate was formed at temperatures above $400^{\circ}C$, while it was decomposed by pyrolysis above $700^{\circ}C$. $SO_2$ slippage due to $CuSO_4$ was observed in the sorbent regenerated at temperatures above $600^{\circ}C$. However, it was not observed when regenerated above $700^{\circ}C$. It was confirmed in the ZnO-CuO mixed sorbent system that CuO suppressed the vaporization of ZnO on the one hand and Zno minimized the $SO_2$ slippage due to CuO on the other hand.

  • PDF

Chemical Resistance Characteristics of the Chlorinated Polyvinyl Chloride Microfiltration Flat-sheet Membrane with respect to Immersion Time (침지시간에 따른 Chlorinated Polyvinyl Chloride 정밀여과용 평막의 내화학적 특성)

  • Ryu, Jae-Sang;Son, Jae-Ik;Kim, Hee-Jun;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.324-332
    • /
    • 2009
  • This study aimed to measure chemical resistance properties of the microfiltration flat-sheet membrane made by Chlorinated Polyvinyl Chloride (CPVC) with respect to the immersed time. The solutions of effective chlorine 0.5 wt% NaClO, HCl 1 wt% and pH 4 buffer under acidic condition, NaOH 4 wt% and pH 10 buffer under alkine condition were used as widely applied chemicals for membrane washing. The CPVC membrane samples were immersed in the above chemical solutions during 1, 3, 5 and 10 days at 5, 25 and $50^{\circ}C$, respectively. After then, the tensile strength and elongation at break as the chemical durability for the samples were measured and evaluated. The tensile strength decreased within 5% at $5^{\circ}C$, but decreased up to 17% at 25 and $50^{\circ}C$ for 0.5 wt% NaClO solution mainly used for membrane cleaning. The chemical resistance of CPVC membrane was good enough for HCl 1 wt% and pH 4 buffer acid solutions, but the most vulnerable for NaOH 4 wt% solution.